Oxidation/reduction reactions at the metal contact-TlBr interface: an x-ray photoelectron spectroscopy study

TlBr radiation detector operation degrades with time at room temperature and is thought to be due to electromigration of Tl and Br vacancies within the crystal as well as the metal contacts migrating into the TlBr crystal itself due to electrochemical reactions at the metal/TlBr interface. X-ray photoemission spectroscopy (XPS) was used to investigate the metal contact surface/interfacial structure on TlBr devices. Device-grade TlBr was polished and subjected to a 32% HCl etch to remove surface damage prior to Mo or Pt contact deposition. High-resolution photoemission measurements on the Tl 4f, Br 3d, Cl 2p, Mo 3d and Pt 4f core lines were used to evaluate surface chemistry and non-equilibrium interfacial diffusion. Results indicate that anion substitution at the TlBr surface due to the HCl etch forms TlBr1-xClx with consequent formation of a shallow heterojunction. In addition, a reduction of Tl1+ to Tl0 is observed at the metal contacts after device operation in both air and N2 at ambient temperature. Understanding contact/device degradation versus operating environment is useful for improving radiation detector performance.

[1]  I.B. Oliveira,et al.  Influence of crystalline surface quality on TlBr radiation detector performance , 2005, IEEE Transactions on Nuclear Science.

[2]  Zhong He,et al.  TlBr gamma-ray spectrometers using the depth sensitive single polarity charge sensing technique , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[3]  Kanai Shah,et al.  Fabrication Methodology of Enhanced Stability Room Temperature TlBr Gamma Detectors , 2013, IEEE Transactions on Nuclear Science.

[4]  Hao Cui,et al.  Electrocatalytic reduction of bromate ion using a polyaniline-modified electrode: An efficient and green technology for the removal of BrO3− in aqueous solutions , 2010 .

[5]  F. Olschner,et al.  Developing Larger TlBr Detectors—Detector Performance , 2009, IEEE Transactions on Nuclear Science.

[6]  Kanai S. Shah,et al.  Thallium bromide nuclear radiation detector development , 2008 .

[7]  Aron Walsh,et al.  Experimental and theoretical study of the electronic structure of HgO and Tl2O3 , 2005 .

[8]  Kanai S. Shah,et al.  Long-term room temperature stability of TlBr gamma detectors , 2011, Optical Engineering + Applications.

[9]  Jakob Kibsgaard,et al.  Engineering the surface structure of MoS2 to preferentially expose active edge sites for electrocatalysis. , 2012, Nature materials.

[10]  Zhong He,et al.  Investigation of pixelated TlBr gamma-ray spectrometers with the depth-sensing technique , 2008 .

[11]  K. Hitomi,et al.  Polarization Phenomena in TlBr Detectors , 2009, IEEE Transactions on Nuclear Science.