Implementation of intensity-modulated laser diodes in time-resolved, pump-probe fluorescence microscopy.

We present the implementation of intensity-modulated laser diodes for applications in frequency-domain pump-probe fluorescence microscopy. Our technique, which is based on the stimulated-emission approach, uses two sinusoidally modulated laser diodes. One laser (635 nm) excites the chromophores under study, and the other laser (680 nm) is responsible for inducing stimulated emission from excited-state molecules. Both light sources are modulated in the 80-MHz range but with an offset of 5 kHz between them. The result of the interaction of the pump and the probe beams is that a cross-correlation fluorescence signal at 5 kHz is generated primarily at the focal volume. Microscope imaging at the cross-correlation signal results in images with high contrast, and time-resolved high-frequency information can be acquired without high-speed detection. A detailed experimental arrangement of our methodology is presented along with images acquired from a 4.0-mum-diameter fluorescent sphere and TOTO-3-labeled mouse STO cells. (TOTO-3 is a nucleic acid stain.) Our results demonstrate the feasibility of using sinusoidally modulated laser diodes for pump-probe imaging, creating the exciting possibility of high-contrast time-resolved imaging with low-cost laser-diode systems.

[1]  P. So,et al.  Time-resolved polarization imaging by pump-probe (stimulated emission) fluorescence microscopy. , 2000, Biophysical journal.

[2]  M M Murnane,et al.  Sub-10-fs operation of Kerr-lens mode-locked lasers. , 1996, Optics letters.

[3]  R. Szipöcs,et al.  Ultrabroadband ring oscillator for sub-10-fs pulse generation. , 1996, Optics letters.

[4]  E Gratton,et al.  Fluorescence lifetime imaging by asynchronous pump-probe microscopy. , 1995, Biophysical journal.

[5]  I Gryczynski,et al.  Theory of light quenching: effects of fluorescence polarization, intensity, and anisotropy decays. , 1994, Biophysical journal.

[6]  Joseph R. Lakowicz,et al.  Light Quenching and Fluorescence Depolarization of Rhodamine B and Applications of This Phenomenon to Biophysics. , 1994, The Journal of physical chemistry.

[7]  Colin J. R. Sheppard,et al.  Effects of a Finite-sized Pinhole on 3D Image Formation in Confocal Two-photon Fluorescence Microscopy , 1993 .

[8]  N. Laurendeau,et al.  Pump/probe method for fast analysis of visible spectral signatures utilizing asynchronous optical sampling. , 1987, Applied optics.

[9]  Galen B. King,et al.  Pump/Probe Spectroscopy by Asynchronous Optical Sampling , 1987 .

[10]  Fred E. Lytle,et al.  An Introduction to Time-Resolved Pump/Probe Spectroscopy , 1985 .

[11]  Enrico Gratton,et al.  Spatial resolution in scanning pump-probe fluorescence microscopy , 1997 .

[12]  Richard P. Haugland,et al.  Handbook of fluorescent probes and research chemicals , 1996 .

[13]  Chung-Po Huang,et al.  Sub-10 fs Pulse Generation in Ti:Sapphire: Capabilities and Ultimate Limits , 1994 .

[14]  Colin J. R. Sheppard,et al.  Image formation in two-photon fluorescence microscopy , 1990 .

[15]  R. Hochstrasser,et al.  Biological Processes Studied by Ultrafast Laser Techniques , 1988 .

[16]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[17]  Tony Wilson,et al.  SUPER-RESOLUTION BY CONFOCAL FLUORESCENT MICROSCOPY , 1982 .

[18]  Sidney Udenfriend,et al.  PRINCIPLES OF FLUORESCENCE , 1969 .