The Applications of Finite Element Analysis in Proximal Humeral Fractures

Proximal humeral fractures are common and most challenging, due to the complexity of the glenohumeral joint, especially in the geriatric population with impacted fractures, that the development of implants continues because currently the problems with their fixation are not solved. Pre-, intra-, and postoperative assessments are crucial in management of those patients. Finite element analysis, as one of the valuable tools, has been implemented as an effective and noninvasive method to analyze proximal humeral fractures, providing solid evidence for management of troublesome patients. However, no review article about the applications and effects of finite element analysis in assessing proximal humeral fractures has been reported yet. This review article summarized the applications, contribution, and clinical significance of finite element analysis in assessing proximal humeral fractures. Furthermore, the limitations of finite element analysis, the difficulties of more realistic simulation, and the validation and also the creation of validated FE models were discussed. We concluded that although some advancements in proximal humeral fractures researches have been made by using finite element analysis, utility of this powerful tool for routine clinical management and adequate simulation requires more state-of-the-art studies to provide evidence and bases.

[1]  T. Lugli Artificial shoulder joint by Péan (1893): the facts of an exceptional intervention and the prosthetic method. , 1978, Clinical orthopaedics and related research.

[2]  J. Gorczyca,et al.  Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. , 2008, The Journal of bone and joint surgery. American volume.

[3]  P. Büchler,et al.  Benefits of an anatomical reconstruction of the humeral head during shoulder arthroplasty: a finite element analysis. , 2004, Clinical biomechanics.

[4]  W. Brekelmans,et al.  A new method to analyse the mechanical behaviour of skeletal parts. , 1972, Acta orthopaedica Scandinavica.

[5]  F. Gebhard,et al.  Mechanical assessment of local bone quality to predict failure of locked plating in a proximal humerus fracture model. , 2013, Orthopedics.

[6]  Zhi-Jun Wang,et al.  A Three-Dimensional Finite Element Model for Biomechanical Analysis of the Hip , 2013, Cell Biochemistry and Biophysics.

[7]  D. Ring,et al.  Does the timing of surgery for proximal humeral fracture affect inpatient outcomes? , 2014, Journal of shoulder and elbow surgery.

[8]  J. Wunder,et al.  The biomechanical effect of torsion on humeral shaft repair techniques for completed pathological fractures. , 2012, Journal of biomechanical engineering.

[9]  M. Heller,et al.  Straining of the intact and fractured proximal humerus under physiological-like loading. , 2003, Journal of biomechanics.

[10]  G. Harris,et al.  Mechanical characterization of fourth generation composite humerus , 2011, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[11]  J. Kodvanj,et al.  Comparative study of three models of extra-articular distal humerus fracture osteosynthesis using the finite element method on an osteoporotic computational model. , 2013, Injury.

[12]  A. Nana,et al.  Dual Plating of Humeral Shaft Fractures: Orthogonal Plates Biomechanically Outperform Side-by-Side Plates , 2014, Clinical orthopaedics and related research.

[13]  R G Richards,et al.  Stress-shielding induced bone remodeling in cementless shoulder resurfacing arthroplasty: a finite element analysis and in vivo results. , 2014, Journal of biomechanics.

[14]  D. Ring,et al.  The factors influencing the decision making of operative treatment for proximal humeral fractures. , 2015, Journal of shoulder and elbow surgery.

[15]  P. Mcnair,et al.  Changing incidence and residual lifetime risk of common osteoporosis-related fractures , 1993, Osteoporosis International.

[16]  P. McHugh,et al.  Calibration of a constitutive model for the post-yield behaviour of cortical bone. , 2009, Journal of the mechanical behavior of biomedical materials.

[17]  L. Munuera,et al.  Proximal humerus fracture rotational stability after fixation using a locking plate or a fixed-angle locked nail: the role of implant stiffness. , 2010, Clinical biomechanics.

[18]  P. Kannus,et al.  Update in the Epidemiology of Proximal Humeral Fractures , 2006, Clinical orthopaedics and related research.

[19]  T. Maluta,et al.  The treatment of proximal humeral fractures with a "Polarus" intramedullary nail. , 2014, Acta bio-medica : Atenei Parmensis.

[20]  H. Mullett,et al.  Locking plate fixation for proximal humerus fractures. , 2012, Orthopedics.

[21]  M. Leunig,et al.  Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus. , 2004, Journal of shoulder and elbow surgery.

[22]  C. Ahmad,et al.  Reverse Shoulder Arthroplasty for the Management of Proximal Humerus Fractures , 2015, The Journal of the American Academy of Orthopaedic Surgeons.

[23]  K J Mathias,et al.  Design of a retractable intramedullary nail for the humerus. , 2003, Bio-medical materials and engineering.

[24]  M. Kääb,et al.  Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study. , 2009, The Journal of bone and joint surgery. American volume.

[25]  Gábor Székely,et al.  Computer assisted reconstruction of complex proximal humerus fractures for preoperative planning , 2012, Medical Image Anal..

[26]  Marco Viceconti,et al.  An improved method for the automatic mapping of computed tomography numbers onto finite element models. , 2004, Medical engineering & physics.

[27]  R. Gupta,et al.  Two-Part Surgical Neck Fractures of the Proximal Part of the Humerus: A Biomechanical Evaluation of Two Fixation Techniques , 2008 .

[28]  J. McGarry,et al.  Experimental and Numerical Characterisation of the Elasto-Plastic Properties of Bovine Trabecular Bone and a Trabecular Bone Analogue Abstract , 2019 .

[29]  Michael J Gardner,et al.  The Importance of Medial Support in Locked Plating of Proximal Humerus Fractures , 2007, Journal of orthopaedic trauma.

[30]  C. Ahmad,et al.  Hemiarthroplasty for Three‐ and Four‐part Proximal Humerus Fractures , 2012, The Journal of the American Academy of Orthopaedic Surgeons.

[31]  H. Mullett,et al.  Locking Plate Fixation with and without Inferomedial Screws for Proximal Humeral Fractures: A Biomechanical Study , 2014, Journal of orthopaedic surgery.

[32]  R. L. Dooley,et al.  Finite element modeling of the glenoid component: Effect of design parameters on stress distribution. , 1992, Journal of shoulder and elbow surgery.

[33]  C. Court-Brown,et al.  The impacted varus (A2.2) proximal humeral fracture Prediction of outcome and results of nonoperative treatment in 99 patients , 2004, Acta orthopaedica Scandinavica.

[34]  J. Krier,et al.  Finite element analysis of the strain distribution in the humeral head tubercles during abduction: comparison of young and osteoporotic bone , 2006, Surgical and Radiologic Anatomy.

[35]  C. Neer Articular replacement for the humeral head. , 1955, The Journal of bone and joint surgery. American volume.

[36]  P. McGarry,et al.  Effect of Calcium Triphosphate Cement on Proximal Humeral Fracture Osteosynthesis: A Finite Element Analysis , 2013, Journal of orthopaedic surgery.

[37]  J. Zuckerman,et al.  Fracture site augmentation with calcium phosphate cement reduces screw penetration after open reduction-internal fixation of proximal humeral fractures. , 2012, Journal of shoulder and elbow surgery.

[38]  Scott L Delp,et al.  3D finite element models of shoulder muscles for computing lines of actions and moment arms , 2014, Computer methods in biomechanics and biomedical engineering.

[39]  R. Müller,et al.  The discrete nature of trabecular bone microarchitecture affects implant stability. , 2012, Journal of biomechanics.

[40]  C. Neer,et al.  Displaced proximal humeral fractures. Part I. Classification and evaluation. By Charles S. Neer, I, 1970. , 1970, Clinical orthopaedics and related research.

[41]  Mitroi Eduard,et al.  A Novel Implant Regarding Transcondylar Humeral Fractures Stabilization. A Comparative Study of Two Approaches , 2014 .

[42]  Ulrich Dieter,et al.  Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled? , 2003, Injury.

[43]  L. Prantl,et al.  Proximal humerus fractures: a comparative biomechanical analysis of intra and extramedullary implants , 2007, Archives of Orthopaedic and Trauma Surgery.

[44]  M. Harris,et al.  Factors associated with the decision for operative versus non-operative treatment of displaced proximal humerus fractures in the elderly. , 2013, Injury.

[45]  N. Clement,et al.  The outcome of proximal humeral fractures in the elderly: predictors of mortality and function. , 2014, The bone & joint journal.

[46]  Daniel Baumgartner,et al.  Refixation stability in shoulder hemiarthroplasty in case of four-part proximal humeral fracture , 2009, Medical & Biological Engineering & Computing.

[47]  R. Zdero,et al.  The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support. , 2010, The Journal of trauma.

[48]  Li Ma,et al.  Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: a finite element analysis. , 2015, Acta orthopaedica et traumatologica turcica.

[49]  C. Neer Displaced proximal humeral fractures , 2007 .

[50]  J. Kruczyński,et al.  Radiological and biomechanical analysis of humeral fractures occurring during arm wrestling , 2012, Medical science monitor : international medical journal of experimental and clinical research.

[51]  H. Hagino,et al.  Changing incidence of hip, distal radius, and proximal humerus fractures in Tottori Prefecture, Japan. , 1999, Bone.

[52]  P. McGarry,et al.  Investigation of metallic and carbon fibre PEEK fracture fixation devices for three-part proximal humeral fractures. , 2013, Medical engineering & physics.

[53]  P. Kannus,et al.  Rate of proximal humeral fractures in older Finnish women between 1970 and 2007. , 2009, Bone.

[54]  P. Braidotti,et al.  Tensile experiments and SEM fractography on bovine subchondral bone. , 2000, Journal of biomechanics.

[55]  J. Macy Open Reduction and Internal Fixation of Proximal Humerus Fractures Using a Proximal Humeral Locked Plate: A Prospective Multicenter Analysis , 2010 .

[56]  C. Neer,et al.  Displaced proximal humeral fractures. I. Classification and evaluation. , 1970, The Journal of bone and joint surgery. American volume.

[57]  José Benito Bouza-Rodríguez,et al.  Three-Dimensional Biomechanical Analysis of the Bovine Humerus , 2014 .

[58]  M. Kuster,et al.  Second generation locked plating of proximal humerus fractures—A prospective multicentre observational study , 2011, International Orthopaedics.

[59]  Xiu-hui Wang,et al.  Computerized Virtual Surgery Planning for ORIF of Proximal Humeral Fractures. , 2015, Orthopedics.

[60]  S. Rothstock,et al.  Biomechanical evaluation of two intramedullary nailing techniques with different locking options in a three-part fracture proximal humerus model. , 2012, Clinical biomechanics.

[61]  I. Tamimi,et al.  Displaced proximal humeral fractures: when is surgery necessary? , 2015, Injury.

[62]  Stephen J Ferguson,et al.  A new prosthetic design for proximal humeral fractures: reconstructing the glenohumeral unit. , 2004, Journal of shoulder and elbow surgery.

[63]  A. Prescher,et al.  L-F1.2 Biomechanical evaluation of locking plate fixation of proximal humeral fractures augmented with calcium phosphate cement , 2012 .

[64]  Levent Eralp,et al.  Prognostic factors in prosthetic replacement for acute proximal humerus fractures. , 2003, Journal of orthopaedic trauma.

[65]  Guido La Rosa,et al.  Evaluation and improvement of the efficiency of the Seidel humeral nail by numerical-experimental analysis of the bone-implant contact. , 2006, Medical engineering & physics.

[66]  P. Boileau,et al.  Epidemiology of proximal humerus fractures managed in a trauma center. , 2012, Orthopaedics & traumatology, surgery & research : OTSR.

[67]  S. Cummings,et al.  Which Fractures Are Associated with Low Appendicular Bone Mass in Elderly Women , 1991 .

[68]  K. Dietz,et al.  Complication rates and outcomes stratified by treatment modalities in proximal humeral fractures: a systematic literature review from 1970–2009 , 2013, Patient Safety in Surgery.

[69]  F. Gebhard,et al.  Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures. , 2013, Injury.

[70]  J. Goldhahn,et al.  The Influence of Local Bone Density on the Outcome of One Hundred and Fifty Proximal Humeral Fractures Treated with a Locking Plate. , 2014, The Journal of bone and joint surgery. American volume.

[71]  T. Pressel,et al.  Bone remodelling in humeral arthroplasty: follow-up using CT imaging and finite element modeling – an in vivo case study , 2000, Archives of Orthopaedic and Trauma Surgery.

[72]  P. Moonot,et al.  Early results for treatment of three- and four-part fractures of the proximal humerus using the PHILOS plate system. , 2007, The Journal of bone and joint surgery. British volume.

[73]  Neil Ashwood,et al.  Polarus Nail Fixation for Proximal Humeral Fractures , 2014, Journal of orthopaedic surgery.

[74]  J. Warner,et al.  Treatment choice affects inpatient adverse events and mortality in older aged inpatients with an isolated fracture of the proximal humerus. , 2014, Journal of shoulder and elbow surgery.

[75]  Hongjun Kang,et al.  Meta-analysis of locking plate versus intramedullary nail for treatment of proximal humeral fractures , 2015, Journal of Orthopaedic Surgery and Research.

[76]  P. Ray,et al.  Fixation of proximal humeral fractures with the Polarus nail. , 2001, Journal of shoulder and elbow surgery.

[77]  C. Court-Brown,et al.  Impacted valgus fractures (B1.1) of the proximal humerus. The results of non-operative treatment. , 2002, The Journal of bone and joint surgery. British volume.

[78]  A. Pavić,et al.  The Results of Internal Fixation of Proximal Humeral Osteoporotic Fractures with PHILOS Locking Plate. , 2014, Psychiatria Danubina.

[79]  T. M. Nejad,et al.  Finite element modelling of cornea mechanics: a review. , 2014, Arquivos brasileiros de oftalmologia.

[80]  A. Desai,et al.  Management of proximal humerus fractures in adults. , 2014, World journal of orthopedics.

[81]  G. H. van Lenthe,et al.  Augmentation of peri‐implant bone improves implant stability: Quantification using simulated bone loss , 2012, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[82]  H. Mullett,et al.  Effect of Calcium Triphosphate Cement on Proximal Humeral Fracture Osteosynthesis: A Cadaveric Biomechanical Study , 2013, Journal of orthopaedic surgery.

[83]  A. Nana,et al.  Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study. , 2015, Technology and health care : official journal of the European Society for Engineering and Medicine.

[84]  T. Lind,et al.  The epidemiology of fractures of the proximal humerus , 2004, Archives of Orthopaedic and Trauma Surgery.

[85]  V. Lepola,et al.  Epidemiology of proximal humerus fractures , 2015, Archives of Osteoporosis.

[86]  M. Gardner,et al.  Proximal humerus fractures , 1999, Current Reviews in Musculoskeletal Medicine.

[87]  P. Arbenz,et al.  Implant stability is affected by local bone microstructural quality. , 2011, Bone.

[88]  Dongsheng Zhou,et al.  Application of Additional Medial Plate in Treatment of Proximal Humeral Fractures With Unstable Medial Column , 2015, Medicine.

[89]  A. Nicol,et al.  Re-attachment of the tuberosities of the humerus following hemiarthroplasty for four-part fracture. , 2006, The Journal of bone and joint surgery. British volume.

[90]  T. H.,et al.  The Journal of Bone and Joint Surgery , 2006 .

[91]  N Maffulli,et al.  Complex proximal humeral fractures in adults--a systematic review of management. , 2001, Injury.

[92]  M. Karagas,et al.  The epidemiology of peripheral fractures. , 1996, Bone.

[93]  M. Blauth,et al.  The effect of in situ augmentation on implant anchorage in proximal humeral head fractures. , 2012, Injury.

[94]  T. Mittlmeier,et al.  Locking plate fixation of humeral head fractures with a telescoping screw. A comparative biomechanical study versus a standard plate. , 2012, Injury.

[95]  C. Bono,et al.  Effect of displacement of fractures of the greater tuberosity on the mechanics of the shoulder. , 2001, The Journal of bone and joint surgery. British volume.

[96]  C. Olsson,et al.  Increased fragility in patients with fracture of the proximal humerus: a case control study. , 2004, Bone.

[97]  P. Varga,et al.  Implicit modeling of screw threads for efficient finite element analysis of complex bone-implant systems. , 2016, Journal of biomechanics.