Development and Preliminary Evaluation of a Smartphone App for Measuring Eye Alignment

Purpose We evaluate a smartphone application (app) performing an automated photographic Hirschberg test for measurement of eye deviations. Methods Three evaluation studies were conducted to measure eye deviations in the horizontal direction. First, gaze angles were measured with respect to the ground truth in nonstrabismic subjects (n = 25) as they fixated monocularly on targets of known eccentricity covering an angular range of approximately ±13°. Second, phoria measurements with the app at near fixation (distance = 40 cm) were compared with the modified Thorington (MT) test in normally-sighted subjects (n = 14). Third, eye deviations using the app were compared to a cover test with prism neutralization (CTPN; n = 66) and Synoptophore (n = 34) in strabismic subjects. Regression analyses were used to compare the app and clinical measurements of the magnitude and direction of eye deviations (prism diopters, Δ). Results The gaze angles measured by the app closely followed the ground truth (slope = 1.007, R2 = 0.97, P < 0.001), with a root mean squared error (RMSE) of 2.4Δ. Phoria measurements with the app were consistent with MT (slope = 0.94, R2 = 0.97, P < 0.001, RMSE = 1.7Δ). Overall, the strabismus measurements with the app were higher than with Synoptophore (slope = 1.15, R2 = 0.91, P < 0.001), but consistent with CTPN (slope = 0.95, R2 = 0.95, P < 0.001). After correction of CTPN values for near fixation, the consistency of the app measurements with CTPN was improved further (slope = 1.01). Conclusions The app measurements of manifest and latent eye deviations were consistent with the comparator clinical methods. Translational Relevance A smartphone app for measurement of eye alignment can be a convenient clinical tool and has potential to be beneficial in telemedicine.

[1]  P. Buisseret,et al.  The sensitive period for strabismic amblyopia in humans. , 1993, Ophthalmology.

[2]  J. Naor,et al.  Early screening for amblyogenic risk factors lowers the prevalence and severity of amblyopia. , 2000, Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus.

[3]  Veena Bhardwaj,et al.  Axial length, anterior chamber depth-a study in different age groups and refractive errors. , 2013, Journal of clinical and diagnostic research : JCDR.

[4]  Z. Georgievski Synoptophore versus prism and cover test measurements in strabismus.: A question of instrument convergence? , 1995, Strabismus.

[5]  J. Demer,et al.  Quality of life in adults with strabismus. , 2015, American journal of ophthalmology.

[6]  D. Loran,et al.  DESIGNING CONTACT LENSES FOR ORIENTAL EYES , 1991 .

[7]  S. Loudon,et al.  Rapid, high-accuracy detection of strabismus and amblyopia using the pediatric vision scanner. , 2011, Investigative ophthalmology & visual science.

[8]  F. Rowe The profile of strabismus in stroke survivors , 2010, Eye.

[9]  M. Repka,et al.  Risk of musculoskeletal injuries, fractures, and falls in medicare beneficiaries with disorders of binocular vision. , 2015, JAMA ophthalmology.

[10]  J. Barry,et al.  Limbus versus pupil center for ocular alignment measurement with corneal reflexes. , 1997, Investigative ophthalmology & visual science.

[11]  A. Kemper,et al.  Preschool Vision Screening in Pediatric Practices , 2006, Clinical pediatrics.

[12]  D. Goss,et al.  Reliability of and comparisons among methods of measuring dissociated phoria. , 1996, Optometry and vision science : official publication of the American Academy of Optometry.

[13]  Douglas G. Altman,et al.  Measurement in Medicine: The Analysis of Method Comparison Studies , 1983 .

[14]  Shrikant R Bharadwaj,et al.  Utility of Theoretical Hirschberg Ratio for Gaze Position Calibration , 2014, Optometry and vision science : official publication of the American Academy of Optometry.

[15]  J M Sparrow,et al.  Amblyopia treatment outcomes after screening before or at age 3 years: follow up from randomised trial , 2002, BMJ : British Medical Journal.

[16]  S. Brodie Photographic calibration of the Hirschberg test. , 1987, Investigative ophthalmology & visual science.

[17]  Alan W. Freeman,et al.  Components of visual acuity loss in strabismus , 1996, Vision Research.

[18]  R. Kono,et al.  Biometric confirmation of the Hirschberg ratio in strabismic children. , 1998, Investigative ophthalmology & visual science.

[19]  Moshe Eizenman,et al.  An Automated Hirschberg Test for Infants , 2011, IEEE Transactions on Biomedical Engineering.

[20]  S. Hasebe,et al.  The reliability of a video-enhanced Hirschberg test under clinical conditions. , 1995, Investigative ophthalmology & visual science.

[21]  Naoyuki Maeda,et al.  Anterior chamber depth in normal subjects by rotating scheimpflug imaging. , 2011, Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society.

[22]  P. Mitchell,et al.  Factors associated with childhood strabismus: findings from a population-based study. , 2006, Ophthalmology.

[23]  Moshe Eizenman,et al.  Fixation-free assessment of the Hirschberg ratio. , 2010, Investigative ophthalmology & visual science.

[24]  David G Hunter,et al.  The Pediatric Vision Screener III: detection of strabismus in children. , 2006, Archives of ophthalmology.

[25]  K. Mashige,et al.  A review of corneal diameter, curvature and thickness values and influencing factors* , 2013 .

[26]  S. Azen,et al.  Fixation preference and visual acuity testing in a population-based cohort of preschool children with amblyopia risk factors. , 2009, Ophthalmology.

[27]  Ernst Martin,et al.  Neurodevelopment of the visual system in typically developing children. , 2011, Progress in brain research.

[28]  Anselmo Cardoso de Paiva,et al.  Computational methodology for automatic detection of strabismus in digital images through Hirschberg test , 2012, Comput. Biol. Medicine.

[29]  R. T. Kame,et al.  Clinical Comparison of Corneal Diameter and Curvature in Asian Eyes with Those of Caucasian Eyes , 1992, Optometry and vision science : official publication of the American Academy of Optometry.

[30]  D L Guyton,et al.  Ophthalmic prisms. Deviant behavior at near. , 1985, Ophthalmology.

[31]  Pablo Artal,et al.  Optics of the eye and its impact in vision: a tutorial , 2014 .

[32]  Wei Sun,et al.  Corneal Curvature Radius and Associated Factors in Chinese Children: The Shandong Children Eye Study , 2015, PloS one.