Single Event Upset Characterization of GHz Analog to Digital Converters with Dynamic Inputs Using a Beat Frequency Test Method

Typically, single event upset (SEU) testing of analog to digital converters (ADC) has been done with static inputs. A test method, using a beat frequency and code error detection software, is presented. This test method allows for SEU characterization of ultra high speed ADC's, using dynamic inputs that more closely reflect the operating conditions in a space application. The test method is demonstrated on National Semiconductor's ADC08D1000WG-QV at 1 gigasample per second (GSPS) and an input frequency close to 1 GHz. A discussion of the SEU signatures and error rates are also presented.

[1]  R.C. Taft,et al.  A 1.8-V 1.6-GSample/s 8-b self-calibrating folding ADC with 7.26 ENOB at Nyquist frequency , 2004, IEEE Journal of Solid-State Circuits.

[2]  D. J. Wilson,et al.  Characterization of single event effects for the AD677, 16-bit A/D converter , 1994, Workshop Record. 1994 IEEE Radiation Effects Data Workshop.

[3]  Paul W. Marshall,et al.  Proton-induced single event upset characterization of a 1 Giga-sample per second analog to digital converter , 1999, 1999 Fifth European Conference on Radiation and Its Effects on Components and Systems. RADECS 99 (Cat. No.99TH8471).

[4]  Andrzej Cichocki,et al.  Fundamentals of Sampled-Data Systems , 1989 .

[5]  T. L. Turflinger,et al.  Single-event effects in analog and mixed-signal integrated circuits , 1996 .