On the validity of 3D polymer gel dosimetry: II. Physico-chemical effects

This study quantifies some major physico-chemical factors that influence the validity of MRI (PAGAT) polymer gel dosimetry: temperature history (pre-, during and post-irradiation), oxygen exposure (post-irradiation) and volumetric effects (experiment with phantom in which a small test tube is inserted). Present results confirm the effects of thermal history prior to irradiation. By exposing a polymer gel sample to a linear temperature gradient of ∼2.8 °C cm⁻¹ and following the dose deviation as a function of post-irradiation time new insights into temporal variations were added. A clear influence of the temperature treatment on the measured dose distribution is seen during the first hours post-irradiation (resulting in dose deviations up to 12%). This effect diminishes to 5% after 54 h post-irradiation. Imposing a temperature offset (maximum 6 °C for 3 h) during and following irradiation on a series of calibration phantoms results in only a small dose deviation of maximum 4%. Surprisingly, oxygen diffusing in a gel dosimeter up to 48 h post-irradiation was shown to have no effect. Volumetric effects were studied by comparing the dose distribution in a homogeneous phantom compared to the dose distribution in a phantom in which a small test tube was inserted. This study showed that the dose measured inside the test tube was closer to the ion chamber measurement in comparison to the reference phantom without test tube by almost 7%. It is demonstrated that physico-chemical effects are not the major causes for the dose discrepancies encountered in the reproducibility study discussed in the concurrent paper (Vandecasteele and De Deene 2013a Phys. Med. Biol. 58 19-42). However, it is concluded that these physico-chemical effects are important factors that should be addressed to further improve the dosimetric accuracy of 3D MRI polymer gel dosimetry.

[1]  Yves De Deene,et al.  On the validity of 3D polymer gel dosimetry: III. MRI-related error sources , 2013, Physics in medicine and biology.

[2]  J. Gore,et al.  Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters. , 1997, International journal of radiation oncology, biology, physics.

[3]  Temperature increases associated with polymerization of irradiated PAG dosimeters. , 2002, Physics in medicine and biology.

[4]  S. Webb,et al.  The reproducibility of polyacrylamide gel dosimetry applied to stereotactic conformal radiotherapy. , 2000, Physics in medicine and biology.

[5]  M. Lepage,et al.  Severe dose inaccuracies caused by an oxygen-antioxidant imbalance in normoxic polymer gel dosimeters , 2011, Physics in medicine and biology.

[6]  Cheng-Shie Wuu,et al.  Sensitivity calibration procedures in optical-CT scanning of BANG 3 polymer gel dosimeters. , 2010, Medical physics.

[7]  Yves De Deene,et al.  On the validity of 3D polymer gel dosimetry: I. Reproducibility study , 2013, Physics in medicine and biology.

[8]  C De Wagter,et al.  The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels , 2006, Physics in medicine and biology.

[9]  M. Lepage,et al.  Investigating potential physicochemical errors in polymer gel dosimeters , 2011, Physics in medicine and biology.

[10]  Sergey Vyazovkin,et al.  Temperature dependence of sol-gel conversion kinetics in gelatin-water system. , 2009, Macromolecular bioscience.

[11]  C Baldock,et al.  Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters. , 2002, Physics in medicine and biology.

[12]  J. Douglas,et al.  A general formulation of alternating direction methods , 1964 .

[13]  C. De Wagter,et al.  On the relation between the spatial dose integrity and the temporal instability of polymer gel dosimeters. , 2004, Physics in medicine and biology.

[14]  Effects of phantom volume and shape on the accuracy of MRI BANG gel dosimetry using BANG3. , 2008, The British journal of radiology.

[15]  J C Gore,et al.  Radiation therapy dosimetry using magnetic resonance imaging of polymer gels. , 1996, Medical physics.

[16]  Rik Van de Walle,et al.  Mathematical analysis and experimental investigation of noise in quantitative magnetic resonance imaging applied in polymer gel dosimetry , 1998, Signal Process..

[17]  Alice C. Harris,et al.  What is Reproducibility , 2006 .

[18]  Effect of container size on the accuracy of polymer gel dosimetry , 2006 .

[19]  R. Buxton The physics of functional magnetic resonance imaging (fMRI) , 2013, Reports on progress in physics. Physical Society.

[20]  C. Baldock,et al.  Experimental study of attenuation properties of normoxic polymer gel dosimeters. , 2004, Physics in medicine and biology.

[21]  J. Gore,et al.  NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: a new approach to 3D dosimetry by MRI. , 1993, Magnetic resonance imaging.

[22]  J C Gore,et al.  The effects of cross-link density and chemical exchange on magnetization transfer in polyacrylamide gels. , 1996, Journal of magnetic resonance. Series B.

[23]  C Baldock,et al.  A basic study of some normoxic polymer gel dosimeters. , 2002, Physics in medicine and biology.

[24]  J C Gore,et al.  Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter , 1994, Physics in medicine and biology.

[25]  J. Gore,et al.  Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging. , 1984, Physics in medicine and biology.

[26]  M O Leach,et al.  Dynamics of polymerization in polyacrylamide gel (PAG) dosimeters: (II) modeling oxygen diffusion. , 1999, Physics in medicine and biology.

[27]  C Baldock,et al.  Investigation of the PAGAT polymer gel dosimeter using magnetic resonance imaging , 2005, Physics in medicine and biology.

[28]  Y. De Deene,et al.  The influence of cooling rate on the accuracy of normoxic polymer gel dosimeters , 2007, Physics in medicine and biology.

[29]  L E Olsson,et al.  MR imaging of absorbed dose distributions for radiotherapy using ferrous sulphate gels. , 1990, Physics in medicine and biology.