The role of outlet temperature of flue gas in organic Rankine cycle considering low temperature corrosion

This paper gives a special focus on the role of outlet temperature of flue gas (Tgo) in organic Rankine cycle (ORC) system for low temperature flue gas waste heat recovery. The variations of performance indicators: net work (Wnet), exergy efficiency (ηex) and levelized energy cost (LEC) versus Tgo are discussed. Considering the corrosion of low temperature flue gas, the necessity and reasonability of limiting Tgo at its minimum allowed discharge temperature (355.15 K) are analyzed. Results show that there exist optimal Tgo (Tgo,opt) for Wnet and LEC, while Tgo,opt for ηex does not appear under the investigated range of Tgo. Moreover, the Tgo,opt for Wnet is always lower than 355.15 K, the Tgo,opt for LEC, despite being greater than the one for Wnet, is just slightly higher than 355.15 K when the inlet temperature of flue gas varies from 408.15 K to 463.15 K. For the waste heat recovery of low temperature flue gas, it is reasonable to fix Tgo at 355.15 K if Wnet or LEC is selected as primary performance indicator under the pinch point temperature difference of evaporator (ΔTe) below 20 K.

[1]  Dimitri Mignard,et al.  Correlating the chemical engineering plant cost index with macro-economic indicators , 2014 .

[2]  Electo Eduardo Silva Lora,et al.  Exergetic and economic comparison of ORC and Kalina cycle for low temperature enhanced geothermal system in Brazil , 2013 .

[3]  You-Rong Li,et al.  Influence of coupled pinch point temperature difference and evaporation temperature on performance of organic Rankine cycle , 2012 .

[4]  J. Van Roy,et al.  Parametric optimization and performance analysis of a waste heat recovery system using Organic Ranki , 2010 .

[5]  Andreas Schuster,et al.  Energetic and economic investigation of Organic Rankine Cycle applications , 2009 .

[6]  Hongguang Zhang,et al.  Optimized performances comparison of organic Rankine cycles for low grade waste heat recovery , 2012 .

[7]  Ashok Misra,et al.  Performance analysis of an Organic Rankine Cycle with superheating under different heat source temperature conditions , 2011 .

[8]  Vahab Hassani,et al.  Value analysis of advanced heat rejection systems for geothermal power plants , 1996, IECEC 96. Proceedings of the 31st Intersociety Energy Conversion Engineering Conference.

[9]  Richard Turton,et al.  Analysis, Synthesis and Design of Chemical Processes , 2002 .

[10]  Olav Bolland,et al.  Working fluids for low-temperature heat source , 2010 .

[11]  Hua Wang,et al.  Optimization of Low-Temperature Exhaust Gas Waste Heat Fueled Organic Rankine Cycle , 2012 .

[12]  Jinliang Xu,et al.  A new design method for Organic Rankine Cycles with constraint of inlet and outlet heat carrier fluid temperatures coupling with the heat source , 2012 .

[13]  Wenhua Li,et al.  Operation optimization of an organic rankine cycle (ORC) heat recovery power plant , 2011 .

[14]  C. F. King Analysis, Synthesis, and Design of Chemical Processes. Richard Turton, Richard Bailie, Wallace Whiting, Joseph Shaeiwitz Prentice Hall, 1998 , 1999 .

[15]  Shan Ren,et al.  Investigation on Co-Combustion Kinetics of Anthracite and Waste Plastics by Thermogravimetric Analysis , 2012 .