Towards a gastric pH-sensor: an optrode for the pH 0–7 range

SummaryThis work describes the development of the first optical pH-sensor capable of measuring pH-values in the 0–7 range. The pH-sensitive material consists of fibrous amino-ethyl cellulose onto which fluorescein and eosin were covalently immobilised. Fluorescein was immobilised via its isothiocyanate, and immobilised eosin was obtained by bromination of the immobilised fluorescein. The material thus obtained was mechanically fixed at the end of a bifurcated optical fibre bundle. Fluorescence was excited at 490 nm and measured at >540 nm. The accuracy of the sensor is ±0.05 pH units, its response time ranges from 25 to 30 s. Practically no signal loss was observed upon constant illumination over periods of more than 15 h.

[1]  W. Rudolf Seitz,et al.  pH sensor based on immobilized fluoresceinamine , 1982 .

[2]  David R. Walt,et al.  Physiological pH fiber-optic chemical sensor based on energy transfer , 1987 .

[3]  T. P. Jones,et al.  Optical pH sensor based on the chemical modification of a porous polymer film , 1988 .

[4]  Otto S. Wolfbeis,et al.  A new group of fluorescent pH-indicators for an extended pH-range , 1987 .

[5]  Noeller Hg,et al.  The endoradio sound for electrical pH measurement in the stomach and its clinical significance , 1960 .

[6]  David R. Walt,et al.  Polymer Modification of Fiber Optic Chemical Sensors as a Method of Enhancing Fluorescence Signal for pH Measurement , 1986 .

[7]  P. Millán,et al.  Study of a pH sensitive optical fibre sensor based on the use of cresol red , 1986 .

[8]  N. Opitz,et al.  New fluorescence photometrical techniques for simultaneous and continuous measurements of ionic strength and hydrogen ion activities , 1983 .

[9]  Ramaier Narayanaswamy,et al.  Optical fibre sensors for chemical species , 1988 .

[10]  P. Dasgupta,et al.  Tubular microporous membrane entrapped enzyme reactors for flow injection analysis , 1987 .

[11]  J. Janata Do optical sensors really measure pH , 1987 .

[12]  Ramaier Narayanaswamy,et al.  Fibre-optic pH probe based on the use of an immobilised colorimetric indicator , 1984 .

[13]  Gary D. Christian,et al.  Single fibre optic fluorescence pH probe , 1987 .

[14]  W. Rudolf Seitz,et al.  A fluorescence sensor for quantifying pH in the range from 6.5 to 8.5 , 1984 .

[15]  P. Elving,et al.  Preparation of Buffer Systems of Constant Ionic Strength , 1956 .

[16]  S R Goldstein,et al.  Fiber optic pH probe for physiological use. , 1980, Analytical chemistry.

[17]  Helmut Offenbacher,et al.  Fluorescence optical sensors for continuous determination of near-neutral pH values , 1986 .