Reduced field of view MRI with rapid, B1‐robust outer volume suppression

MRI scans are inefficient when the size of the anatomy under investigation is small relative to the subject's full extent. The field of view must be expanded, and acquisition times accordingly prolonged. Shorter scans are feasible with reduced field of view imaging (rFOV) using outer volume suppression (OVS), a magnetization preparation sequence that attenuates signal outside a region of interest (ROI). This work presents a new OVS sequence with a cylindrical ROI, short duration, and improved tolerance for B  1+ inhomogeneity. The sequence consists of a nonselective adiabatic tipdown pulse, which provides B  1+ ‐robust signal suppression, and a fast 2D spiral cylindrical tipback pulse. Analysis of the Bloch equations with transverse initial magnetization reveals a conjugate symmetric constraint for tipback pulses with small flip angles. This property is exploited to achieve two‐shot performance from the single‐shot tipback pulse. The OVS sequence is validated in phantoms and in vivo with multislice spiral imaging at 3 T. The relative signal‐to‐noise ratio efficiency of the proposed sequence was 98% in a phantom and 75–90% in vivo. The effectiveness is demonstrated with cardiovascular rFOV imaging, which exhibits improved resolution and reduced artifacts compared to conventional, full field of view imaging. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.

[1]  Evert-Jan Vonken,et al.  Simultaneous B0‐ and B1+‐Map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T , 2010, Magnetic resonance in medicine.

[2]  J. Pauly,et al.  A homogeneity correction method for magnetic resonance imaging with time-varying gradients. , 1991, IEEE transactions on medical imaging.

[3]  Albert Macovski,et al.  A k-space analysis of small-tip-angle excitation. 1989. , 2011, Journal of magnetic resonance.

[4]  T. Parrish,et al.  3-D FLASH imaging using a single surface coil and a new adiabatic pulse, BIR-4. , 1990, Investigative radiology.

[5]  P. Boesiger,et al.  Equi-ripple design of quadratic-phase RF pulses. , 2004, Journal of magnetic resonance.

[6]  Weiran Deng,et al.  A three‐dimensional variable‐density spiral spatial‐spectral RF pulse with rotated gradients , 2010, Magnetic resonance in medicine.

[7]  Douglas C Noll,et al.  Multishot 3D slice‐select tailored RF pulses for MRI , 2002, Magnetic resonance in medicine.

[8]  Michael Garwood,et al.  Symmetric pulses to induce arbitrary flip angles with compensation for rf inhomogeneity and resonance offsets , 1991 .

[9]  J. Pauly,et al.  Simultaneous spatial and spectral selective excitation , 1990, Magnetic resonance in medicine.

[10]  G C McKinnon,et al.  Optimized outer volume suppression for single‐shot fast spin‐echo cardiac imaging , 1998, Journal of magnetic resonance imaging : JMRI.

[11]  M. Garwood,et al.  Adiabatic pulses , 1997, NMR in biomedicine.

[12]  René M. Botnar,et al.  Noninvasive Coronary Vessel Wall and Plaque Imaging With Magnetic Resonance Imaging , 2000, Circulation.

[13]  R. Hoge,et al.  Density compensation functions for spiral MRI , 1997, Magnetic resonance in medicine.

[14]  P Börnert,et al.  Interactive reduced FOV imaging for projection reconstruction and spiral acquisition. , 2001, Magnetic resonance imaging.

[15]  Alan V. Oppenheim,et al.  Discrete-time Signal Processing. Vol.2 , 2001 .

[16]  P. Boesiger,et al.  Reduced field‐of‐view MRI using outer volume suppression for spinal cord diffusion imaging , 2007, Magnetic resonance in medicine.

[17]  J A Frank,et al.  Simple correction method for k-space trajectory deviations in MRI. , 1998, Journal of magnetic resonance.

[18]  H. Rinneberg,et al.  Human cardiac imaging at 3 T using phased array coils , 2000, Magnetic resonance in medicine.

[19]  D Chien,et al.  Fast selective black blood MR imaging. , 1991, Radiology.

[20]  M. Stuber,et al.  Right coronary artery flow velocity and volume assessment with spiral K‐space sampled breathhold velocity‐encoded MRI at 3 tesla: Accuracy and reproducibility , 2010, Journal of magnetic resonance imaging : JMRI.

[21]  Krishna S Nayak,et al.  Design and use of tailored hard‐pulse trains for uniformed saturation of myocardium at 3 Tesla , 2008, Magnetic resonance in medicine.

[22]  M. Bronskill,et al.  T1, T2 relaxation and magnetization transfer in tissue at 3T , 2005, Magnetic resonance in medicine.

[23]  A Haase,et al.  Localization of unaffected spins in NMR imaging and spectroscopy (LOCUS spectroscopy) , 1986, Magnetic resonance in medicine.

[24]  Reza Nezafat,et al.  B1‐insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 T , 2006, Magnetic resonance in medicine.

[25]  G. Glover,et al.  Restricted field of view magnetic resonance imaging of a dynamic time series , 2007, Magnetic resonance in medicine.

[26]  L DelaBarre,et al.  BISTRO: An outer‐volume suppression method that tolerates RF field inhomogeneity , 2001, Magnetic resonance in medicine.