The analysis of multipole axial flux reluctance resolver with sinusoidal rotor

Because of the axial magnetic circuit structure and special variable reluctance principle, axial flux reluctance resolver has the advantages of compact, small in volume and constant input/output impendence. There are often two kinds of reluctance resolvers: one's reluctance is changed with the length of the airgap and the other's is changed with the airgap coupling area. In this paper, a novel multipole axial flux variable-reluctance resolver is presented, it can improve the resolution of rotor angle and the ability of anti-eccentricity compared with the one pole pair axial resolver. Because of its unsymmetrical structure, 3D FEM time stepping method is used in this paper to obtain the EMF waves in signal windings. The conclusion of FEM analysis proves the correctness of the design of the multipole axial flux reluctance resolver.

[1]  Xu Yongxiang,et al.  The parameter design and calculation for Axial-Flux resistance resolver , 2011, 2011 International Conference on Electrical Machines and Systems.

[2]  Su-Jin Hwang,et al.  A study on the fault diagnosis analysis of variable reluctance resolver for electric vehicle , 2010, 2010 IEEE Sensors.

[3]  Lazhar Ben-Brahim,et al.  A Resolver Angle Estimator Based on Its Excitation Signal , 2009, IEEE Transactions on Industrial Electronics.

[4]  Hu Jianhui,et al.  The capacitor matching problem in the single-phase line-start permanent magnetic synchronous motor , 2008, 2008 International Conference on Electrical Machines and Systems.

[5]  Chengjun Liu,et al.  The analysis for new axial variable reluctance resolver with air-gap complementary structure , 2009, 2009 International Conference on Electrical Machines and Systems.