Semiautomated registration using new markers for assessing the accuracy of a navigation system.

OBJECTIVES New markers are described that can be used for an improved registration procedure and for the exact comparison of navigation systems. The advantages of the markers are demonstrated, together with an automated segmentation algorithm for locating the centroid of the markers in image space. Compared to manual registration, this method shows an improved registration accuracy. MATERIALS AND METHODS The new markers are detected completely automatically within all scan images. This allows a semiautomatic registration, as a preregistration is performed via the algorithm. Furthermore, the exact coordinates within one scan slice are now determined with the calculation procedure. The calculated data from the preregistration were matched up with a manual preregistration and some reference data, so as to confirm the quality of this new algorithm. The accuracies of several manual and semiautomatic registrations were also compared. RESULTS The average deviation between the coordinates of the algorithm and the reference data (coordinate measuring machine) was 0.3 mm. The standard deviation amounted to 0.131 mm. Comparing several manual registrations with the reference data showed that the middle fiducial registration error (FRE) was between 0.7 and 2 mm. In comparison, the FRE remained constant at around 0.7 mm for the semiautomatic registration procedure. CONCLUSIONS The measured results show a significant improvement in the preregistration data using the new markers together with the algorithm. This improvement leads to a reproducible and more accurate registration. The combination of the new marker type with the automated segmentation algorithm minimizes the human error factor, and provides the opportunity to directly compare image-guided and robotic systems.

[1]  Calvin R. Maurer,et al.  Registration of head volume images using implantable fiducial markers , 1997, IEEE Transactions on Medical Imaging.

[2]  Shao Chin,et al.  Development of fluoroscopic registration in spinal neuronavigation , 2001, SPIE Medical Imaging.

[3]  Horst Stöcker,et al.  Taschenbuch mathematischer Formeln und moderner Verfahren (3. Aufl.) , 1995 .

[4]  Peter Kazanzides,et al.  An image-directed robotic system for precise orthopaedic surgery , 1994, IEEE Trans. Robotics Autom..

[5]  Benoit M. Dawant,et al.  Registration of 3-D images using weighted geometrical features , 1996, IEEE Trans. Medical Imaging.

[6]  Robert J. Maciunas,et al.  Registration of head CT images to physical space using multiple geometrical features , 1998, Medical Imaging.

[7]  A. Forbes Least-squares best-fit geometric elements. , 1991 .

[8]  Jay B. West,et al.  Fiducial Point Placement and the Accuracy of Point-based, Rigid Body Registration , 2001, Neurosurgery.

[9]  Benoit M. Dawant,et al.  Registration of CT and MR brain images using a combination of points and surfaces , 1995, Medical Imaging.

[10]  Aaron Fenster,et al.  Single-camera system for optically tracking freehand motion in 3D: experimental implementation and evaluation , 2001, SPIE Medical Imaging.

[11]  J. Fitzpatrick,et al.  Estimation of accuracy in localizing externally attached markers in multimodal volume head images , 1993 .

[12]  J. Robert Boston,et al.  Consequences of fiducial marker error on three-dimensional computer animation of the temporomandibular joint , 2001, SPIE Medical Imaging.

[13]  Jay B. West,et al.  Predicting error in rigid-body point-based registration , 1998, IEEE Transactions on Medical Imaging.

[14]  T Kanade,et al.  Techniques for fast and accurate intrasurgical registration. , 1995, Journal of image guided surgery.

[15]  C Schaller,et al.  Image guided microsurgery with a semifreehand neuronavigational device. , 1997, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[16]  Colin Studholme,et al.  Automated 3D Registration of Truncated MR and CT Images of the Head , 1995, BMVC.

[17]  Robert J. Maciunas,et al.  Registration of head volume images using implantable fiducial markers , 1997, IEEE Transactions on Medical Imaging.

[18]  Leibinger Kar,et al.  5394457 Device for marking body sites for medical examinations , 1995 .