A Buck Converter with Integrated Circuit Breaker

Power conversion and protection systems are often associated with two different devices; power electronic converters and circuit breakers. With power electronic converters enabling the integration of various dc sources, and circuit breakers providing system protection, both are essential in the reliability of dc networks. This paper introduces a non-isolated dc-dc power converter with integrated circuit breaker, able to simultaneously provide power conversion, and fault current limiting and interruption capabilities. The proposed system's topology, based on the series coupled inductor Z-Source Circuit Breaker (S-C-ZCB), inherits its automatic ability to limit fault currents and low-pass filter characteristic while reducing its footprint, operational and maintenance cost over traditional dc circuit breakers. Analysis of the proposed system, along with simulation results, are presented and compared during both steady-state operation and a fault on the output terminal.

[1]  Keith Corzine,et al.  Z-source Dc circuit breakers with coupled inductors , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[2]  Keith Corzine,et al.  A new z-source dc circuit breaker , 2010, ISIE 2010.

[3]  Keith A. Corzine,et al.  A New-Coupled-Inductor Circuit Breaker for DC Applications , 2017, IEEE Transactions on Power Electronics.

[4]  Chen Yuan,et al.  Protection Strategies for Medium-Voltage Direct-Current Microgrid at a Remote Area Mine Site , 2015, IEEE Transactions on Industry Applications.

[5]  Juan Manuel Mauricio,et al.  VSC-Based MVDC Railway Electrification System , 2014, IEEE Transactions on Power Delivery.

[6]  James L. Kirtley,et al.  Analysis and Design of DC System Protection Using Z-Source Circuit Breaker , 2016, IEEE Transactions on Power Electronics.

[7]  Johnson A. Asumadu,et al.  Γ-Z-source DC circuit breaker operation with variable coupling coefficient k , 2017, 2017 IEEE International Conference on Electro Information Technology (EIT).

[8]  P. Prempraneerach,et al.  Optimization of a z-source DC circuit breaker , 2013, 2013 IEEE Electric Ship Technologies Symposium (ESTS).

[9]  A. Hasanzadeh,et al.  Comparative study of intensive pulse load impact on active and passive rectification system in MVDC ship power generation unit , 2013, 2013 International Electric Machines & Drives Conference.

[10]  Daniel J. Ryan,et al.  The impact of source and fault impedance on post-fault response of Z-source circuit breakers , 2017, 2017 19th European Conference on Power Electronics and Applications (EPE'17 ECCE Europe).

[11]  Campbell Booth,et al.  MVDC for enhanced utility scale distribution power delivery and control , 2017, 2017 52nd International Universities Power Engineering Conference (UPEC).