Wire bonding quality monitoring via refining process of electrical signal from ultrasonic generator

In this paper, a technique for on-line quality detection of ultrasonic wire bonding is developed. The electrical signals from the ultrasonic generator supply, namely, voltage and current, are picked up by a measuring circuit and transformed into digital signals by a data acquisition system. A new feature extraction method is presented to characterize the transient property of the electrical signals and further evaluate the bond quality. The method includes three steps. First, the captured voltage and current are filtered by digital bandpass filter banks to obtain the corresponding subband signals such as fundamental signal, second harmonic, and third harmonic. Second, each subband envelope is obtained using the Hilbert transform for further feature extraction. Third, the subband envelopes are, respectively, separated into three phases, namely, envelope rising, stable, and damping phases, to extract the tiny waveform changes. The different waveform features are extracted from each phase of these subband envelopes. The principal components analysis (PCA) method is used for the feature selection in order to remove the relevant information and reduce the dimension of original feature variables. Using the selected features as inputs, an artificial neural network (ANN) is constructed to identify the complex bond fault pattern. By analyzing experimental data with the proposed feature extraction method and neural network, the results demonstrate the advantages of the proposed feature extraction method and the constructed artificial neural network in detecting and identifying bond quality.

[1]  Z. W. Zhong,et al.  Investigation of ultrasonic vibrations of wire-bonding capillaries , 2006, Microelectron. J..

[2]  Shih-Fu Ling,et al.  Real-Time Quality Evaluation of Wire Bonding Using Input Impedance , 2006, IEEE Transactions on Electronics Packaging Manufacturing.

[3]  Helen Lai Wa Chan,et al.  Smart ultrasonic transducer for wire-bonding applications , 2002 .

[4]  M. Gaitan,et al.  Wire-bonding process monitoring using thermopile temperature sensor , 2005, IEEE Transactions on Advanced Packaging.

[5]  Kei Chun Cheng,et al.  Characterization of piezoelectric ring used for wire bonding transducer application , 2001, Proceedings 2001 IEEE Hong Kong Electron Devices Meeting (Cat. No.01TH8553).

[6]  N.M. Bilgutay,et al.  Analysis of impedance loading in ultrasonic transducer systems , 1988, IEEE 1988 Ultrasonics Symposium Proceedings..

[7]  Saeed V. Vaseghi,et al.  Advanced Digital Signal Processing and Noise Reduction , 2006 .

[8]  Shih-Fu Ling,et al.  Monitoring wire bonding via time-frequency analysis of horn vibration , 2003 .

[9]  G. Harman,et al.  Wire bonding in microelectronics , 2010 .

[10]  Siu Wing Or,et al.  Ultrasonic wire-bond quality monitoring using piezoelectric sensor , 1998 .

[11]  R. Pufall,et al.  Automatic process control of wire bonding , 1993, Proceedings of IEEE 43rd Electronic Components and Technology Conference (ECTC '93).

[12]  H. Reichl,et al.  Predicting the Shear Strength of a Wire Bond Using Laser Vibration Measurements , 2006, 2006 1st Electronic Systemintegration Technology Conference.