Evaluation of IEC 61850-9-2 samples loss on total vector error of an estimated phasor

This paper evaluates the performance of proposed phasor estimator at different operating conditions within IEC 61850. The estimator relies on the Unsented Kalman Filter which is employed for computing the Phasor based on IEC 61850-9-2 Sampled Measured Values casted by the substation merging units. The criterion for evaluating the estimated Phasor is the Total Vector Error as define in IEEE C37.118 standard. The Total Vector Error is analyzed for the effects of the IEC 61850-9-2 samples loss, operating conditions at different Nodes Number and IEC 61850-9-2 frame size.

[1]  Adly A. Girgis,et al.  Identification and tracking of harmonic sources in a power system using a Kalman filter , 1996 .

[2]  Edith Clarke,et al.  Determination of Instantaneous Currents and Voltages by Means of Alpha, Beta, and Zero Components , 1951, Transactions of the American Institute of Electrical Engineers.

[3]  Vladimir Terzija,et al.  Unscented Kalman Filter for frequency and amplitude estimation , 2011, 2011 IEEE Trondheim PowerTech.

[4]  H. Lesani,et al.  New technique for frequency and amplitude estimation of power system signals , 2005 .

[5]  A.G. Phadke,et al.  Synchronized phasor measurements in power systems , 1993, IEEE Computer Applications in Power.

[6]  A. Girgis,et al.  A digital recursive measurement scheme for online tracking of power system harmonics , 1991 .

[7]  Ganapati Panda,et al.  Frequency estimation of distorted power system signals using extended complex Kalman filter , 1999 .

[8]  Ganapati Panda,et al.  An extended complex Kalman filter for frequency measurement of distorted signals , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[9]  G. Brunello,et al.  An overview of the IEEE Standard C37.118.2 — Synchrophasor Data Transfer for Power Systems , 2014 .

[10]  J. Thorp,et al.  A New Measurement Technique for Tracking Voltage Phasors, Local System Frequency, and Rate of Change of Frequency , 1983, IEEE Transactions on Power Apparatus and Systems.

[11]  C. Steinmetz Theory and Calculation of Alternating Current Phenomena , 2008 .

[12]  R. Zivanovic Analysis of recorded transients on 765kV lines with shunt reactors , 2005, 2005 IEEE Russia Power Tech.

[13]  V. M. Moreno Saiz,et al.  Application of Kalman filtering for continuous real-time tracking of power system harmonics , 1997 .

[14]  Irene Yu-Hua Gu,et al.  Voltage dip detection and power system transients , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).

[15]  Anton Cervin,et al.  TrueTime 1.1 -- Reference Manual , 2003 .

[16]  Sergio M. Savaresi,et al.  On the parametrization and design of an extended Kalman filter frequency tracker , 2000, IEEE Trans. Autom. Control..

[17]  Michele Passerini Design of an ECMA368 simulator for evaluating network performance for electrical substation applications based on IEC61850 , 2008 .

[18]  Jeffrey K. Uhlmann,et al.  Unscented filtering and nonlinear estimation , 2004, Proceedings of the IEEE.

[19]  Pradipta Kishore Dash,et al.  Harmonics estimation in stressed electric power networks , 2001, 4th IEEE International Conference on Power Electronics and Drive Systems. IEEE PEDS 2001 - Indonesia. Proceedings (Cat. No.01TH8594).

[20]  A. Abdolkhalig,et al.  Towards dynamic on-line state estimator based on IEC61850–9–2 Process Bus , 2012, 2012 16th IEEE Mediterranean Electrotechnical Conference.