Attenuation correction of myocardial SPECT perfusion images with low-dose CT: evaluation of the method by comparison with perfusion PET.

UNLABELLED In cardiac SPECT, specificity is significantly affected by artifacts due to photon absorption. As the success of attenuation correction depends mainly on high-quality attenuation maps, SPECT low-dose CT devices are promising. We wanted to evaluate the usefulness of a SPECT low-dose CT device in myocardial perfusion scintigraphy. For the evaluation of attenuation correction systems, primarily comparisons with coronary angiography are used. Because the comparison of a method showing myocardial perfusion with an investigation displaying the morphology of vessels yields some difficulties, we chose perfusion PET with (13)N-ammonia as the reference method. METHODS We prospectively analyzed 23 patients (6 women, 17 men) with known or suspected coronary artery disease. Rest studies and studies under pharmacologic stress with adenosine were performed. After simultaneous injection of (13)N-ammonia and (99m)Tc-sestamibi, a dynamic PET acquisition was started. The SPECT study was performed about 2 h later. Based on 20-segment polar maps, SPECT with and without attenuation correction was compared with PET-derived perfusion values and ammonia uptake values. The PET uptake images were also smoothed to adjust their resolution to the resolution of the SPECT images. RESULTS The concordance of SPECT and PET studies was improved after attenuation correction. The main effect was seen in the inferior wall. Especially in the apex and anterolateral wall, there were differences between SPECT and PET studies not attributable to attenuation artifacts. Because these differences diminished after smoothing of the PET studies, they might be due to partial-volume effects caused by the inferior resolution of the SPECT images. CONCLUSION The x-ray-derived attenuation correction leads to SPECT images that represent myocardial perfusion more accurately than nonattenuation-corrected SPECT images. The benefit of the method is seen primarily in the inferior wall. The low resolution of the SPECT system may lead to artifacts due to partial-volume effects. This phenomenon must be considered when perfusion PET is used as a reference method to investigate the effect of attenuation correction.

[1]  Samuel Sideman,et al.  Regional three-dimensional geometry of the normal human left ventricle using cine computed tomography , 1996, Annals of Biomedical Engineering.

[2]  C. Pizzi,et al.  Endothelial Function Predicts Future Development of Coronary Artery Disease: A Study of Women With Chest Pain and Normal Coronary Angiograms , 2004, Circulation.

[3]  D E Kuhl,et al.  Noninvasive quantification of regional blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imaging. , 1990, Journal of the American College of Cardiology.

[4]  G. Hutchins,et al.  Metabolic fate of [13N]ammonia in human and canine blood. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  K. Gould,et al.  Clinical cardiac positron emission tomography: state of the art. , 1991, Circulation.

[6]  E. Ficaro,et al.  Attenuation correction for single photon emission computed tomography myocardial perfusion imaging , 2004, Current cardiology reports.

[7]  J. Sýkora,et al.  Attenuation-corrected thallium-201 single-photon emission tomography using a gadolinium-153 moving line source: clinical value and the impact of attenuation correction on the extent and severity of perfusion abnormalities , 1998, European Journal of Nuclear Medicine.

[8]  R. Kluge,et al.  Non-Uniform Attenuation Correction for Myocardial SPET Using Two Gd-153 Line Sources , 1996, Nuklearmedizin.

[9]  P. Jarritt,et al.  Effect of attenuation correction on myocardial thallium-201 distribution in patients with a low likelihood of coronary artery disease , 1997, European Journal of Nuclear Medicine.

[10]  T Sharir,et al.  Evaluation of an attenuation correction method for thallium-201 myocardial perfusion tomographic imaging of patients with low likelihood of coronary artery disease , 1998, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[11]  E. Hoffman,et al.  Noninvasive assessment of coronary stenoses by myocardial imaging during pharmacologic coronary vasodilation. VI. Detection of coronary artery disease in human beings with intravenous N-13 ammonia and positron computed tomography. , 1982, The American journal of cardiology.

[12]  D. Kuhl,et al.  N‐13 Ammonia as an Indicator of Myocardial Blood Flow , 1981, Circulation.

[13]  A. Alavi,et al.  Improved uniformity in tomographic myocardial perfusion imaging with attenuation correction and enhanced acquisition and processing. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  Michael Wilk,et al.  Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images , 2000, European Journal of Nuclear Medicine.

[15]  Brad Kemp,et al.  A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models. , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[16]  S. Port Imaging guidelines for nuclear cardiology procedures , 1999 .

[17]  S. Bergmann,et al.  Normal limits for left ventricular ejection fraction and volumes estimated with gated myocardial perfusion imaging in patients with normal exercise test results: Influence of tracer, gender, and acquisition camera , 2000, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[18]  G Germano,et al.  Quantitative analysis of regional motion and thickening by gated myocardial perfusion SPECT: normal heterogeneity and criteria for abnormality. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  Habib Zaidi,et al.  Determination of the attenuation map in emission tomography. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  E. Hoffman,et al.  Noninvasive assessment of coronary stenoses with myocardial perfusion imaging during pharmacologic coronary vasodilatation. V. Detection of 47 percent diameter coronary stenosis with intravenous nitrogen-13 ammonia and emission-computed tomography in intact dogs. , 1978, The American journal of cardiology.

[21]  N. Mullani,et al.  A precise, three-dimensional atlas of myocardial perfusion correlated with coronary arteriographic anatomy , 2001, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[22]  R. Kluge,et al.  Attenuation correction by simultaneous emission-transmission myocardial single-photon emission tomography using a technetium-99m-labelled radiotracer: impact on diagnostic accuracy , 1997, European Journal of Nuclear Medicine.

[23]  T. Bateman,et al.  Attenuation correction single-photon emission computed tomography myocardial perfusion imaging. , 2005, Seminars in nuclear medicine.

[24]  Y. Cottin,et al.  Quantitative myocardial thallium single-photon emission computed tomography in normal women: Demonstration of age-related differences , 2005, European Journal of Nuclear Medicine.

[25]  S. Bergmann,et al.  Myocardial perfusion imaging agents: SPECT and PET , 2004, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[26]  G V Heller,et al.  Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging. , 1999, Circulation.

[27]  B. Nowak,et al.  Comparison of regional myocardial blood flow and perfusion in dilated cardiomyopathy and left bundle branch block: role of wall thickening. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[28]  J. Fessler,et al.  Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission computed tomography. , 1996, Circulation.

[29]  R. Hendel,et al.  The value and practice of attenuation correction for myocardial perfusion SPECT imaging: a joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine. , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[30]  N. Mullani,et al.  Assessment of coronary artery disease severity by positron emission tomography. Comparison with quantitative arteriography in 193 patients. , 1989, Circulation.

[31]  J van den Hoff,et al.  [1-(11)C]Acetate as a quantitative perfusion tracer in myocardial PET. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[32]  N Tonami,et al.  Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.