Characterization of Cryogen Spray Cooling With Thin-Film Thermocouple

Cryogen spray cooling (CSC) has been used effectively to protect the epidermis during laser dermatologic surgery. However, the temperature reduction in human skin induced by CSC has not been reliably determined due to the short cooling period and significant temperature gradient in the skin. Therefore, CSC has not been optimized for different laser dermatologic surgery procedures. Although it would be desirable to measure in situ human skin temperature, embedding a sensor within 100 μm beneath the skin surface is not feasible. In addition, infrared skin temperature measurement is also not workable because the skin is covered with a cryogen layer of unknown thickness. In this study, we selected an epoxy which has similar thermal properties to that of human skin as our cooling target. Thin-film thermocouples (TFTC) were deposited directly onto the epoxy substrate using micro-fabrication techniques to minimize the thermal contact resistance between TFTC and the substrate. The negligible mass of TFTC also creates a minimal disturbance to heat flow across the surface. Due to the difference in thermoelectric property between thin film and leading wire, special sensor design and calibration procedures were developed. TFTC were calibrated from −46 to 50°C. The thermoelectric sensitivity is around 50–60% of that of bulk material. Skin phantom temperature reductions produced by a commercial medical laser nozzle at different spray durations were measured using the TFTC. The results not only help to elucidate the mechanisms involved in interaction between cryogen spray and human skin but also provide a thermal boundary condition for numerical modeling of laser dermatologic surgery.Copyright © 2007 by ASME

[1]  Guo-xiang Wang,et al.  Heat-transfer dynamics during cryogen spray cooling of substrate at different initial temperatures , 2004, Physics in medicine and biology.

[2]  Guillermo Aguilar,et al.  Effect of spurt duration on the heat transfer dynamics during cryogen spray cooling , 2003, Physics in medicine and biology.

[3]  Guillermo Aguilar,et al.  Effects of mass flow rate and droplet velocity on surface heat flux during cryogen spray cooling , 2003, Physics in medicine and biology.

[4]  L. O. Svaasand,et al.  Intermittent cryogen spray cooling for optimal heat extraction during dermatologic laser treatment. , 2002, Physics in medicine and biology.

[5]  Wei Wang,et al.  Interfacial thermal conductance in rapid contact solidification process , 2002 .

[6]  B. Anvari,et al.  An analysis of heat removal during cryogen spray cooling and effects of simultaneous airflow application , 2001, Lasers in surgery and medicine.

[7]  Francis E. Kennedy,et al.  Thin film thermocouple arrays for sliding surface temperature measurement , 1997 .

[8]  B. S. Tanenbaum,et al.  Dynamic epidermal cooling during pulsed laser treatment of port-wine stain. A new methodology with preliminary clinical evaluation. , 1995, Archives of dermatology.

[9]  Raymond Holanda,et al.  Development of thin film thermocouples on ceramic materials for advanced propulsion system applications , 1992 .

[10]  Rointan F. Bunshah,et al.  Thin-film temperature sensors for gas turbine engines Problems and prospects , 1986 .

[11]  Kenneth G. Kreider,et al.  Thin film thermocouples for internal combustion engines , 1986 .

[12]  Stephen Semancik,et al.  Advanced thin film thermocouples , 1984 .

[13]  H. P. Grant,et al.  Turbine blade temperature measurements using thin film temperature sensors , 1981 .

[14]  A J Welch,et al.  Thin-film temperature sensors for biological measurements. , 1974, IEEE transactions on bio-medical engineering.

[15]  James W. Tunnell,et al.  Methodology for Estimation of Time-Dependent Surface Heat Flux due to Cryogen Spray Cooling , 2004, Annals of Biomedical Engineering.

[16]  B. S. Tanenbaum,et al.  Dynamic epidermal cooling in conjunction with laser‐induced photothermolysis of port wine stain blood vessels , 1996, Lasers in surgery and medicine.