Ozone detection by differential absorption spectroscopy at ambient pressure with a 9.6 μm pulsed quantum-cascade laser

We report direct absorption spectroscopic detection of ozone at ambient pressure with a pulsed, DFB quantum-cascade laser (QCL) tuned within 1044–1050 cm-1 by temperature scanning. Wavelength calibration curves were derived from FTIR and CO2 spectra and interpreted with respect to the heat transfer from the heterostructure to the sink. The laser linewidth (∼0.13 cm-1 FWHM) was found to decrease with temperature, probably as a result of operation at constant current. Spurious spectral features due to baseline inaccuracies were successfully filtered out from the QCL O3 spectra using differential absorption. Reference O3 concentrations were obtained by applying the same method to UV spectra, simultaneously measured with a differential optical absorption spectrometer (DOAS). Column densities retrieved from QCL spectra are in fairly good agreement (±20%) with the DOAS values above 28 ppm m. The estimated QCL lowest detectable, absolute and differential absorptions, (7×10-3 and 2×10-3, respectively), entail effective detection limits of 14 and 25 ppm m, respectively. Ongoing improvements in the acquisition system should allow the achievement of detection limits at the level of commercial open-path DOAS systems (∼2 ppm m) in the near future. Our results demonstrate the applicability of the differential absorption method to QCL spectroscopy at ambient pressure, and encourage its use for open path detection.

[1]  O. Couach,et al.  An investigation of ozone and planetary boundary layer dynamics over the complex topography of Grenoble combining measurements and modeling , 2003 .

[2]  P. Thunis,et al.  Formulation and Evaluation of a Nonhydrostatic Mesoscale Vorticity Model (TVM) , 2000 .

[3]  J. Brion,et al.  Ozone UV spectroscopy I: Absorption cross-sections at room temperature , 1992 .

[4]  R. Bacis,et al.  THE OZONE MOLECULE : INFRARED AND MICROWAVE SPECTROSCOPY , 1998 .

[5]  M. Beck,et al.  Photoacoustic spectroscopy with quantum cascade distributed-feedback lasers. , 2001, Optics letters.

[6]  Armin Lambrecht,et al.  Fast gas spectroscopy using pulsed quantum cascade lasers , 2003 .

[7]  Federico Capasso,et al.  Thermoelectrically cooled quantum-cascade-laser-based sensor for the continuous monitoring of ambient atmospheric carbon monoxide. , 2002, Applied optics.

[8]  S. Schilt,et al.  Ethylene spectroscopy using a quasi-room-temperature quantum cascade laser. , 2002, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[9]  M. Zahniser,et al.  Sub-part-per-billion detection of nitric oxide in air using a thermoelectrically cooled mid-infrared quantum cascade laser spectrometer , 2002 .

[10]  M. Beck,et al.  Chemical sensing with pulsed QC-DFB lasers operating at 15.6 μm , 2002, Applied physics. B, Lasers and optics.

[11]  S. Perego Metphomod – a Numerical Mesoscale Model for Simulation of Regional Photosmog in Complex Terrain: Model Description and Application During Pollumet 1993 (Switzerland) , 1999 .

[12]  U. Platt,et al.  Numerical analysis and estimation of the statistical error of differential optical absorption spectroscopy measurements with least-squares methods. , 1996, Applied optics.

[13]  F. Capasso,et al.  Quantum-cascade laser measurements of stratospheric methane and nitrous oxide. , 2001, Applied optics.

[14]  U. Platt,et al.  Differential optical absorption spectroscopy (DOAS) , 1994 .

[15]  Laurence S. Rothman,et al.  Reprint of: The HITRAN molecular spectroscopic database and HAWKS (HITRAN Atmospheric Workstation): 1996 edition , 1998 .

[16]  Serge Luryi,et al.  Theory of gain spectra for quantum cascade lasers and temperature dependence of their characteristics at low and moderate carrier concentrations , 1996 .