Relation of external surface to internal tumor motion studied with cine CT.

The accuracy of delivering gated-radiation therapy to lung tumors using an external respiratory surrogate relies on not only interfractional and intrafractional reproducibility, but also a strong correlation between external motion and internal tumor motion. The purpose of this work was to use the cine images acquired by four-dimensional computed tomography acquisition protocol to study the relation between external surface motion and internal tumor motion. The respiratory phase information of tumor motion and chest wall motion was measured on the cine images using a proposed region-of-interest (ROI) method and compared to measurement of an external respiratory monitoring device. On eight lung patient data sets, the phase shifts were measured between (1) the signal of a real-time positioning-management (RPM) respiratory monitoring device placed in the abdominal region and four surface locations on the chest wall, (2) the RPM signal in the abdominal region and tumor motions, and (3) chest wall surface motions and tumor motions. Respiratory waveforms measured at different surface locations during the same respiratory cycle often varied and had significant phase shifts. Seven of the 8 patients showed the abdominal motion leading chest wall motion. The best correlation (smallest phase shift) was found between the abdominal motion and the superior-inferior (S-I) tumor motion. A wide range of phase shifts was observed between external surface motion and tumor anterior-posterior (A-P)/lateral motion. The result supported the placement of the RPM block in the abdominal region and suggested that during a gated therapy utilizing the RPM system, it is necessary to place the RPM block at the same location as it is during treatment simulation in order to reduce potential errors introduced by the position of the RPM block. Correlations between external motions and lateral/A-P tumor motions were inconclusive due to a combination of patient selection and the limitation of the ROI method.

[1]  Thomas Flohr,et al.  Four-dimensional multislice computed tomography for determination of respiratory lung tumor motion in conformal radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[2]  Eric C Ford,et al.  Measurement of lung tumor motion using respiration-correlated CT. , 2004, International journal of radiation oncology, biology, physics.

[3]  R. Mohan,et al.  Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker. , 2003, Medical physics.

[4]  G Starkschall,et al.  Respiratory-driven lung tumor motion is independent of tumor size, tumor location, and pulmonary function. , 2001, International journal of radiation oncology, biology, physics.

[5]  C. Ling,et al.  Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. , 2002, Medical physics.

[6]  Tinsu Pan,et al.  Four-dimensional computed tomography: image formation and clinical protocol. , 2005, Medical physics.

[7]  George T. Y. Chen,et al.  Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. , 2005, International journal of radiation oncology, biology, physics.

[8]  Shinichi Shimizu,et al.  Intrafractional tumor motion: lung and liver. , 2004, Seminars in radiation oncology.

[9]  T. Guerrero,et al.  Acquiring 4D thoracic CT scans using a multislice helical method. , 2004, Physics in medicine and biology.

[10]  R. Mohan,et al.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. , 2003, Physics in medicine and biology.

[11]  Jean-Philippe Pignol,et al.  Correlation of lung tumor motion with external surrogate indicators of respiration. , 2004, International journal of radiation oncology, biology, physics.

[12]  G. Christensen,et al.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. , 2003, Medical physics.

[13]  Steve B. Jiang,et al.  Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates , 2005, Physics in medicine and biology.

[14]  Achim Schweikard,et al.  Respiration tracking in radiosurgery. , 2004, Medical physics.

[15]  Y. Tsunashima,et al.  Correlation between the respiratory waveform measured using a respiratory sensor and 3D tumor motion in gated radiotherapy. , 2004, International journal of radiation oncology, biology, physics.

[16]  Suresh Senan,et al.  Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer. , 2004, International journal of radiation oncology, biology, physics.

[17]  Radhe Mohan,et al.  Patient training in respiratory-gated radiotherapy. , 2003, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.