Remote monitoring of implantable-cardioverter defibrillators: results from the Reliability of IEGM Online Interpretation (RIONI) study.

AIMS Intracardiac electrograms (IEGMs) recorded by implantable cardioverter-defibrillators (ICDs) are essential for arrhythmia diagnosis and ICD therapy assessment. Short IEGM snapshots showing 3-10 s before arrhythmia detection were added to the Biotronik Home Monitoring system in 2005 as the first-generation IEGM Online. The RIONI study tested the primary hypothesis that experts' ratings regarding the appropriateness of ICD therapy based on IEGM Online and on standard 30 s IEGM differ in <10% of arrhythmia events. METHODS AND RESULTS A total of 619 ICD patients were enrolled and followed for 1 year. According to a predefined procedure, 210 events recorded by the ICDs were selected for evaluation. Three expert board members rated the appropriateness of ICD therapy and classified the underlying arrhythmia using coded IEGM Online and standard IEGM to avoid bias. The average duration of IEGM Online was 4.4±1.5 s. According to standard IEGM, the underlying arrhythmia was ventricular in 135 episodes (64.3%), supraventricular in 53 episodes (25.2%), oversensing in 17 episodes (8.1%), and uncertain in 5 episodes (2.4%). The expert board's rating diverged between determinable IEGM Online tracings and standard IEGM in 4.6% of episodes regarding the appropriateness of ICD therapy (95% CI up to 8.0%) and in 6.6% of episodes regarding arrhythmia classification (95% CI up to 10.5%). CONCLUSION By enabling accurate evaluation of the appropriateness of ICD therapy and the underlying arrhythmia, the first-generation IEGM Online provided a clinically effective basis for timely interventions and for optimized patient management schemes, which was comparable with current IEGM recordings.

[1]  R. Schweikert,et al.  Efficacy and Safety of Automatic Remote Monitoring for Implantable Cardioverter-Defibrillator Follow-Up: The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) Trial , 2010, Circulation.

[2]  Gillian D Sanders,et al.  Remote Monitoring of Implantable Cardioverter Defibrillators versus Quarterly Device Interrogations in Clinic: Results from a Randomized Pilot Clinical Trial , 2010, Journal of cardiovascular electrophysiology.

[3]  Renato Pietro Ricci,et al.  Long-term patient acceptance of and satisfaction with implanted device remote monitoring. , 2010, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[4]  B. Wilkoff,et al.  Clinical benefits of remote versus transtelephonic monitoring of implanted pacemakers. , 2009, Journal of the American College of Cardiology.

[5]  B. Lindsay,et al.  Review of the ICD Registry's third year, expansion to include lead data and pediatric ICD procedures, and role for measuring performance. , 2009, Heart rhythm.

[6]  G. Lip,et al.  Multicenter randomized study of anticoagulation guided by remote rhythm monitoring in patients with implantable cardioverter-defibrillator and CRT-D devices: Rationale, design, and clinical characteristics of the initially enrolled cohort The IMPACT study. , 2009, American heart journal.

[7]  G. Parati,et al.  Design of the evolution of management strategies of heart failure patients with implantable defibrillators (EVOLVO) study to assess the ability of remote monitoring to treat and triage patients more effectively , 2009, Trials.

[8]  Haran Burri,et al.  Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators , 2009, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[9]  N. Varma Remote Monitoring for Advisories: Automatic Early Detection of Silent Lead Failure , 2009, Pacing and clinical electrophysiology : PACE.

[10]  L. Jordaens,et al.  Analysis of 57,148 Transmissions by Remote Monitoring of Implantable Cardioverter Defibrillators , 2009, Pacing and clinical electrophysiology : PACE.

[11]  N. Varma,et al.  Prevalence of Cancelled Shock Therapy and Relationship to Shock Delivery in Recipients of Implantable Cardioverter‐Defibrillators Assessed by Remote Monitoring , 2009, Pacing and clinical electrophysiology : PACE.

[12]  A. Schirdewan,et al.  Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure. , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[13]  J. Marine Remote monitoring for prevention of inappropriate implantable cardioverter defibrillator shocks: is there no place like home? , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[14]  M. Wright,et al.  Remote implantable cardioverter defibrillator monitoring in a Brugada syndrome population. , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[15]  Renato Pietro Ricci,et al.  Remote control of implanted devices through Home Monitoring technology improves detection and clinical management of atrial fibrillation. , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[16]  A. Boyle,et al.  Trial design of the clinical evaluation of remote notification to reduce time to clinical decision: the Clinical evaluation Of remote NotificatioN to rEduCe Time to clinical decision (CONNECT) study. , 2008, American heart journal.

[17]  G. Hindricks,et al.  Influence of Home Monitoring on the clinical status of heart failure patients: Design and rationale of the IN‐TIME study , 2008, European journal of heart failure.

[18]  P. Vardas,et al.  Tools and strategies for the reduction of inappropriate implantable cardioverter defibrillator shocks. , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[19]  A. Brecher,et al.  Performance of an Autonomous Telemonitoring System in Children and Young Adults with Congenital Heart Diseases , 2008, Pacing and clinical electrophysiology : PACE.

[20]  U. Meyerfeldt,et al.  Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems , 2008, Journal of Interventional Cardiac Electrophysiology.

[21]  D. Mark,et al.  Prognostic importance of defibrillator shocks in patients with heart failure. , 2008, The New England journal of medicine.

[22]  I. V. Van Gelder,et al.  Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study. , 2008, Journal of the American College of Cardiology.

[23]  E. Aliot,et al.  Automatic home monitoring of implantable cardioverter defibrillators. , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[24]  S. Priori,et al.  HRS/EHRA expert consensus on the monitoring of cardiovascular implantable electronic devices (CIEDs): description of techniques, indications, personnel, frequency and ethical considerations. , 2008, Heart rhythm.

[25]  Silvia G Priori,et al.  HRS/EHRA Expert Consensus on the Monitoring of Cardiovascular Implantable Electronic Devices (CIEDs): description of techniques, indications, personnel, frequency and ethical considerations: developed in partnership with the Heart Rhythm Society (HRS) and the European Heart Rhythm Association (EHRA) , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[26]  Wojciech Zareba,et al.  Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact. , 2008, Journal of the American College of Cardiology.

[27]  M. Santini,et al.  Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: impact on medical management and health-care resource utilization. , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[28]  A. Lazarus Remote, Wireless, Ambulatory Monitoring of Implantable Pacemakers, Cardioverter Defibrillators, and Cardiac Resynchronization Therapy Systems: Analysis of a Worldwide Database , 2007, Pacing and clinical electrophysiology : PACE.

[29]  H. Neuberger,et al.  Remote detection of incessant slow VT with an ICD capable of home monitoring. , 2006, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[30]  O. Ritter,et al.  Use of “IEGM Online” in ICD patients— , 2006, Clinical Research in Cardiology.

[31]  D. Cannom,et al.  Multicenter experience with failed and recalled implantable cardioverter-defibrillator pulse generators. , 2006, Heart rhythm.

[32]  L. Jordaens,et al.  The role of remote monitoring in the reduction of inappropriate implantable cardioverter defibrillator therapies , 2006, Clinical Research in Cardiology.

[33]  E. Toft,et al.  The RIONI study rationale and design: validation of the first stored electrograms transmitted via home monitoring in patients with implantable defibrillators. , 2006, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[34]  C. Stellbrink,et al.  Home Monitoring in an ICD patient with incessant ventricular tachycardia , 2005, Zeitschrift für Kardiologie.

[35]  B. Merkely,et al.  Clinical Experience with a New Detection Algorithm for Differentiation of Supraventricular from Ventricular Tachycardia in a Dual‐Chamber Defibrillator , 2004, Journal of cardiovascular electrophysiology.

[36]  D. Theuns,et al.  Home monitoring in ICD therapy: future perspectives. , 2003, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[37]  W. B. Fye,et al.  Cardiology workforce: there's already a shortage, and it's getting worse! , 2002, Journal of the American College of Cardiology.

[38]  A. Auricchio,et al.  Clinical relevance of stored electrograms for implantable cardioverter-defibrillator (ICD) troubleshooting and understanding of mechanisms for ventricular tachyarrhythmias. , 1996, The American journal of cardiology.

[39]  D. Schwartzman,et al.  Benefits and Lessons Learned From Stored Electrogram Information in Implantable Defibrillators , 1995, Journal of cardiovascular electrophysiology.

[40]  Hugo A. Katus,et al.  “Home monitoring” for early detection of implantable cardioverter-defibrillator failure , 2008, Clinical Research in Cardiology.

[41]  H. Trappe,et al.  IEGM-online based evaluation of implantable cardioverter defibrillator therapy appropriateness , 2006, Clinical Research in Cardiology.