Analysis and improvement of tipping calibration for ground-based microwave radiometers

The tipping-curve calibration method has been an important calibration technique for ground-based microwave radiometers that measure atmospheric emission at low optical depth. The method calibrates a radiometer system using data taken by the radiometer at two or more viewing angles in the atmosphere. In this method, the relationship between atmospheric opacity and viewing angle is used as a constraint for deriving the system calibration response. Because this method couples the system with radiative transfer theory and atmospheric conditions, evaluations of its performance have been difficult. In this paper, first a data-simulation approach is taken to isolate and analyze those influential factors in the calibration process and effective techniques are developed to reduce calibration uncertainties. Then, these techniques are applied to experimental data. The influential factors include radiometer antenna beam width, radiometer pointing error, mean radiating temperature error, and horizontal inhomogeneity in the atmosphere, as well as some other factors of minor importance. It is demonstrated that calibration uncertainties from these error sources can be large and unacceptable. Fortunately, it was found that by using the techniques reported, the calibration uncertainties can be largely reduced or avoided. With the suggested corrections, the tipping calibration method can provide absolute accuracy of about or better than 0.5 K.

[1]  Warner L. Ecklund,et al.  An Evaluation of Wind Profiler, RASS, and Microwave Radiometer Performance , 1993 .

[2]  Jan Askne,et al.  A Review of Ground-Based Remote Sensing of Temperature and Moisture by Passive Microwave Radiometers , 1986, IEEE Transactions on Geoscience and Remote Sensing.

[3]  J. B. Snider,et al.  Surface‐based radiometric observations of water vapor and cloud liquid in the temperate zone and in the tropics , 1998 .

[4]  J. R. Eyre,et al.  Assimilation of TOVS radiance information through one-dimensional variational analysis , 1993 .

[5]  S. Schwartz,et al.  The Atmospheric Radiation Measurement (ARM) Program: Programmatic Background and Design of the Cloud and Radiation Test Bed , 1994 .

[6]  David N. Whiteman,et al.  Observation of atmospheric fronts using Raman lidar moisture measurements , 1989 .

[7]  Steven Businger,et al.  GPS Meteorology: Direct Estimation of the Absolute Value of Precipitable Water , 1996 .

[8]  H. B. Howell,et al.  Radiometric calibration of IR Fourier transform spectrometers: solution to a problem with the High-Resolution Interferometer Sounder. , 1988, Applied optics.

[9]  IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, VOL. 34. NO. 4, JULY 1996 Universal Multifractal Scaling of Synthetic , 1996 .

[10]  Shepard A. Clough,et al.  Infrared spectral radiance measurements in the tropical , 1997 .

[11]  Richard K. Moore,et al.  Microwave Remote Sensing - Active and Passive - Volume I - Microwave Remote Sensing Fundamentals and Radiometry , 1981 .

[12]  S. H. Melfi,et al.  Raman lidar system for the measurement of water vapor and aerosols in the Earth's atmosphere. , 1992, Applied optics.

[13]  J. Goldsmith,et al.  Turn-key Raman lidar for profiling atmospheric water vapor, clouds, and aerosols. , 1997, Applied optics.

[14]  C. Dragone Characteristics of a broadband microwave corrugated feed: A comparison between theory and experiment , 1977, The Bell System Technical Journal.

[15]  J. C. Liljegren,et al.  Measurements of integrated water vapor and cloud liquid water from microwave radiometers at the DOE ARM Cloud and Radiation Testbed in the U.S. southern Great Plains , 1996, IGARSS '96. 1996 International Geoscience and Remote Sensing Symposium.

[16]  J. C. Liljegren,et al.  TWO-CHANNEL MICROWAVE RADIOMETER FOR OBSERVATIONS OF TOTAL COLUMN PRECIPITABLE WATER VAPOR AND CLOUD LIQUID WATER PATH , 1994 .

[17]  S. H. Melfi,et al.  Observations of water vapor by ground-based microwave radiometers and Raman lidar , 1994 .

[18]  Ed R. Westwater,et al.  The accuracy of water vapor and cloud liquid determination by dual‐frequency ground‐based microwave radiometry , 1978 .

[19]  A. Stogryn A Note on Brightness Temperature at Millimeter Wavelengths , 1975, IEEE Transactions on Geoscience Electronics.

[20]  James P. Hollinger,et al.  SSM/I instrument evaluation , 1990 .

[21]  J. B. Snider,et al.  Ground-based radiometric observations of atmospheric emission and attenuation at 20.6, 31.65, and 90.0 GHz: a comparison of measurements and theory , 1990 .

[22]  Ed R. Westwater,et al.  A Steerable Dual-Channel Microwave Radiometer for Measurement of Water Vapor and Liquid in the Troposphere , 1983 .

[23]  Yuri G. Trokhimovski,et al.  Sea‐air and boundary layer temperatures measured by a scanning 5‐mm‐wavelength radiometer: Recent results , 1998 .

[24]  S. H. Melfi,et al.  Observation of Lower-Atmospheric Moisture Structure and Its Evolution Using a Raman Lidar , 1985 .

[25]  Shepard A. Clough,et al.  Infrared spectral radiance measurements in the tropical Pacific atmosphere , 1997 .

[26]  Marco A. Janssen An Introduction to the Passive Microwave Remote Sensing of Atmospheres , 1993 .