Noncontact simultaneous dual wavelength photoplethysmography: a further step toward noncontact pulse oximetry.

We present a camera-based device capable of capturing two photoplethysmographic (PPG) signals at two different wavelengths simultaneously, in a remote noncontact manner. The system comprises a complementary metal-oxide semiconductor camera and dual wavelength array of light emitting diodes (760 and 880 nm). By alternately illuminating a region of tissue with each wavelength of light, and detecting the backscattered photons with the camera at a rate of 16 frames/wavelength s, two multiplexed PPG wave forms are simultaneously captured. This process is the basis of pulse oximetry, and we describe how, with the inclusion of a calibration procedure, this system could be used as a noncontact pulse oximeter to measure arterial oxygen saturation (S(p)O(2)) remotely. Results from an experiment on ten subjects, exhibiting normal S(p)O(2) readings, that demonstrate the instrument's ability to capture signals from a range of subjects under realistic lighting and environmental conditions are presented. We compare the signals captured by the noncontact system to a conventional PPG signal captured concurrently from a finger, and show by means of a J. Bland and D. Altman [Lancet 327, 307 (1986); Statistician 32, 307 (1983)] test, the noncontact device to be comparable to a contact device as a monitor of heart rate. We highlight some considerations that should be made when using camera-based "integrative" sampling methods and demonstrate through simulation, the suitability of the captured PPG signals for application of existing pulse oximetry calibration procedures.

[1]  Douglas G. Altman,et al.  Measurement in Medicine: The Analysis of Method Comparison Studies , 1983 .

[2]  F G Shellock,et al.  Severe burn of the finger caused by using a pulse oximeter during MR imaging. , 1989, AJR. American journal of roentgenology.

[3]  K. Hayakawa,et al.  Mechanism of burn injury during magnetic resonance imaging (MRI)--simple loops can induce heat injury. , 2001, Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering.

[4]  J. Severinghaus,et al.  History, status and future of pulse oximetry. , 1987, Advances in experimental medicine and biology.

[5]  P. Rolfe,et al.  In vivo near-infrared spectroscopy. , 2000, Annual review of biomedical engineering.

[6]  Clare E. Elwell,et al.  A Practical Users Guide to Near Infrared Spectroscopy , 1995 .

[7]  D. Delpy,et al.  Optical pathlength measurements on adult head, calf and forearm and the head of the newborn infant using phase resolved optical spectroscopy. , 1995, Physics in medicine and biology.

[8]  Tomas E. Ward,et al.  A CMOS camera-based system for clinical photoplethysmographic applications , 2005, SPIE OPTO-Ireland.

[9]  M W Wukitsch,et al.  Pulse oximetry: Historical review and Ohmeda functional analysis , 1987, International journal of clinical monitoring and computing.

[10]  F. Mastik,et al.  Contactless Multiple Wavelength Photoplethysmographic Imaging: A First Step Toward “SpO2 Camera” Technology , 2005, Annals of Biomedical Engineering.

[11]  J. Whitwam,et al.  The accuracy of pulse oximeters , 1988, Anaesthesia.

[12]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[13]  John G. Webster,et al.  Design of Pulse Oximeters , 1997 .

[14]  P.D. Mannheimer,et al.  Wavelength selection for low-saturation pulse oximetry , 1997, IEEE Transactions on Biomedical Engineering.

[15]  M. Wukitsch,et al.  Pulse oximetry: Analysis of theory, technology, and practice , 1988, Journal of Clinical Monitoring.

[16]  J. C. Dorlas,et al.  Photo-electric plethysmography as a monitoring device in anaesthesia. Application and interpretation. , 1985, British journal of anaesthesia.

[17]  E. Abraham,et al.  Postoperative monitoring of conjunctival oxygen tension and temperature , 1988, International journal of clinical monitoring and computing.

[18]  L. Tarassenko,et al.  The effect of varying LED intensity on pulse oximeter accuracy. , 1991, Journal of medical engineering & technology.

[19]  B. Goldstein,et al.  SEVERE BURNS RESULTING FROM MAGNETIC RESONANCE IMAGING WITH CARDIOPULMONARY MONITORING: Risks and Relevant Safety Precautions , 1993, American journal of physical medicine & rehabilitation.

[20]  Takuo Aoyagi,et al.  Pulse oximetry: its invention, theory, and future , 2003, Journal of Anesthesia.