Quantification of Biomechanical Interaction of Transcatheter Aortic Valve Stent Deployed in Porcine and Ovine Hearts

Success of the deployment and function in transcatheter aortic valve replacement is heavily reliant on the tissue–stent interaction. The present study quantified important tissue–stent contact variables of self-expanding transcatheter aortic valve stents when deployed into ovine and porcine aortic roots, such as the stent radial expansion force, stent pullout force, the annulus deformation response and the coefficient of friction on the tissue–stent contact interface. Braided Nitinol stents were developed, tested to determine stent crimped diameter vs. stent radial force from a stent crimp experiment, and deployed in vitro to quantify stent pullout, aortic annulus deformation, and the coefficient of friction between the stent and the aortic tissue from an aortic root–stent interaction experiment. The results indicated that when crimped at body temperature from 26 mm to 19, 21 and 23 mm stent radial forces were approximately 30–40% higher than those crimped at room temperature. Coefficients of friction leveled to approximately 0.10 ± 0.01 as stent wire diameter increased and annulus size decreased from 23 to 19 mm. Regardless of aortic annulus size and species tested, it appeared that a minimum of about 2.5 mm in annular dilatation, caused by about 60 N of radial force from stent expansion, was needed to anchor the stent against a pullout into the left ventricle. The study of the contact biomechanics in animal aortic tissues may help us better understand characteristics of tissue–stent interactions and quantify the baseline responses of non-calcified aortic tissues.

[1]  S. Wallace,et al.  Development and initial experimental evaluation of a prosthetic aortic valve for transcatheter placement. Work in progress. , 1992, Radiology.

[2]  T W Duerig,et al.  An Overview of Superelastic Stent Design , 2000, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[3]  F. Beyersdorf,et al.  Percutaneous aortic valve replacement: an experimental study. I. Studies on implantation. , 2002, The Journal of thoracic and cardiovascular surgery.

[4]  M. Leon,et al.  Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis First Human Case Description , 2002 .

[5]  M. Epstein,et al.  Cardiovascular Solid Mechanics: Cells, Tissues, and Organs , 2002 .

[6]  Assaf Bash,et al.  Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis: First Human Case Description , 2002, Circulation.

[7]  Tom Duerig,et al.  Self-expanding nitinol stents: material and design considerations , 2004, European Radiology.

[8]  Andrew L Rivard,et al.  The current state of in-vivo pre-clinical animal models for heart valve evaluation. , 2005, The Journal of heart valve disease.

[9]  Daniel Bia,et al.  Cryopreservation procedure does not modify human carotid homografts mechanical properties: an isobaric and dynamic analysis , 2005, Cell and Tissue Banking.

[10]  P. Bonhoeffer,et al.  Steps toward the percutaneous replacement of atrioventricular valves an experimental study. , 2005, Journal of the American College of Cardiology.

[11]  Q. Cao,et al.  The Cribier-Edwards™ percutaneous heart valve in the pulmonic position : initial animal experience , 2006 .

[12]  T. Mihaljevic,et al.  Transapical aortic valve implantation: an animal feasibility study. , 2006, The Annals of thoracic surgery.

[13]  Mirko Doss,et al.  Transapical approach for sutureless stent-fixed aortic valve implantation: experimental results. , 2006, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[14]  U. Gerckens,et al.  Percutaneous aortic valve replacement , 2006 .

[15]  O. Alfieri,et al.  Beating‐heart percutaneous mitral valve repair using a transcatheter endovascular suturing device in an animal model , 2007, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[16]  Lukas Altwegg,et al.  Percutaneous Transarterial Aortic Valve Replacement in Selected High-Risk Patients With Aortic Stenosis , 2007, Circulation.

[17]  M. Movahed Where are we going with percutaneous aortic valve replacement? , 2007, Expert review of cardiovascular therapy.

[18]  E. Tuzcu,et al.  iCoapsys mitral valve repair system: Percutaneous implantation in an animal model , 2008, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[19]  J. Gummert,et al.  Experimental evaluation of the JenaClip transcatheter aortic valve , 2009, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[20]  Xian-Xian Zhao,et al.  Use of a novel valve stent for transcatheter pulmonary valve replacement: an animal study. , 2009, The Journal of thoracic and cardiovascular surgery.

[21]  Liang Ge,et al.  Migration forces of transcatheter aortic valves in patients with noncalcific aortic insufficiency. , 2009, The Journal of thoracic and cardiovascular surgery.

[22]  L. Lécuyer,et al.  Increased radial force improves stent deployment in tricuspid but not in bicuspid stenotic native aortic valves. , 2010, The Annals of thoracic surgery.

[23]  Adriaan Moelker,et al.  Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful? , 2010, European heart journal.

[24]  Wei Sun,et al.  Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment. , 2010, Journal of biomechanics.

[25]  Fabian Nietlispach,et al.  Transapical transcatheter aortic valve implantation: follow-up to 3 years. , 2010, The Journal of thoracic and cardiovascular surgery.

[26]  T. Corbett,et al.  Determination of coefficient of friction for self-expanding stent-grafts. , 2010, Journal of biomechanical engineering.

[27]  Paul Schoenhagen,et al.  In Vivo Imaging and Computational Analysis of the Aortic Root. Application in Clinical Research and Design of Transcatheter Aortic Valve Systems , 2011, Journal of cardiovascular translational research.

[28]  Wei Sun,et al.  Significant differences in the material properties between aged human and porcine aortic tissues. , 2011, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[29]  A. Momen,et al.  Percutaneous Aortic Valve Replacement - A Review , 2011 .

[30]  Jean-Louis Vanoverschelde,et al.  EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. , 2011, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[31]  Wei Sun,et al.  Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment. , 2012, Journal of biomechanics.

[32]  D. Wood,et al.  Current status of transcatheter aortic valve replacement. , 2012, Journal of the American College of Cardiology.

[33]  Wei Sun,et al.  Biomechanical characterization of aortic valve tissue in humans and common animal models. , 2012, Journal of biomedical materials research. Part A.

[34]  Silvia Schievano,et al.  Patient-specific simulations of transcatheter aortic valve stent implantation , 2012, Medical & Biological Engineering & Computing.

[35]  Josep Rodés-Cabau,et al.  Transcatheter aortic valve implantation: current and future approaches , 2012, Nature Reviews Cardiology.

[36]  Thuy Pham,et al.  Comparison of biaxial mechanical properties of coronary sinus tissues from porcine, ovine and aged human species. , 2012, Journal of the mechanical behavior of biomedical materials.

[37]  S Tzamtzis,et al.  Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). , 2013, Medical engineering & physics.

[38]  小室 俊夫,et al.  Determination of coefficient of friction of lubricating oil , 2022 .