Clinical applications of pulse transit time in paediatric critical care

A simple and non-invasive technique, termed pulse transit time (PTT), has shown its potential in long-term investigations such as respiratory sleep studies and cardiovascular studies. Based on these findings, the PTT technique shows relevance for continuous haemodynamic monitoring in critical care. The objective of this review is to understand the potential, applications and limitations of PTT in this clinical setting. Present non-invasive haemodynamic monitoring methods such as automated oscillometric blood pressure (BP) and auscultatory techniques have their known limitations. They tend to underestimate systolic BP while overestimating diastolic BP. Due to the periodic increase in cuff pressure cycles during data acquisition, these techniques may cause much discomfort in elderly geriatric patients, or lessen the cooperation of younger paediatric patients. Thus, there can be adverse effects on therapeutic decisions and possibly clinical outcomes. Documented evidences have indicated that changes observed in PTT are inversely correlated to the corresponding BP changes. In critical care, a simple and accommodating technique like PTT may be useful in providing better comfort for patients during extended monitoring. Being a semi-quantitative measure, blanket recommendations for its utility can then become possible. The basic instrumentations needed are often part of standard critical care monitoring system. Furthermore, PTT also has the potential to monitor the often tachypnoeic respiratory dependent BP changes seen in small infants during critical care.

[1]  J. Naschitz,et al.  Pulse Transit Time by R-Wave-Gated Infrared Photoplethysmography: Review of the Literature and Personal Experience , 2004, Journal of Clinical Monitoring and Computing.

[2]  D. M. Cooper,et al.  Motion artefact reduction of the photoplethysmographic signal in pulse transit time measurement , 2004, Australasian Physics & Engineering Sciences in Medicine.

[3]  John K-J Li,et al.  A Noninvasive Parametric Evaluation of Stress Effects on Global Cardiovascular Function , 2007, Cardiovascular engineering.

[4]  Hironori Ishihara,et al.  A New Non-Invasive Continuous Cardiac Output Trend Solely Utilizing Routine Cardiovascular Monitors , 2004, Journal of Clinical Monitoring and Computing.

[5]  T. Pickering,et al.  What will replace the mercury sphygmomanometer? , 2003, Blood pressure monitoring.

[6]  C. Lim,et al.  Study of pulse transit time oscillations during obstructive sleep apnoea by using a distributed model. , 2007, Journal of biomechanics.

[7]  C. Ahlstrom,et al.  Noninvasive investigation of blood pressure changes using the pulse wave transit time: a novel approach in the monitoring of hemodialysis patients , 2005, Journal of Artificial Organs.

[8]  P. Chowienczyk,et al.  Contour analysis of the photoplethysmographic pulse measured at the finger , 2006, Journal of hypertension.

[9]  J. Blacher,et al.  Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients. , 1999, Hypertension.

[10]  Andrew P Bradley,et al.  Use of pulse transit time to distinguish respiratory events from tidal breathing in sleeping children. , 2005, Chest.

[11]  J. Sleigh,et al.  Nociceptive and anaesthetic-induced changes in pulse transit time during general anaesthesia. , 2003, British journal of anaesthesia.

[12]  P. Marik,et al.  The obese patient in the ICU. , 1998, Chest.

[13]  Andra L. Blomkalns,et al.  The Obese Patient , 2011 .

[14]  J. Stradling,et al.  Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea. , 1995, The European respiratory journal.

[15]  Robert Rauh,et al.  Quantification of inspiratory‐induced vasoconstrictive episodes: a comparison of laser Doppler fluxmetry and photoplethysmography , 2003, Clinical physiology and functional imaging.

[16]  F. Paccaud,et al.  Difference in Blood Pressure Readings with Mercury and Automated Devices: Impact on Hypertension Prevalence Estimates in Dar es Salaam, Tanzania , 2006, European Journal of Epidemiology.

[17]  Jong Yong Abdiel Foo Development of a temperature-controlled miniature enclosure for monitoring poor perfusion photoplethysmographic signals. , 2007, Physiological measurement.

[18]  Jamil Mayet,et al.  Determination of optimal atrioventricular delay for cardiac resynchronization therapy using acute non-invasive blood pressure. , 2006, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[19]  J. Trinder,et al.  Pathophysiological interactions of ventilation, arousals, and blood pressure oscillations during cheyne-stokes respiration in patients with heart failure. , 2000, American journal of respiratory and critical care medicine.

[20]  J. Foo,et al.  Predictive regression equations and clinical uses of peripheral pulse timing characteristics in children , 2005, Physiological measurement.

[21]  K. Bailey,et al.  The trained observer better predicts daytime ABPM diastolic blood pressure in hypertensive patients than does an automated (Omron) device , 2006, Blood pressure monitoring.

[22]  Daniel W. Jones,et al.  Measuring blood pressure accurately: new and persistent challenges. , 2003, JAMA.

[23]  A P Avolio,et al.  Effects of aging on arterial distensibility in populations with high and low prevalence of hypertension: comparison between urban and rural communities in China. , 1985, Circulation.

[24]  Kazuomi Kario,et al.  The value of home blood pressure monitoring , 2006, Current hypertension reports.

[25]  T. Itoh,et al.  Mechanisms underlying the reduced endothelium‐dependent relaxation in human omental resistance artery in pre‐eclampsia , 2000, The Journal of physiology.

[26]  A Murray,et al.  Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes , 2002, Journal of Human Hypertension.

[27]  Patrick Levy,et al.  Pulse transit time improves detection of sleep respiratory events and microarousals in children. , 2005, Chest.

[28]  Y. Cheung,et al.  Arterial distensibility in children and teenagers: normal evolution and the effect of childhood vasculitis , 2002, Archives of disease in childhood.

[29]  G. Parati,et al.  Blood pressure measurement in research and in clinical practice: recent evidence , 2004, Current opinion in nephrology and hypertension.

[30]  C. Lim,et al.  Evaluation of blood pressure changes using vascular transit time , 2006, Physiological measurement.

[31]  Alan Murray,et al.  Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristics , 2005, Physiological measurement.

[32]  Panayiotis A. Kyriacou,et al.  Esophageal pulse oximetry utilizing reflectance photoplethysmography , 2002, IEEE Transactions on Biomedical Engineering.

[33]  P A Kyriacou,et al.  Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients. , 2002, Physiological measurement.

[34]  G. Drummond,et al.  Assessment of pulse transit time to indicate cardiovascular changes during obstetric spinal anaesthesia. , 2006, British journal of anaesthesia.

[35]  J Y A Foo,et al.  Age-related factors that confound peripheral pulse timing characteristics in Caucasian children , 2005, Journal of Human Hypertension.

[36]  David Gozal,et al.  Potential usefulness of noninvasive autonomic monitoring in recognition of arousals in normal healthy children. , 2007, Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine.

[37]  Peter R. Smith,et al.  A new method for pulse oximetry possessing inherent insensitivity to artifact , 2001, IEEE Transactions on Biomedical Engineering.

[38]  R. Payne,et al.  Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure. , 2006, Journal of applied physiology.

[39]  E. Katz,et al.  Pulse Transit Time as a Measure of Arousal and Respiratory Effort in Children with Sleep-Disordered Breathing , 2003, Pediatric Research.

[40]  Jonathan Himmelfarb,et al.  Current Opinion in Nephrology and Hypertension , 2010 .

[41]  N. Stergiopulos,et al.  Total arterial inertance as the fourth element of the windkessel model. , 1999, American journal of physiology. Heart and circulatory physiology.

[42]  J. Pépin,et al.  Pulse transit time: an appraisal of potential clinical applications , 1999, Thorax.

[43]  R. Burattini,et al.  Complex and frequency-dependent compliance of viscoelastic windkessel resolves contradictions in elastic windkessels. , 1998, Medical engineering & physics.

[44]  T. Thien,et al.  Is the accuracy of blood pressure measuring devices underestimated at increasing blood pressure levels? , 2005, Blood pressure monitoring.

[45]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[46]  David W Roberson,et al.  Pulse transit time as a screening test for pediatric sleep-related breathing disorders. , 2007, Archives of otolaryngology--head & neck surgery.

[47]  Jong Yong Abdiel Foo,et al.  Changes induced in the lower- and upper-limb pulse transit-time ratio during inspiratory resistive breathing , 2007, Biomedizinische Technik. Biomedical engineering.

[48]  I. Saito,et al.  Which measurement of home blood pressure should be used for clinical evaluation when multiple measurements are made? , 2007, Journal of hypertension.

[49]  Stephen James Wilson,et al.  A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states , 2006, Medical and Biological Engineering and Computing.