Differential evolution applied for anticipatory load shedding with voltage stability considerations

Abstract This paper presents an anticipatory load shedding methodology which determines optimum load shedding at selected buses under emergency based on voltage stability. Accurate load shedding saves loss of revenue to power utility in addition to avoiding voltage instability problem. The buses for load shedding have been selected based on the sensitivity of minimum eigenvalue of load flow Jacobian with respect to load shed. A computational algorithm for minimum load shedding has been developed using DE. The algorithm accounts inequality constraints not only in present operating condition but also for predicted next interval load. Developed algorithm has been implemented on IEEE 6-bus and 14-bus test systems. Results have been compared with those obtained using particle swarm optimization (PSO) and its variant based on statistical inference.

[1]  S. S. Venkata,et al.  An adaptive approach to load shedding and spinning reserve control during underfrequency conditions , 1996 .

[2]  S. C. Choube,et al.  Loadability margin enhancement using co-ordinated aggregation based particle swarm optimization (CAPSO) , 2010 .

[3]  N. Hadjsaid,et al.  Emergency load shedding to avoid risks of voltage instability using indicators , 1994 .

[4]  C. W. Taylor Concepts of undervoltage load shedding for voltage stability , 1992 .

[5]  Y. Wallach,et al.  Calculations and Programs for Power System Networks , 1986 .

[6]  G. J. Berg,et al.  System loadability and load shedding , 1994 .

[7]  Xifan Wang,et al.  Determination of load shedding to provide voltage stability , 2011 .

[8]  M. Z. El-Sadek,et al.  Optimum load shedding for avoiding steady-state voltage instability , 1999 .

[9]  A. Wiszniewski,et al.  New Criteria of Voltage Stability Margin for the Purpose of Load Shedding , 2007, IEEE Transactions on Power Delivery.

[10]  Josef Tvrdík Adaptation in differential evolution: A numerical comparison , 2009, Appl. Soft Comput..

[11]  R. Storn,et al.  Differential Evolution: A Practical Approach to Global Optimization (Natural Computing Series) , 2005 .

[12]  S. M Chandekar,et al.  Revised load shedding schedule for power system incorporating the effect of transmission line performance , 2002 .

[13]  E.E.S. Lima A sensitivity analysis of eigenstructures [in power system dynamic stability] , 1997 .

[14]  Rene Feuillet,et al.  Adaptive under-voltage load shedding scheme using model predictive control , 2011 .

[15]  Bhujanga B. Chakrabarti,et al.  A preventive/corrective model for voltage stability incorporating dynamic load-shedding , 2003 .

[16]  J. W. Walker,et al.  Direct solutions of sparse network equations by optimally ordered triangular factorization , 1967 .

[17]  S. M. Shahidehpour,et al.  A Heuristic Approach to Load Shedding Scheme , 1989, IEEE Power Engineering Review.

[18]  Luis Rouco,et al.  A corrective load shedding scheme to mitigate voltage collapse , 2006 .

[19]  Rainer Storn,et al.  Differential Evolution – A Simple and Efficient Heuristic for global Optimization over Continuous Spaces , 1997, J. Glob. Optim..

[20]  Nasser Sadati,et al.  An enhanced under-voltage load-shedding scheme to provide voltage stability , 2007 .

[21]  P. R. Bijwe,et al.  Anticipatory load shedding scheme for loadability enhancement , 1999 .

[22]  Adly A. Girgis,et al.  Application of active power sensitivity to frequency and voltage variations on load shedding , 2010 .

[23]  W. Luan,et al.  Genetic algorithm for supply restoration and optimal load shedding in power system distribution networks , 2002 .

[24]  R. Storn,et al.  Differential Evolution - A simple and efficient adaptive scheme for global optimization over continuous spaces , 2004 .

[25]  G. Donner,et al.  An intelligent load shedding (ILS) system application in a large industrial facility , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..