Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement.

PURPOSE To evaluate the clinical outcomes of implants placed using different types of computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides, including partially guided and totally guided templates, and determine the accuracy of these guides Materials and methods: In total, 111 implants were placed in 24 patients using CAD/CAM surgical guides. After implant insertion, the positions and angulations of the placed implants relative to those of the planned ones were determined using special software that matched pre- and postoperative computed tomography (CT) images, and deviations were calculated and compared between the different guides and templates. RESULTS The mean angular deviations were 1.72 ± 1.67 and 2.71 ± 2.58, the mean deviations in position at the neck were 0.27 ± 0.24 and 0.69 ± 0.66 mm, the mean deviations in position at the apex were 0.37 ± 0.35 and 0.94 ± 0.75 mm, and the mean depth deviations were 0.32 ± 0.32 and 0.51 ± 0.48 mm with tooth- and mucosa-supported stereolithographic guides, respectively (P < .05 for all). The mean distance deviations when partially guided (29 implants) and totally guided templates (30 implants) were used were 0.54 ± 0.50 mm and 0.89 ± 0.78 mm, respectively, at the neck and 1.10 ± 0.85 mm and 0.81 ± 0.64 mm, respectively, at the apex, with corresponding mean angular deviations of 2.56 ± 2.23° and 2.90 ± 3.0° (P > .05 for all). CONCLUSIONS Tooth-supported surgical guides may be more accurate than mucosa-supported guides, while both partially and totally guided templates can simplify surgery and aid in optimal implant placement.

[1]  M. Cassetta,et al.  Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic surgi-guide. , 2011, International journal of oral and maxillofacial surgery.

[2]  R. Jung,et al.  Consensus statements and recommended clinical procedures regarding computer-assisted implant dentistry. , 2009, The International journal of oral & maxillofacial implants.

[3]  Ersilia Barbato,et al.  Accuracy of two stereolithographic surgical templates: a retrospective study. , 2013, Clinical implant dentistry and related research.

[4]  R Jacobs,et al.  Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. , 2007, Journal of clinical periodontology.

[5]  Ilser Turkyilmaz,et al.  Accuracy of three different types of stereolithographic surgical guide in implant placement: an in vitro study. , 2012, The Journal of prosthetic dentistry.

[6]  André Gahleitner,et al.  Dental CT: imaging technique, anatomy, and pathologic conditions of the jaws , 2003, European Radiology.

[7]  Stephan Eitner,et al.  Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates. , 2007, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[8]  Ilser Turkyilmaz,et al.  Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants. , 2008, Journal of periodontology.

[9]  Filip Schutyser,et al.  An Accuracy Study of Computer-Planned Implant Placement in the Augmented Maxilla Using Mucosa-Supported Surgical Templates. , 2015, Clinical implant dentistry and related research.

[10]  Kunal Lal,et al.  Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part II. A clinical report. , 2006, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[11]  Volkan Arısan,et al.  Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study. , 2010, Journal of periodontology.

[12]  Jacob Rosen,et al.  Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study. , 2009, The Journal of prosthetic dentistry.

[13]  R Jacobs,et al.  Accuracy of computer-aided implant placement. , 2012, Clinical oral implants research.

[14]  S. Rosenstiel,et al.  Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. , 2009, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[15]  M. Cassetta,et al.  The intrinsic error of a stereolithographic surgical template in implant guided surgery. , 2013, International journal of oral and maxillofacial surgery.

[16]  Kunal Lal,et al.  Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. The concept. , 2006, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[17]  G. Schiroli,et al.  Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. , 2009, The International journal of oral & maxillofacial implants.

[18]  D. Buser,et al.  A retrospective analysis of patients referred for implant placement to a specialty clinic: indications, surgical procedures, and early failures. , 2008, The International journal of oral & maxillofacial implants.

[19]  Bruno Salles Sotto-Maior,et al.  Clinical accuracy of flapless computer-guided surgery for implant placement in edentulous arches. , 2013, The International journal of oral & maxillofacial implants.

[20]  G. Mandelaris,et al.  Computer-guided implant dentistry for precise implant placement: combining specialized stereolithographically generated drilling guides and surgical implant instrumentation. , 2010, The International journal of periodontics & restorative dentistry.

[21]  J. D'haese,et al.  Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature. , 2012, Clinical implant dentistry and related research.