On the Superiority of a Variable Sampling Interval Control Chart

Abstract The paper establishes the analytical grounds of the uniform superiority of a variable sampling interval (VSI) Shewhart control chart over the conventional fixed sampling interval (FSI) control chart, with respect to the zero-time performance, for a wide class of process distributions. We provide a sufficient condition on the distribution of a control chart statistic, and propose a criterion to determine the control limits and the regions in the in-control area of the VSI chart, corresponding to the different sampling intervals used by it. The condition and the criterion together ensure the uniform zero-time superiority of the VSI chart over the matched FSI chart, in detecting a process shift of any magnitude. It is shown that normal, Student's t and Laplace distributions satisfy the sufficient condition. In addition, chi-square, F and beta distributions satisfy it, provided that these are not extremely skewed. Further, it is illustrated that the superiority of the VSI feature is not trivial and cannot be assured if the sufficient condition is not satisfied or the control limits and the regions are not determined according to the proposed criterion. An application of the result to confirm the superiority of the VSI feature is demonstrated for the control chart for individual observations used to monitor a milk-pouch filling process.

[1]  Raid W. Amin,et al.  A Robustness Study of Charts with Variable Sampling Intervals , 1993 .

[2]  Victor R. Prybutok,et al.  Comparison of fixed versus variable samplmg interval shewhart control charts in the presence of positively autocorrelated data , 1997 .

[3]  George C. Runger,et al.  Adaptative sampling for process control , 1991 .

[4]  J. A. Nachlas,et al.  X charts with variable sampling intervals , 1988 .

[5]  Douglas C. Montgomery,et al.  ADAPTIVE SAMPLING ENHANCEMENTS FOR SHEWHART CONTROL CHARTS , 1993 .

[6]  Marion R. Reynolds,et al.  Shewhart and EWMA Variable Sampling Interval Control Charts with Sampling at Fixed Times , 1996 .

[7]  George C. Runger,et al.  Steady-state-optimal adaptive control charts based on variable sampling intervals , 2001 .

[8]  Marion R. Reynolds,et al.  Monitoring the Process Mean and Variance Using Individual Observations and Variable Sampling Intervals , 2001 .

[9]  George Tagaras A Survey of Recent Developments in the Design of Adaptive Control Charts , 1998 .

[10]  Marion R. Reynolds,et al.  Variable sampling intervals for multiparameter shewhart charts , 1989 .

[11]  R Reynolds Marion,et al.  Optimal variable sampling interval control charts , 1989 .

[12]  Marion R. Reynolds,et al.  Optimal one-sided shewhart control charts with variable sampling intervals , 1989 .

[13]  Marion R. Reynolds,et al.  Evaluating properties of variable sampling interval control charts , 1995 .

[14]  Marion R. Reynolds,et al.  Variable-sampling-interval control charts with sampling at fixed times , 1996 .

[15]  Marion R. Reynolds,et al.  Chart with runs and variable sampling intervals , 1988 .

[16]  Marion R. Reynolds,et al.  Variable Sampling Interval X Charts in the Presence of Correlation , 1996 .