Phase-sensitive optical low-coherence reflectometry for the detection of analyte concentrations.

Optical techniques may potentially be used for noninvasive glucose sensing. We investigated the application of phase-sensitive optical low-coherence reflectometry (PS-OLCR) to the measurement of analyte concentrations. The dependence of the PS-OLCR signal on the concentration of various analytes, including aqueous solutions of glucose, calcium chloride, magnesium chloride, sodium chloride, potassium chloride, potassium bicarbonate, urea, bovine serum albumin, and bovine globulin, were determined in clear and turbid media. Obtained results demonstrated (1) a high degree of sensitivity and accuracy of the phase measurements of analyte concentrations with PS-OLCR; (2) a concentration-dependent change in the phase-shift for glucose that is significantly greater than that of other analytes sampled over the same physiological range; and (3) a high submillimolar sensitivity of PS-OLCR for the measurement of glucose concentration. Further exploration of the application of PS-OLCR to the noninvasive, sensitive, and specific monitoring of glucose concentration seems warranted.

[1]  A. Fercher,et al.  Optical coherence tomography - principles and applications , 2003 .

[2]  P. Monnier,et al.  Three‐dimensional optical phantom and its application in photodynamic therapy , 1997, Lasers in surgery and medicine.

[3]  R. C. Weast CRC Handbook of Chemistry and Physics , 1973 .

[4]  Henry Grady Rylander,et al.  Interferometric fiber-based optical biosensor to measure ultra-small changes in refractive index , 2002, SPIE BiOS.

[5]  Measurement of particle size distribution in multilayered skin phantoms using polarized light spectroscopy. , 2002, Physical review. E, Statistical, nonlinear, and soft matter physics.

[6]  C K Hitzenberger,et al.  Differential phase contrast in optical coherence tomography. , 1999, Optics letters.

[7]  T. Milner,et al.  Optical low-coherence reflectometer for differential phase measurement. , 2000, Optics letters.

[8]  J. Fujimoto,et al.  High-speed phase- and group-delay scanning with a grating-based phase control delay line. , 1997, Optics letters.

[9]  R. Esenaliev,et al.  Noninvasive monitoring of glucose concentration with optical coherence tomography , 2001 .

[10]  R. Scully,et al.  Case records of the Massachusetts General Hospital. , 1990 .

[11]  R. Esenaliev,et al.  Noninvasive blood glucose monitoring with optical coherence tomography: a pilot study in human subjects. , 2002, Diabetes care.

[12]  A. Kratz,et al.  Case records of the Massachusetts General Hospital. Weekly clinicopathological exercises. Normal reference laboratory values. , 1998, The New England journal of medicine.

[13]  Massoud Motamedi,et al.  Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study. , 2003, Physics in medicine and biology.

[14]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[15]  R. Cully,et al.  Weekly clinicopathological exercises. , 1990, The New England journal of medicine.

[16]  Z. Kam,et al.  Absorption and Scattering of Light by Small Particles , 1998 .

[17]  Joseph M. Schmitt,et al.  Optical coherence tomography (OCT): a review , 1999 .

[18]  Taner Akkin,et al.  Imaging tissue response to electrical and photothermal stimulation with nanometer sensitivity , 2003, Lasers in surgery and medicine.

[19]  M S Jacobson,et al.  Normal reference laboratory values? , 1978, The New England journal of medicine.

[20]  A. Fercher,et al.  Quantitative differential phase measurement and imaging in transparent and turbid media by optical coherence tomography. , 2001, Optics letters.

[21]  M S Feld,et al.  Path-length-resolved dynamic light scattering: modeling the transition from single to diffusive scattering. , 2001, Applied optics.