Novel Spectral Interval Selection Method Based on Synchronous Two-Dimensional Correlation Spectroscopy

Synchronous 2D correlation spectroscopy was first proposed to select informational spectral intervals in PLS calibration. The proposed method could extract the spectral intervals related to analyte. The results of its application to NIR/PLS determination of quercetin in extract of Ginkgo biloba leaves showed that the proposed method could find out an optimized region with which one could improve the performance of the corresponding PLS model, in terms of low prediction error, root mean square error of prediction (RMSEP), and comparing with the result obtained using whole spectra and interval PLS.

[1]  I. Noda Generalized Two-Dimensional Correlation Method Applicable to Infrared, Raman, and other Types of Spectroscopy , 1993 .

[2]  C. Spiegelman,et al.  Theoretical Justification of Wavelength Selection in PLS Calibration:  Development of a New Algorithm. , 1998, Analytical Chemistry.

[3]  S. Engelsen,et al.  Interval Partial Least-Squares Regression (iPLS): A Comparative Chemometric Study with an Example from Near-Infrared Spectroscopy , 2000 .

[4]  I. Noda,et al.  Determination of Two-Dimensional Correlation Spectra Using the Hilbert Transform , 2000 .

[5]  A. E. Dowrey,et al.  Generalized Two-Dimensional Correlation Spectroscopy , 2000 .

[6]  Jean-Pierre Gauchi,et al.  Comparison of selection methods of explanatory variables in PLS regression with application to manufacturing process data , 2001 .

[7]  Yukihiro Ozaki,et al.  New Insight into the Mathematical Background of Generalized Two-Dimensional Correlation Spectroscopy and the Influence of Mean Normalization Pretreatment on Two-Dimensional Correlation Spectra , 2001 .

[8]  M. C. U. Araújo,et al.  The successive projections algorithm for variable selection in spectroscopic multicomponent analysis , 2001 .

[9]  A. Höskuldsson Variable and subset selection in PLS regression , 2001 .

[10]  M. Fukushima,et al.  Determination of the Intrinsic Stability Constants of Toxic Divalent Metal Ions to Alginic Acid , 2001, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[11]  Two-Dimensional Correlation Spectroscopy in Analytical Chemistry , 2002 .

[12]  S. Wold,et al.  Wavelength interval selection in multicomponent spectral analysis by moving window partial least-squares regression with applications to mid-infrared and near-infrared spectroscopic data. , 2002, Analytical chemistry.

[13]  Jean-Pierre Gauchi,et al.  Selecting both latent and explanatory variables in the PLS1 regression model , 2003 .

[14]  R. Leardi,et al.  Sequential application of backward interval partial least squares and genetic algorithms for the selection of relevant spectral regions , 2004 .

[15]  Jian-hui Jiang,et al.  Spectral regions selection to improve prediction ability of PLS models by changeable size moving window partial least squares and searching combination moving window partial least squares , 2004 .

[16]  B. Nadler,et al.  The prediction error in CLS and PLS: the importance of feature selection prior to multivariate calibration , 2005 .

[17]  Michel Verleysen,et al.  Mutual information for the selection of relevant variables in spectrometric nonlinear modelling , 2006, ArXiv.

[18]  Michel Verleysen,et al.  Fast Selection of Spectral Variables with B-Spline Compression , 2007, ArXiv.

[19]  Jian-hui Jiang,et al.  MCCV stacked regression for model combination and fast spectral interval selection in multivariate calibration , 2007 .

[20]  C. Ruckebusch,et al.  Genetic algorithm optimisation combined with partial least squares regression and mutual information variable selection procedures in near-infrared quantitative analysis of cotton-viscose textiles. , 2007, Analytica chimica acta.

[21]  Zou Xiaobo,et al.  Use of FT-NIR spectrometry in non-invasive measurements of soluble solid contents (SSC) of ‘Fuji’ apple based on different PLS models , 2007 .