Innovative algorithm to evaluate the capabilities of visual, near infrared, and infrared technologies for the detection of veins for intravenous cannulation.

Intravenous cannulation is the process of inserting a cannula into a vein to administrate medication, fluids, or to take blood samples. The process of identification and of locating veins plays an important role during the intravenous cannulation procedure to reduce health care costs and the suffering of patients. This paper compares the three technologies used to assess their suitability and capability for the detection of veins to support the cannulation process. Three types of cameras are used in this study; a visual, an infrared, and a near infrared. The collected images, 103 in total, from the three technologies have been analyzed using a wide range of image processing techniques and compared with identification templates to evaluate the performance of each technology. The results show that the near infrared technology supported by suitable LED illumination is the most effective for the visualization of veins. However, infrared thermography is found to be successful when followed by a cold stimulation.

[1]  W. Satz,et al.  Ultrasonography-guided peripheral intravenous access versus traditional approaches in patients with difficult intravenous access. , 2005, Annals of emergency medicine.

[2]  D Mbamalu,et al.  Methods of obtaining peripheral venous access in difficult situations , 1999, Postgraduate medical journal.

[3]  Kenneth W. Tobin,et al.  3D and multispectral imaging for subcutaneous veins detection. , 2009 .

[4]  Herke Jan Noordmans,et al.  The use of near-infrared light for safe and effective visualization of subsurface blood vessels to facilitate blood withdrawal in children. , 2013, Medical engineering & physics.

[5]  Joseph A. Shaw,et al.  The physics of near-infrared photography , 2013 .

[6]  E. Ring,et al.  Infrared thermal imaging in medicine , 2012, Physiological measurement.

[7]  M. Buono,et al.  Comparison of infrared versus contact thermometry for measuring skin temperature during exercise in the heat , 2007, Physiological measurement.

[8]  M. Tanner,et al.  Age Interactions in the Development of Naturally Acquired Immunity to Plasmodium falciparum and Its Clinical Presentation , 2007, PLoS Medicine.

[9]  Q. Yuan,et al.  Mouse blood vessel imaging by in-line x-ray phase-contrast imaging , 2008, Physics in medicine and biology.

[10]  Anuradha Godavarty,et al.  Functional near-infrared imaging reconstruction based on spatiotemporal features: venous occlusion studies , 2015 .

[11]  Dao-Qing Dai,et al.  Multilayer Surface Albedo for Face Recognition With Reference Images in Bad Lighting Conditions , 2014, IEEE Transactions on Image Processing.

[12]  J. Feldman,et al.  Ultrasonography-guided peripheral intravenous catheter survival in ED patients with difficult access. , 2010, The American journal of emergency medicine.

[13]  R Maniewski,et al.  Near-infrared spectroscopy in evaluation of cerebral oxygenation during vasovagal syncope. , 2004, Physiological measurement.

[14]  P. Ishimine,et al.  Randomized Controlled Trial of Ultrasound-Guided Peripheral Intravenous Catheter Placement Versus Traditional Techniques in Difficult-Access Pediatric Patients , 2009, Pediatric emergency care.

[15]  P. White,et al.  A comparison of technologies used for estimation of body temperature , 2010, Physiological measurement.

[16]  Yu-Kun Lai,et al.  Efficient Circular Thresholding , 2014, IEEE Transactions on Image Processing.

[17]  David L Wilson,et al.  Quantitative assessment of image quality enhancement due to unsharp-mask processing in x-ray fluoroscopy. , 2002, Journal of the Optical Society of America. A, Optics, image science, and vision.

[18]  Ian B Stewart,et al.  Does the technique employed for skin temperature assessment alter outcomes? A systematic review , 2015, Physiological measurement.