Ultrasensitive and ultraselective impedimetric detection of Cr(VI) using crown ethers as high-affinity targeting receptors.

Detection of Cr(VI) by electrochemical methods generally focuses on noble-metal-modified electrodes in strong acid solution using voltammetric techniques. In this work, we report a new strategy to detect Cr(VI) as HCrO4(-) at pH 5.0 in drinking water using electrochemical impedance spectroscopy. The strategy is based on the high-affinity and specific binding of crown ethers (i.e., azacrown) to HCrO4(-), which forms sandwich complexes between them via hydrogen bonds and moiety interactions with K(+) captured by azacrown on its self-assembled Au electrode surface. This then blocks the access of redox probes (Fe(CN)6(3-/4-)) to the self-assembled Au electrode, further resulting in an increase in the electron transfer resistance. This method offers a detection limit of 0.0014 ppb Cr(VI) with a sensitivity of 4575.28 kΩ [log c (ppb)](-1) over the linear range of 1-100 ppb (R(2) = 0.994) at pH 5.0. In addition, the azacrown self-assembled Au electrode has good selectivity for Cr(VI) with good stability and low interferences. This approach can be performed on spiked Cr(VI) as well as real samples. To the best of our knowledge, this is the first example of electrochemical impedimetric sensing that allows ultrasensitive and ultraselective detection of Cr(VI).

[1]  M. Gardner,et al.  Determination of trace concentrations of hexavalent chromium. , 2002, The Analyst.

[2]  William R. Cullen,et al.  Arsenic speciation in the environment , 1989 .

[3]  C. Kao,et al.  Enhancement of electrokinetic remediation of hyper-Cr(VI) contaminated clay by zero-valent iron. , 2007, Journal of hazardous materials.

[4]  Aicheng Chen,et al.  Sensitive and selective electrochemical detection of chromium(VI) based on gold nanoparticle-decorated titania nanotube arrays. , 2014, The Analyst.

[5]  Min Wang,et al.  A study of nanostructured gold modified glassy carbon electrode for the determination of trace Cr(VI) , 2008 .

[6]  D. Mandler,et al.  Selective Determination of Cr(VI) by a Self-Assembled Monolayer-Based Electrode. , 1997, Analytical chemistry.

[7]  B. Tang,et al.  Rapid and sensitive spectrofluorimetric determination of trace amount of Cr(III) with o-vanillin-8-aminoquinoline. , 2004, Talanta.

[8]  M. K. Donais,et al.  Chromium speciation using an automated liquid handling system with inductively coupled plasma - mass spectrometric detection. , 1999, Talanta.

[9]  E. Wang,et al.  A novel Au-Ag-Pt three-electrode microchip sensing platform for chromium(VI) determination. , 2013, Analytica chimica acta.

[10]  R. Compton,et al.  Voltammetric determination of Chromium(VI) using a gold film modified carbon composite electrode , 2013 .

[11]  I. Tsuyumoto,et al.  X-ray fluorescence analysis of hexavalent chromium using Kβ satellite peak observed as counterpart of X-ray absorption near-edge structure pre-edge peak. , 2011, Analytical chemistry.

[12]  M. Pereira,et al.  Adsorptive stripping voltammetric measurements of chromium accumulation in mice organs using mercury film microelectrodes , 1997 .

[13]  A. Zouhri,et al.  Bulk Liquid Membrane for the Recovery of Chromium(VI) from a Hydrochloric Acid Medium Using Dicyclohexano-18-crown-6 as Extractant-Carrier , 1999 .

[14]  Aniruddha Ghosh,et al.  Removal of hexavalent chromium from water by adsorption on mosambi (Citrus limetta) peel , 2013, Research on Chemical Intermediates.

[15]  M. Toprak,et al.  Studies on the adsorption of chromium(VI) onto 3-Mercaptopropionic acid coated superparamagnetic iron oxide nanoparticles. , 2014, Journal of colloid and interface science.

[16]  Jianshe Liu,et al.  Electrochemical synthesis of silver nanoparticles-coated gold nanoporous film electrode and its application to amperometric detection for trace Cr(VI) , 2011 .

[17]  E. Guerra,et al.  Au dissolution during the anodic response of short-chain alkylthiols with polycrystalline Au electrodes , 2011 .

[18]  M. Bergamini,et al.  Development of a voltammetric sensor for chromium(VI) determination in wastewater sample , 2007 .

[19]  G. Shi,et al.  A Simple and Sensitive Method for the Amperometric Detection of Trace Chromium(VI) Based on Prussian Blue Modified Glassy Carbon Electrode , 2009 .

[20]  N. Koçak,et al.  Synthesis of a novel calix[4]azacrown ionophore and its extraction ability toward Cr(VI) , 2013, Journal of Inclusion Phenomena and Macrocyclic Chemistry.

[21]  E. Wang,et al.  Combining chemical reduction with an electrochemical technique for the simultaneous detection of Cr(vi), Pb(ii) and Cd(ii). , 2009, The Analyst.

[22]  Jonathan P. Metters,et al.  Electroanalytical sensing of chromium(III) and (VI) utilising gold screen printed macro electrodes. , 2012, The Analyst.

[23]  Shun Yu,et al.  Water Adsorption on ZnO(0001): Transition from Triangular Surface Structures to a Disordered Hydroxyl Terminated phase , 2010 .

[24]  A. Zouhri,et al.  The use of dicyclohexano 18 crown 6 as an extractant-carrier for the recovery of chromic acid , 1995 .

[25]  T. Maeder,et al.  Screen-printed electrodes for electroanalytical sensing, of chromium VI in strong acid media , 2014 .

[26]  A. Steel,et al.  Electrostatic interactions of redox cations with surface-immobilized and solution DNA. , 1999, Bioconjugate chemistry.

[27]  J. Cox,et al.  Self-assembled monolayers of crown ethers for solid phase extraction in flow-injection analysis , 2003 .

[28]  Graham de Ruiter,et al.  Selective optical recognition and quantification of parts per million levels of Cr(6+) in aqueous and organic media by immobilized polypyridyl complexes on glass. , 2008, Journal of the American Chemical Society.

[29]  Zhi-Xia Zheng,et al.  Cloud point extraction combined with high-performance liquid chromatography for speciation of chromium(III) and chromium(VI) in environmental sediment samples. , 2010, Journal of hazardous materials.

[30]  M. Jakubowska Hybrid signal processing in voltammetric determination of chromium(VI). , 2010, Journal of hazardous materials.

[31]  C. Lambert,et al.  Effect of electrode roughness on the capacitive behavior of self-assembled monolayers. , 2008, Analytical chemistry.

[32]  S. Balasubramanian,et al.  Determination of total chromium in tannery waste water by inductively coupled plasma-atomic emission spectrometry, flame atomic absorption spectrometry and UV-visible spectrophotometric methods. , 1999, Talanta.

[33]  Z. Xue,et al.  Improved Bi Film Wrapped Single Walled Carbon Nanotubes for Ultrasensitive Electrochemical Detection of Trace Cr(VI). , 2013, Electrochimica acta.

[34]  B. Jena,et al.  Highly sensitive and selective electrochemical detection of sub-ppb level chromium(VI) using nano-sized gold particle. , 2008, Talanta.

[35]  Mohamed Siaj,et al.  In vitro selection, characterization, and biosensing application of high-affinity cylindrospermopsin-targeting aptamers. , 2014, Analytical chemistry.

[36]  Yuehe Lin,et al.  Voltammetric detection of Cr(VI) with disposable screen-printed electrode modified with gold nanoparticles. , 2007, Environmental science & technology.

[37]  D. Reinhoudt,et al.  Recognition of Cations by Self-Assembled Monolayers of Crown Ethers , 1999 .

[38]  J. M. Bhatnagar,et al.  Selective anion recognition: Charged diaza crown ethers based electrochemical sensors for chromate ions , 2005 .

[39]  G. Shi,et al.  Nafion stabilized silver nanoparticles modified electrode and its application to Cr(VI) detection , 2011 .

[40]  Rashid O. Kadara,et al.  Graphite screen printed electrodes for the electrochemical sensing of chromium(VI). , 2010, The Analyst.

[41]  L. Qi,et al.  Determination of chromium(VI) by surface plasmon field-enhanced resonance light scattering. , 2007, Analytical chemistry.

[42]  Z. Xue,et al.  Flower-like self-assembly of gold nanoparticles for highly sensitive electrochemical detection of chromium(VI). , 2012, Analytica chimica acta.