Contactless respiration monitoring of infants

Five alternative contactless methods for monitoring respiration in infants during the first year of life are evaluated. The methods are: (i) an air-filled mattress system, (ii) an under-mattress pressure sensor, (iii) a magnetometer and magnet, (iv) a capacitance-change detector and (v) a radar reflection system. A battery-powered 2-channel radar system is described in detail and some results are given of information obtained from overnight recordings in infants.SommaireOn a évalué cing méthodes différentes de contrôle sans contact de la respiration infantile pendant la première année d'existence. Ces méthodes sont les suivantes: (i) système de matelas rempli d'air; (ii) détectuer de pression sous matelas; (iii) magnétomètre à aimant; (iv) détecteur de changement de capacité et (v) système de réflection radar. L'article décrit en détail un système radar à deux canaux à pile et présente quelques résultats d'informations obtenues à partir d'enregistrements effectués chez des enfants au cours de la nuit.ZusammenfassungEs wurden fünf alternative kontaktlose Verfahren zur Atemüberwachung von Säuglingen während des ersten Lebensjahres beurteilt. Es handelte sich um folgende Verfahren: (i) das luftgefüllte Matratzensystem, (ii) Druckfühler unter der Matratze, (iii) Magnetometer und Magnet, (iv) Kapazitanzänderungssucher und (v) ein Radar-Reflektionssystem. Ein batteriebetriebenes Radarsystem mit zwei Kanälen wird genauer beschrieben, und es werden einige Ergebnisse in Form von Daten aus während der Nacht an Säuglingen vorgenommenen Aufzeichnungen angegeben.

[1]  G. Polgar Comparison of methods for recording respiration in newborn infants. , 1965, Pediatrics.

[2]  Response of premature infants with periodic breathing to ventilatory stimuli. , 1966, Journal of applied physiology.

[3]  L H Hamilton,et al.  Factors affecting transthoracic impedance signals used to measure breathing. , 1967, Journal of applied physiology.

[4]  J E Lewin,et al.  An apnoea-alarm mattress. , 1969, Lancet.

[5]  W. Daily,et al.  Apnea in premature infants: monitoring, incidence, heart rate changes, and an effect of environmental temperature. , 1969, Pediatrics.

[6]  J. E. Lewin,et al.  AN APNŒA-ALARM MATTRESS , 1969 .

[7]  L. Victorin,et al.  Transthoracic Impedance: III. Methodological Studies in Newborn Infants , 1970 .

[8]  C G Caro,et al.  Contactless apnoea detector based on radar. , 1971, Lancet.

[9]  S. Kira,et al.  Transthoracic electrical impedance variations associated with respiration. , 1971, Journal of applied physiology.

[10]  A. Steinschneider,et al.  Prolonged apnea and the sudden infant death syndrome: clinical and laboratory observations. , 1972, Pediatrics.

[11]  H. Rigatto,et al.  Periodic breathing and apnea in preterm infants. I. Evidence for hypoventilation possibly due to central respiratory depression. , 1972, Pediatrics.

[12]  S. M. Michaelson,et al.  Human exposure to nonionizing radiant energy—Potential hazards and safety standards , 1972 .

[13]  H. Prechtl,et al.  Behavioural State Cycles in Abnormal Infants , 1973, Developmental medicine and child neurology.

[14]  K. Barrington,et al.  Periodic Breathing and Apnea in Preterm Infants , 1990, Pediatric Research.

[15]  B. H. Brown,et al.  Simple impedance pneumograph and volume integrator , 2006, Medical and biological engineering.

[16]  J. Gundersen,et al.  Monitoring of breathing with a segmental air-filled mattress , 1971, Medical and biological engineering.

[17]  John Dimeff,et al.  A wireless respiration failure detection system , 1974, Medical and biological engineering.