Quantitative Analysis of Parkinsonian Tremor in a Clinical Setting Using Inertial Measurement Units

Background Parkinson's disease (PD) is a neurodegenerative disorder that affects human voluntary movements. Tremor is one of the most common symptoms of PD and is expressed as involuntary oscillation of the body. Tremors can be analysed in the frequency domain. Objective The aim of the current study was to examine selected tremor parameters (frequency, root mean square, and approximated entropy) in order to quantify the characteristics of patients diagnosed with PD, compared to a healthy control group, and to compare the parameters by dividing the subjects according to UPDRS assessment. Methods The subjects were divided into two groups: a group of people diagnosed with PD (n = 19) and a control group consisting of healthy volunteers (CO = 12). Each subject performed motor tasks specific to certain tremors: the finger-to-nose test. Each subject performed a motor task three times. A nine degree of freedom (DOF) wireless inertial measurement unit was used for the measurement of upper limb motor tasks. For the quantitative estimation of kinetic and postural tremors, dominant frequency, root means square, and approximation entropy were selected and calculated from the measured angular velocity and linear acceleration signals. A one-way ANOVA with a significance level of α = 0.05 was used to test the null hypothesis that the means of the tremor metrics were the same between the PD and CO groups. Results Statistically significant differences between PD patients and control groups were observed in ApEn acceleration signal of kinetic tremor, ApEn angular velocity signal of kinetic tremor, ApEn angular velocity of postural tremor, frequency acceleration signal of postural tremor, and RMS angular speed kinetic tremor. Conclusion Application of inertial measurement units for clinical research of patients and PD tremor evaluation allows providing quantitative information for diagnostic purposes, during screening in a clinical setting that differentiates between PD patients and controls.

[1]  Ronachai Pongthornseri,et al.  Support vector machine classification of Parkinson's disease and essential tremor subjects based on temporal fluctuation , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[2]  Giuliana Grimaldi,et al.  Neurological Tremor: Sensors, Signal Processing and Emerging Applications , 2010, Sensors.

[3]  J. Jankovic,et al.  Correlation between Kinesia system assessments and clinical tremor scores in patients with essential tremor , 2010, Movement disorders : official journal of the Movement Disorder Society.

[4]  K. Chon,et al.  Approximate entropy for all signals , 2009, IEEE Engineering in Medicine and Biology Magazine.

[5]  Dimitrios I. Fotiadis,et al.  Real-time quantification of resting tremor in the Parkinson's disease , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[6]  Barbara Wilk,et al.  Assessment of a hand tremor based on analysis of the accelerometer signal , 2016 .

[7]  Christian Duval,et al.  Rest and postural tremors in patients with Parkinson's disease , 2006, Brain Research Bulletin.

[8]  Ronachai Pongthornseri,et al.  Temporal fluctuations of tremor signals from inertial sensor: a preliminary study in differentiating Parkinson’s disease from essential tremor , 2015, Biomedical engineering online.

[9]  James McNames,et al.  Continuous At-Home Monitoring of Tremor in Patients with Parkinson's Disease , 2010 .

[10]  N. Sriraam,et al.  Automated Detection of PD Resting Tremor Using PSD with Recurrent Neural Network Classifier , 2010, 2010 International Conference on Advances in Recent Technologies in Communication and Computing.

[11]  Tim Lüth,et al.  Quantitative Assessment of Parkinsonian Tremor Based on an Inertial Measurement Unit , 2015, Sensors.

[12]  Pedro L. Melo,et al.  Analysis of human tremor in patients with Parkinson disease using entropy measures of signal complexity , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[13]  B. Schelter,et al.  Spectral and Higher-Order-Spectral Analysis of Tremor Time Series , 2014 .

[14]  Elan D. Louis,et al.  Postural and Intention Tremors: A Detailed Clinical Study of Essential Tremor vs. Parkinson’s Disease , 2013, Front. Neurol..

[15]  T. Zesiewicz,et al.  Quantitative Analysis of Tremors in Welders , 2011, International journal of environmental research and public health.

[16]  B. Abhinaya,et al.  Feature Extraction and Selection of a Combination of Entropy Features for Real-time Epilepsy Detection , 2016 .

[17]  S M Rissanen,et al.  EMG signal morphology and kinematic parameters in essential tremor and Parkinson's disease patients. , 2014, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[18]  Apichart Intarapanich,et al.  Tremor assessment using spiral analysis in time-frequency domain , 2013, 2013 Proceedings of IEEE Southeastcon.

[19]  Tjitske Heida,et al.  Power spectral density analysis of physiological, rest and action tremor in Parkinson’s disease patients treated with deep brain stimulation , 2013, Journal of NeuroEngineering and Rehabilitation.

[20]  Kamiar Aminian,et al.  Quantification of Tremor and Bradykinesia in Parkinson's Disease Using a Novel Ambulatory Monitoring System , 2007, IEEE Transactions on Biomedical Engineering.