Thermal properties optimization of envelope in energy-saving renovation of existing public buildings

Abstract The shape factor and windows-to-wall ratio are different from building to building. How to design the thermal properties of building envelope affects energy-saving renovation economy of existing public buildings. The limited heat consumption per unit volume and equivalent heat transfer coefficient of external windows and wall were proposed based on the prescription of China national standard “Design standard for energy efficiency of public buildings”(GB50189-2005) for envelope design. Mathematical model on economical thermal insulation thickness of building envelope and thermal properties optimizing of envelope were built considering the impact of house orientation, windows-to-wall ratio and types of windows. The model is verified to be feasible by an existing public building in Shenyang. The variation of windows-to-wall ratio for different orientation leads to the different economical thermal insulation thickness of building envelope and payback period. The project optimization design for envelope renovation could be determined by the technical and economic analysis considering the impact of house orientation, windows-to-wall ratio, types of insulation materials and windows.

[1]  Tan Da-lu Discussion on optimal thermal insulation thickness of energy saving building external wall andbenefit assessment , 2007 .

[2]  İbrahim Çakmanus,et al.  Renovation of existing office buildings in regard to energy economy: An example from Ankara, Turkey , 2007 .

[3]  M. F. Zedan,et al.  Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer model , 2005 .

[4]  Ray Galvin,et al.  Thermal upgrades of existing homes in Germany: The building code, subsidies, and economic efficiency , 2010 .

[5]  Teuku Meurah Indra Mahlia,et al.  Cost benefits analysis and emission reductions of optimum thickness and air gaps for selected insulation materials for building walls in Maldives , 2010 .

[6]  Derya Burcu Özkan,et al.  Optimization of insulation thickness for different glazing areas in buildings for various climatic regions in Turkey , 2011 .

[7]  Cao Hai-xia Coal Prices Reform Course and Future Development Trend in China , 2008 .

[8]  O. Kaynakli,et al.  A study on residential heating energy requirement and optimum insulation thickness , 2008 .

[9]  Hua Hong Newly Development of Building Saving-energy and Its Technology Abroad , 2006 .

[10]  Wu Wei-wei Optimizing insulation thickness of external walls for residential buildings , 2008 .

[11]  Ali Bolatturk,et al.  Determination of optimum insulation thickness for building walls with respect to various fuels and climate zones in Turkey , 2006 .

[12]  Janusz Adamczyk,et al.  Economic and environmental benefits of thermal insulation of building external walls , 2011 .

[13]  Emin Kahya,et al.  Determination of optimum insulation thicknesses of the external walls and roof (ceiling) for Turkey's different degree-day regions , 2007 .

[14]  He Lu-hua Energy Saving Reconstruction of Existing Office Buildings , 2009 .

[15]  Haji Hassan Masjuki,et al.  CORRELATION BETWEEN THERMAL CONDUCTIVITY AND THE THICKNESS OF SELECTED INSULATION MATERIALS FOR BUILDING WALL , 2007 .

[16]  Naouel Daouas,et al.  A study on optimum insulation thickness in walls and energy savings in Tunisian buildings based on analytical calculation of cooling and heating transmission loads , 2011 .

[17]  M. S Söylemez,et al.  Optimum insulation thickness for refrigeration applications , 1999 .

[18]  Zhan Zhao-xi Economic Evaluation on Energy-saving Retrofit for Existing Buildings Based on Energy Consumption Analysis , 2010 .

[19]  Li Di Analysis of Technical and Economic Effects for Energy Efficiency Reconstruction of Existing Office Buildings , 2009 .

[20]  U.Teoman Aksoy,et al.  A study on the optimum insulation thicknesses of various types of external walls with respect to different materials, fuels and climate zones in Turkey , 2012 .

[21]  Meral Ozel,et al.  Thermal performance and optimum insulation thickness of building walls with different structure materials , 2011 .

[22]  Kazunori Hokao,et al.  Economic analysis of energy-saving renovation measures for urban existing residential buildings in China based on thermal simulation and site investigation , 2009 .

[23]  Aynur Ucar,et al.  Thermoeconomic analysis method for optimization of insulation thickness for the four different climatic regions of Turkey , 2010 .

[24]  Meral Ozel,et al.  The influence of exterior surface solar absorptivity on thermal characteristics and optimum insulation thickness , 2012 .

[25]  Figen Balo,et al.  Effect of fuel type on the optimum thickness of selected insulation materials for the four different climatic regions of Turkey , 2009 .

[26]  Panyu Zhu,et al.  The optimum thickness and energy saving potential of external wall insulation in different climate zones of China , 2011 .

[27]  Xu Hong-sheng Simulation Analysis on the Retrofitted Energy Efficiency of an Existing Office Building , 2009 .

[28]  Ali Bolatturk,et al.  Optimum insulation thicknesses for building walls with respect to cooling and heating degree-hours in the warmest zone of Turkey , 2008 .

[29]  Qian Xia Analysis of Energy-saving Transformation Measures and Effect of Large-scale Public Buildings , 2009 .

[30]  Guo Nan Energy-saving Insulation Wall Thickness of the Existing Building in Changchun , 2010 .

[31]  Liwei Tian,et al.  A study on optimum insulation thicknesses of external walls in hot summer and cold winter zone of China , 2009 .

[32]  Zhao Jian-ping Study on Energy-saving Technology and Design Optimization of Facade Retrofit Project of Existing Building in Cold and Severe Cold Area , 2008 .

[33]  Naouel Daouas,et al.  Analytical periodic solution for the study of thermal performance and optimum insulation thickness of building walls in Tunisia , 2010 .

[34]  Cheonghoon Baek,et al.  Policy measures to overcome barriers to energy renovation of existing buildings , 2012 .

[35]  Ö. Altan Dombaycı,et al.  Optimization of insulation thickness for external walls using different energy-sources , 2004 .

[36]  Figen Balo,et al.  DETERMINATION OF THE ENERGY SAVINGS AND THE OPTIMUM INSULATION THICKNESS IN THE FOUR DIFFERENT INSULATED EXTERIOR WALLS , 2010 .

[37]  Ramazan Köse,et al.  Thermoeconomic optimization of insulation thickness considering condensed vapor in buildings , 2006 .

[38]  Li Chun-li Research on Key Factors of Implement for Energy-saving Reconstruction on Wall of Existing Heating Building , 2007 .

[39]  Kevser Dincer,et al.  Modelling of a thermal insulation system based on the coldest temperature conditions by using artificial neural networks to determine performance of building for wall types in Turkey , 2011 .

[40]  Mohammed Al-Khawaja,et al.  Determination and selecting the optimum thickness of insulation for buildings in hot countries by accounting for solar radiation , 2004 .

[41]  Meral Ozel,et al.  Effect of wall orientation on the optimum insulation thickness by using a dynamic method , 2011 .

[42]  Omer Kaynakli,et al.  A review of the economical and optimum thermal insulation thickness for building applications , 2012 .

[43]  Liwei Tian,et al.  Optimum insulation thickness of residential roof with respect to solar-air degree-hours in hot summe , 2011 .