Evaluation of Power-Ratings for Active Series Filters under Unbalanced Conditions For a Three Phase - Four Wire System

The optimal power rating of a series active filter is important not only in design of compensator for a specific application, but also in determining the best compensation strategy for a specific application. This paper focus mainly on the confront of the power rating of a combined system consisting of two small rating series active filters and a shunt passive filter generally designed for balanced condition, and the power rating required when it's working under unbalanced conditions. This paper highlights the overload imposed to the active series filters for two different degree of imbalance showing that even if the overloaded doesn't exist the system wont be free of harmonic pollution, exceeding the IEEE 519 recommendations

[1]  M. T. Haque,et al.  A novel control strategy for active filters usable in harmonic polluted and/or imbalanced utility voltage case of 3-phase 4-wire distribution systems , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[2]  G. D. Marques,et al.  Design and performance of an active power filter and unbalanced current compensator , 1994, Proceedings of IECON'94 - 20th Annual Conference of IEEE Industrial Electronics.

[3]  Subhashish Bhattacharya,et al.  Synchronous frame based controller implementation for a hybrid series active filter system , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[4]  P. Y. Keskar Specification of variable frequency drive systems to meet the new IEEE 519 standard , 1994, Proceedings of IEEE Pulp and Paper Industry Conference.

[5]  H. Akagi,et al.  A new approach to harmonic compensation in power systems , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[6]  Hirofumi Akagi,et al.  A new power line conditioner for harmonic compensation in power systems , 1995 .

[7]  H. Akagi,et al.  Design strategy for the combined system of shunt passive and series active filters , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[8]  G. Joos,et al.  Performance evaluation of three phase three and four wire active filters , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[9]  H. Akagi,et al.  Compensation characteristics of the combined system of shunt passive and series active filters , 1989, Conference Record of the IEEE Industry Applications Society Annual Meeting,.

[10]  H. Akagi,et al.  A practical approach to harmonic compensation in power systems-series connection of passive and active filters , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[11]  Subhashish Bhattacharya,et al.  Active filter system implementation , 1998 .

[12]  Mauricio Aredes,et al.  New control algorithms for series and shunt three-phase four-wire active power filters , 1995 .

[13]  D. P. Manjure,et al.  Impact of unbalance on power system harmonics , 2002, 10th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.02EX630).