The operation of an inverter-assisted single-phase induction generator

The enhancement of the operability range of a stand-alone single-phase induction generator scheme with an inverter-battery system connected to the auxiliary winding is the theme of this paper. The reactive power requirement of the load connected to the main winding is met by the inverter system operating with either of two proposed pulsewidth modulation techniques, in the process of which the load voltage and frequency are regulated. The proposed schemes have potential application as power sources for autonomous systems and for utility interface to single-phase power system grids. Simulation and calculation results of the generator system connected to an impedance and motor loads, confirmed with some experimental results, are also set forth to validate some of the conclusions of the paper.

[1]  D.W. Novotny,et al.  Self-excitation in inverter driven induction machines , 1977, IEEE Transactions on Power Apparatus and Systems.

[2]  Olorunfemi Ojo Performance of self-excited single-phase induction generators with shunt, short-shunt and long-shunt excitation connections , 1996 .

[3]  C.-C. Liu,et al.  Dynamic modelling of battery energy storage system and application to power system stability , 1995 .

[4]  Abdulrahman I. Alolah,et al.  Performance of single phase induction generators , 1993 .

[5]  J. A. A. Melkebeek,et al.  Steady State Modelling of Regeneration and Self-Excitation in Induction Machines , 1983, IEEE Transactions on Power Apparatus and Systems.

[6]  S. S. Murthy,et al.  A novel self-induced self-regulated single phase induction generator. I. Basic system and theory , 1993 .

[7]  Jamia MWa islam A NOVEL SELF-EXCITED SELF-REGULATED SINGLE PHASE INDUCTION GENERATOR Part-ll : Experimental Investigation , 1993 .

[8]  Tadashi Fukao,et al.  Principles and Output Characteristics of Super High-Speed Reluctance Generator System , 1986, IEEE Transactions on Industry Applications.

[9]  Thomas A. Lipo,et al.  Series compensated PWM inverter with battery supply applied to an isolated induction generator , 1993, Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.

[10]  Olorunfemi Ojo,et al.  The operation of a stand-alone, single-phase induction generator using a single-phase, pulse-width modulated inverter with a battery supply , 1999 .

[11]  Olorunfemi Ojo The transient and qualitative performance of a self-excited single-phase induction generator , 1995 .