The use of debonding microspheres in electrothermal debonding.

The aim of this study was to investigate if debonding microspheres (DM) could enhance electrothermal orthodontic debonding, and specifically to evaluate if the addition of DM, in varying concentrations to the orthodontic adhesive process, will affect bond strength. Bovine teeth (n=8) were mounted in acrylic using a silicone mould. Four test groups of three preparations of primer (Rely-a-Bond) with DM and a control were examined. Five incisor brackets were bonded to each tooth using the assigned primer and cold cure composite (Rely-a-Bond). Bracket tensile bond strength was measured in vitro in an Instron machine and recorded as debonding force (N). Differences between the groups were statistically analysed using analysis of variance, and repeatability was assessed. The mean debonding force of the control group was statistically significantly greater than all the other groups to which DM had been added (P<0.001). Comparison of the mean debonding forces of 1, 2.5, and 5 per cent concentrations of DM revealed no statistically significant difference between the groups. The addition of DM to orthodontic adhesive produced a highly statistically significant reduction in debonding force. There was no statistical difference in debonding force between varying concentrations of DM.

[1]  T Eliades,et al.  The inappropriateness of conventional orthodontic bond strength assessment protocols. , 2000, European journal of orthodontics.

[2]  L. Oesterle,et al.  The use of bovine enamel in bonding studies. , 1998, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[3]  W. Rock,et al.  Clinical performance of orthodontic brackets and adhesive systems: a randomized clinical trial. , 1998, British journal of orthodontics.

[4]  S. Littlewood,et al.  Use of jigs to standardise orthodontic bond testing. , 1998, Journal of dentistry.

[5]  J. Årtun,et al.  Risk of pulp damage due to temperature increase during thermodebonding of ceramic brackets. , 1997, European journal of orthodontics.

[6]  L. Lagerström,et al.  Electrothermal Debonding of Ceramic Brackets: An Ex Vivo Study , 1997 .

[7]  M. Harkness,et al.  Thermal debonding of ceramic brackets: an in vitro study. , 1997, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[8]  M. Nakata,et al.  Histologic investigation of the human pulp after thermodebonding of metal and ceramic brackets. , 1992, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[9]  S E Bishara,et al.  Comparisons of different debonding techniques for ceramic brackets: an in vitro study. Part II. Findings and clinical implications. , 1990, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[10]  S E Bishara,et al.  Comparisons of different debonding techniques for ceramic brackets: an in vitro study. Part I. Background and methods. , 1990, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[11]  F. Rueggeberg,et al.  Thermal debracketing of orthodontic resins. , 1990, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[12]  M. Iwaku,et al.  Bovine Teeth as Possible Substitutes in the Adhesion Test , 1983, Journal of dental research.

[13]  W J Houston,et al.  The analysis of errors in orthodontic measurements. , 1983, American journal of orthodontics.

[14]  H. Zander,et al.  Thermal Injury to Normal Dog Teeth: in Vivo Measurements of Pulp Temperature Increases and Their Effect on the Pulp Tissue , 1952, Journal of dental research.

[15]  S. Yankell,et al.  Clinical evaluations on thermal versus mechanical debonding of ceramic brackets. , 1991, The Journal of clinical dentistry.

[16]  J. Sheridan,et al.  Electrothermal debracketing. Part I. An in vitro study. , 1986, American journal of orthodontics.