Computerised measurements of QT dispersion in healthy subjects

Objective To assess the stability and reproducibility of computerised QT dispersion (QTd) measurement in healthy subjects, as this is presently being incorporated into commercial electrocardiographic systems. Methods 70 healthy volunteers (mean (SD) age 38 (10) years, 35 men, 35 women) with a normal 12 lead electrocardiogram (ECG) were studied. From each subject, 70 ECG recordings were taken using the MAC VU ECG recorder (Marquette). In study A, 50 ECGs were recorded in each subject: 10 supine, 10 sitting, 10 standing, 10 holding breath in maximum inspiration, and 10 holding breath in maximum expiration. After a mean interval of 8 (3) days (range 7 to 23), 10 recordings in supine and 10 in the standing position were repeated in each subject (study B). On measurements made using a research version of the commercial software without manual modification, the reproducibility of QTd was assessed by coefficient of variance (CV) and relative error, and comparisons made with other ECG indices. Results (1) QTd measurements were stable and not influenced by changes in posture and respiratory cycle; (2) there was no difference in QTd measurements between men and women, or between age groups dichotomised at 35 years; (3) no correlation was found between QTd and heart rate or QT interval; (4) short term reproducibility of all QTd measurements (CV 15.6% to 43.8%) was worse than that of conventional ECG indices (CV 1.4% to 5.3%); (5) long term reproducibility of QTd measurements (relative error 27.4% to 31.0%) was also worse than that of conventional ECG indices (relative error 1.8% to 7.9%) (p < 0.0001); (6) the reproducibility of QTd measurements tended to increase when several serial recordings were averaged. Conclusions Computerised measurements of global QTd and global QT-SD from 12 lead ECG by the MAC VU/QT Guard system are not significantly altered by changes in posture and respiration. The reproducibility of all QTd measurements is inferior to that of conventional ECG indices in healthy subjects.

[1]  A. Camm,et al.  Assessment of QT dispersion in symptomatic patients with congenital long QT syndromes. , 1992, The American journal of cardiology.

[2]  D. D. Bono,et al.  QT dispersion and mortality after myocardial infarction , 1995, The Lancet.

[3]  S. Cessie,et al.  Dispersion of ventricular repolarization and arrhythmic cardiac death in coronary artery disease. , 1994, The American journal of cardiology.

[4]  J. Leitch,et al.  QT Dispersion Does Not Predict Early Ventricular Fibrillation After Acute Myocardial Infarction , 1995, Pacing and clinical electrophysiology : PACE.

[5]  Qiuzhen Xue,et al.  New algorithms for QT dispersion analysis , 1996, Computers in Cardiology 1996.

[6]  D. Wyse,et al.  Precordial QT Interval Dispersion as a Marker of Torsade de Pointes: Disparate Effects of Class Ta Antiarrhythmic Drugs and Amiodarone , 1992, Circulation.

[7]  W. Grimm,et al.  QT dispersion and arrhythmic events in idiopathic dilated cardiomyopathy. , 1996, The American journal of cardiology.

[8]  S. Priori,et al.  Dispersion of the QT interval. A marker of therapeutic efficacy in the idiopathic long QT syndrome. , 1994, Circulation.

[9]  R. Cappato,et al.  Sympathetic and vagal influences on rate-dependent changes of QT interval in healthy subjects. , 1991, The American journal of cardiology.

[10]  K. Woods,et al.  Reproducibility and automatic measurement of QT dispersion. , 1996, European heart journal.

[11]  A Nava,et al.  Comparison of QT dispersion in hypertrophic cardiomyopathy between patients with and without ventricular arrhythmias and sudden death. , 1993, The American journal of cardiology.

[12]  A J Camm,et al.  Short‐and Long‐Term Reproducibility of QT, QTc, and QT Dispersion Measurement in Healthy Subjects , 1994, Pacing and clinical electrophysiology : PACE.

[13]  C. Lang,et al.  QT dispersion and sudden unexpected death in chronic heart failure , 1994, The Lancet.

[14]  S. Hohnloser,et al.  Variability of QT dispersion measurements in the surface electrocardiogram in patients with acute myocardial infarction and in normal subjects. , 1994, The American journal of cardiology.

[15]  J. Mccomb,et al.  QT dispersion: an indication of arrhythmia risk in patients with long QT intervals. , 1990, British heart journal.

[16]  Friedberg Ck Computers in cardiology. , 1970 .

[17]  A J Camm,et al.  Adjustment of QT dispersion assessed from 12 lead electrocardiograms for different numbers of analysed electrocardiographic leads: comparison of stability of different methods. , 1994, British heart journal.

[18]  D. Mirvis,et al.  Spatial variation of QT intervals in normal persons and patients with acute myocardial infarction. , 1985, Journal of the American College of Cardiology.

[19]  R. Tieleman,et al.  Increased dispersion of refractoriness in the absence of QT prolongation in patients with mitral valve prolapse and ventricular arrhythmias. , 1995, British heart journal.

[20]  A. Camm,et al.  QT-interval dispersion on 12-lead electrocardiogram in normal subjects: its reproducibility and relation to the T wave. , 1994, American heart journal.

[21]  E. Prystowsky,et al.  Influence of the autonomic nervous system on the Q-T interval in man. , 1982, The American journal of cardiology.

[22]  M. Malik,et al.  Interobserver Reproducibility of QT Interval Measurement and QT Dispersion in Patients After Acute Myocardial Infarction , 1996 .