The Applications of Finite Element Analysis in Proximal Humeral Fractures
暂无分享,去创建一个
Wei You | Kang Chen | Jiaming Cui | Weimin Zhu | Daping Wang | Yongyu Ye | Daping Wang | Jiaming Cui | Kang‐wu Chen | Weimin Zhu | Wei You | Y. Ye
[1] T. Lugli. Artificial shoulder joint by Péan (1893): the facts of an exceptional intervention and the prosthetic method. , 1978, Clinical orthopaedics and related research.
[2] J. Gorczyca,et al. Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. , 2008, The Journal of bone and joint surgery. American volume.
[3] P. Büchler,et al. Benefits of an anatomical reconstruction of the humeral head during shoulder arthroplasty: a finite element analysis. , 2004, Clinical biomechanics.
[4] W. Brekelmans,et al. A new method to analyse the mechanical behaviour of skeletal parts. , 1972, Acta orthopaedica Scandinavica.
[5] F. Gebhard,et al. Mechanical assessment of local bone quality to predict failure of locked plating in a proximal humerus fracture model. , 2013, Orthopedics.
[6] Zhi-Jun Wang,et al. A Three-Dimensional Finite Element Model for Biomechanical Analysis of the Hip , 2013, Cell Biochemistry and Biophysics.
[7] D. Ring,et al. Does the timing of surgery for proximal humeral fracture affect inpatient outcomes? , 2014, Journal of shoulder and elbow surgery.
[8] J. Wunder,et al. The biomechanical effect of torsion on humeral shaft repair techniques for completed pathological fractures. , 2012, Journal of biomechanical engineering.
[9] M. Heller,et al. Straining of the intact and fractured proximal humerus under physiological-like loading. , 2003, Journal of biomechanics.
[10] G. Harris,et al. Mechanical characterization of fourth generation composite humerus , 2011, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[11] J. Kodvanj,et al. Comparative study of three models of extra-articular distal humerus fracture osteosynthesis using the finite element method on an osteoporotic computational model. , 2013, Injury.
[12] A. Nana,et al. Dual Plating of Humeral Shaft Fractures: Orthogonal Plates Biomechanically Outperform Side-by-Side Plates , 2014, Clinical orthopaedics and related research.
[13] R G Richards,et al. Stress-shielding induced bone remodeling in cementless shoulder resurfacing arthroplasty: a finite element analysis and in vivo results. , 2014, Journal of biomechanics.
[14] D. Ring,et al. The factors influencing the decision making of operative treatment for proximal humeral fractures. , 2015, Journal of shoulder and elbow surgery.
[15] P. Mcnair,et al. Changing incidence and residual lifetime risk of common osteoporosis-related fractures , 1993, Osteoporosis International.
[16] P. McHugh,et al. Calibration of a constitutive model for the post-yield behaviour of cortical bone. , 2009, Journal of the mechanical behavior of biomedical materials.
[17] L. Munuera,et al. Proximal humerus fracture rotational stability after fixation using a locking plate or a fixed-angle locked nail: the role of implant stiffness. , 2010, Clinical biomechanics.
[18] P. Kannus,et al. Update in the Epidemiology of Proximal Humeral Fractures , 2006, Clinical orthopaedics and related research.
[19] T. Maluta,et al. The treatment of proximal humeral fractures with a "Polarus" intramedullary nail. , 2014, Acta bio-medica : Atenei Parmensis.
[20] H. Mullett,et al. Locking plate fixation for proximal humerus fractures. , 2012, Orthopedics.
[21] M. Leunig,et al. Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus. , 2004, Journal of shoulder and elbow surgery.
[22] C. Ahmad,et al. Reverse Shoulder Arthroplasty for the Management of Proximal Humerus Fractures , 2015, The Journal of the American Academy of Orthopaedic Surgeons.
[23] K J Mathias,et al. Design of a retractable intramedullary nail for the humerus. , 2003, Bio-medical materials and engineering.
[24] M. Kääb,et al. Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study. , 2009, The Journal of bone and joint surgery. American volume.
[25] Gábor Székely,et al. Computer assisted reconstruction of complex proximal humerus fractures for preoperative planning , 2012, Medical Image Anal..
[26] Marco Viceconti,et al. An improved method for the automatic mapping of computed tomography numbers onto finite element models. , 2004, Medical engineering & physics.
[27] R. Gupta,et al. Two-Part Surgical Neck Fractures of the Proximal Part of the Humerus: A Biomechanical Evaluation of Two Fixation Techniques , 2008 .
[28] J. McGarry,et al. Experimental and Numerical Characterisation of the Elasto-Plastic Properties of Bovine Trabecular Bone and a Trabecular Bone Analogue Abstract , 2019 .
[29] Michael J Gardner,et al. The Importance of Medial Support in Locked Plating of Proximal Humerus Fractures , 2007, Journal of orthopaedic trauma.
[30] C. Ahmad,et al. Hemiarthroplasty for Three‐ and Four‐part Proximal Humerus Fractures , 2012, The Journal of the American Academy of Orthopaedic Surgeons.
[31] H. Mullett,et al. Locking Plate Fixation with and without Inferomedial Screws for Proximal Humeral Fractures: A Biomechanical Study , 2014, Journal of orthopaedic surgery.
[32] R. L. Dooley,et al. Finite element modeling of the glenoid component: Effect of design parameters on stress distribution. , 1992, Journal of shoulder and elbow surgery.
[33] C. Court-Brown,et al. The impacted varus (A2.2) proximal humeral fracture Prediction of outcome and results of nonoperative treatment in 99 patients , 2004, Acta orthopaedica Scandinavica.
[34] J. Krier,et al. Finite element analysis of the strain distribution in the humeral head tubercles during abduction: comparison of young and osteoporotic bone , 2006, Surgical and Radiologic Anatomy.
[35] C. Neer. Articular replacement for the humeral head. , 1955, The Journal of bone and joint surgery. American volume.
[36] P. McGarry,et al. Effect of Calcium Triphosphate Cement on Proximal Humeral Fracture Osteosynthesis: A Finite Element Analysis , 2013, Journal of orthopaedic surgery.
[37] J. Zuckerman,et al. Fracture site augmentation with calcium phosphate cement reduces screw penetration after open reduction-internal fixation of proximal humeral fractures. , 2012, Journal of shoulder and elbow surgery.
[38] Scott L Delp,et al. 3D finite element models of shoulder muscles for computing lines of actions and moment arms , 2014, Computer methods in biomechanics and biomedical engineering.
[39] R. Müller,et al. The discrete nature of trabecular bone microarchitecture affects implant stability. , 2012, Journal of biomechanics.
[40] C. Neer,et al. Displaced proximal humeral fractures. Part I. Classification and evaluation. By Charles S. Neer, I, 1970. , 1970, Clinical orthopaedics and related research.
[41] Mitroi Eduard,et al. A Novel Implant Regarding Transcondylar Humeral Fractures Stabilization. A Comparative Study of Two Approaches , 2014 .
[42] Ulrich Dieter,et al. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled? , 2003, Injury.
[43] L. Prantl,et al. Proximal humerus fractures: a comparative biomechanical analysis of intra and extramedullary implants , 2007, Archives of Orthopaedic and Trauma Surgery.
[44] M. Harris,et al. Factors associated with the decision for operative versus non-operative treatment of displaced proximal humerus fractures in the elderly. , 2013, Injury.
[45] N. Clement,et al. The outcome of proximal humeral fractures in the elderly: predictors of mortality and function. , 2014, The bone & joint journal.
[46] Daniel Baumgartner,et al. Refixation stability in shoulder hemiarthroplasty in case of four-part proximal humeral fracture , 2009, Medical & Biological Engineering & Computing.
[47] R. Zdero,et al. The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support. , 2010, The Journal of trauma.
[48] Li Ma,et al. Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: a finite element analysis. , 2015, Acta orthopaedica et traumatologica turcica.
[49] C. Neer. Displaced proximal humeral fractures , 2007 .
[50] J. Kruczyński,et al. Radiological and biomechanical analysis of humeral fractures occurring during arm wrestling , 2012, Medical science monitor : international medical journal of experimental and clinical research.
[51] H. Hagino,et al. Changing incidence of hip, distal radius, and proximal humerus fractures in Tottori Prefecture, Japan. , 1999, Bone.
[52] P. McGarry,et al. Investigation of metallic and carbon fibre PEEK fracture fixation devices for three-part proximal humeral fractures. , 2013, Medical engineering & physics.
[53] P. Kannus,et al. Rate of proximal humeral fractures in older Finnish women between 1970 and 2007. , 2009, Bone.
[54] P. Braidotti,et al. Tensile experiments and SEM fractography on bovine subchondral bone. , 2000, Journal of biomechanics.
[55] J. Macy. Open Reduction and Internal Fixation of Proximal Humerus Fractures Using a Proximal Humeral Locked Plate: A Prospective Multicenter Analysis , 2010 .
[56] C. Neer,et al. Displaced proximal humeral fractures. I. Classification and evaluation. , 1970, The Journal of bone and joint surgery. American volume.
[57] José Benito Bouza-Rodríguez,et al. Three-Dimensional Biomechanical Analysis of the Bovine Humerus , 2014 .
[58] M. Kuster,et al. Second generation locked plating of proximal humerus fractures—A prospective multicentre observational study , 2011, International Orthopaedics.
[59] Xiu-hui Wang,et al. Computerized Virtual Surgery Planning for ORIF of Proximal Humeral Fractures. , 2015, Orthopedics.
[60] S. Rothstock,et al. Biomechanical evaluation of two intramedullary nailing techniques with different locking options in a three-part fracture proximal humerus model. , 2012, Clinical biomechanics.
[61] I. Tamimi,et al. Displaced proximal humeral fractures: when is surgery necessary? , 2015, Injury.
[62] Stephen J Ferguson,et al. A new prosthetic design for proximal humeral fractures: reconstructing the glenohumeral unit. , 2004, Journal of shoulder and elbow surgery.
[63] A. Prescher,et al. L-F1.2 Biomechanical evaluation of locking plate fixation of proximal humeral fractures augmented with calcium phosphate cement , 2012 .
[64] Levent Eralp,et al. Prognostic factors in prosthetic replacement for acute proximal humerus fractures. , 2003, Journal of orthopaedic trauma.
[65] Guido La Rosa,et al. Evaluation and improvement of the efficiency of the Seidel humeral nail by numerical-experimental analysis of the bone-implant contact. , 2006, Medical engineering & physics.
[66] P. Boileau,et al. Epidemiology of proximal humerus fractures managed in a trauma center. , 2012, Orthopaedics & traumatology, surgery & research : OTSR.
[67] S. Cummings,et al. Which Fractures Are Associated with Low Appendicular Bone Mass in Elderly Women , 1991 .
[68] K. Dietz,et al. Complication rates and outcomes stratified by treatment modalities in proximal humeral fractures: a systematic literature review from 1970–2009 , 2013, Patient Safety in Surgery.
[69] F. Gebhard,et al. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures. , 2013, Injury.
[70] J. Goldhahn,et al. The Influence of Local Bone Density on the Outcome of One Hundred and Fifty Proximal Humeral Fractures Treated with a Locking Plate. , 2014, The Journal of bone and joint surgery. American volume.
[71] T. Pressel,et al. Bone remodelling in humeral arthroplasty: follow-up using CT imaging and finite element modeling – an in vivo case study , 2000, Archives of Orthopaedic and Trauma Surgery.
[72] P. Moonot,et al. Early results for treatment of three- and four-part fractures of the proximal humerus using the PHILOS plate system. , 2007, The Journal of bone and joint surgery. British volume.
[73] Neil Ashwood,et al. Polarus Nail Fixation for Proximal Humeral Fractures , 2014, Journal of orthopaedic surgery.
[74] J. Warner,et al. Treatment choice affects inpatient adverse events and mortality in older aged inpatients with an isolated fracture of the proximal humerus. , 2014, Journal of shoulder and elbow surgery.
[75] Hongjun Kang,et al. Meta-analysis of locking plate versus intramedullary nail for treatment of proximal humeral fractures , 2015, Journal of Orthopaedic Surgery and Research.
[76] P. Ray,et al. Fixation of proximal humeral fractures with the Polarus nail. , 2001, Journal of shoulder and elbow surgery.
[77] C. Court-Brown,et al. Impacted valgus fractures (B1.1) of the proximal humerus. The results of non-operative treatment. , 2002, The Journal of bone and joint surgery. British volume.
[78] A. Pavić,et al. The Results of Internal Fixation of Proximal Humeral Osteoporotic Fractures with PHILOS Locking Plate. , 2014, Psychiatria Danubina.
[79] T. M. Nejad,et al. Finite element modelling of cornea mechanics: a review. , 2014, Arquivos brasileiros de oftalmologia.
[80] A. Desai,et al. Management of proximal humerus fractures in adults. , 2014, World journal of orthopedics.
[81] G. H. van Lenthe,et al. Augmentation of peri‐implant bone improves implant stability: Quantification using simulated bone loss , 2012, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[82] H. Mullett,et al. Effect of Calcium Triphosphate Cement on Proximal Humeral Fracture Osteosynthesis: A Cadaveric Biomechanical Study , 2013, Journal of orthopaedic surgery.
[83] A. Nana,et al. Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study. , 2015, Technology and health care : official journal of the European Society for Engineering and Medicine.
[84] T. Lind,et al. The epidemiology of fractures of the proximal humerus , 2004, Archives of Orthopaedic and Trauma Surgery.
[85] V. Lepola,et al. Epidemiology of proximal humerus fractures , 2015, Archives of Osteoporosis.
[86] M. Gardner,et al. Proximal humerus fractures , 1999, Current Reviews in Musculoskeletal Medicine.
[87] P. Arbenz,et al. Implant stability is affected by local bone microstructural quality. , 2011, Bone.
[88] Dongsheng Zhou,et al. Application of Additional Medial Plate in Treatment of Proximal Humeral Fractures With Unstable Medial Column , 2015, Medicine.
[89] A. Nicol,et al. Re-attachment of the tuberosities of the humerus following hemiarthroplasty for four-part fracture. , 2006, The Journal of bone and joint surgery. British volume.
[90] T. H.,et al. The Journal of Bone and Joint Surgery , 2006 .
[91] N Maffulli,et al. Complex proximal humeral fractures in adults--a systematic review of management. , 2001, Injury.
[92] M. Karagas,et al. The epidemiology of peripheral fractures. , 1996, Bone.
[93] M. Blauth,et al. The effect of in situ augmentation on implant anchorage in proximal humeral head fractures. , 2012, Injury.
[94] T. Mittlmeier,et al. Locking plate fixation of humeral head fractures with a telescoping screw. A comparative biomechanical study versus a standard plate. , 2012, Injury.
[95] C. Bono,et al. Effect of displacement of fractures of the greater tuberosity on the mechanics of the shoulder. , 2001, The Journal of bone and joint surgery. British volume.
[96] C. Olsson,et al. Increased fragility in patients with fracture of the proximal humerus: a case control study. , 2004, Bone.
[97] P. Varga,et al. Implicit modeling of screw threads for efficient finite element analysis of complex bone-implant systems. , 2016, Journal of biomechanics.