Within-day reliability of shoulder range of motion measurement with a smartphone.

Measuring range of motion (ROM) is the first step of a physical examination and functional evaluation of the shoulder joint. Digital inclinometers are available on the market; however, they are expensive, and hence will not come into wide use. In this study, we present a new method for the shoulder ROM measurement using the inclinometer application on a smartphone. We hypothesized that the method would demonstrate acceptable reliability and reproducibility. Three observers performed goniometric and smartphone inclinometric measurements of various shoulder movements, including both active and passive ROM for forward flexion, abduction, external rotation while the arms are at the sides, external rotation at 90° abduction, and internal rotation at 90° abduction. Measurements were performed in the affected shoulders of 41 patients. All measurements were taken twice to assess the intra-observer reliability. Inter- and intra-observer reliabilities were evaluated using the intraclass correlation coefficient (ICC). Reliability between two measurements was also assessed in terms of the ICC. Both the goniometric and inclinometric measurements showed satisfactory inter-observer reliability except for internal rotation at 90° abduction for which the ICC value was <0.7 (range, 0.63-0.68). Intra-observer reliability was excellent with an ICC value>0.9, except for some movements. Within-day inclinometric measurements with a smartphone showed acceptable reliability compared to the classical goniometric measurements of movements and the correlation between the two measurements was fairly high. Considering convenience and cost-effectiveness, this new method could be widely used for measuring the shoulder ROM, although the between-day reliability needs to be established first.

[1]  R. Buchbinder,et al.  How reliably do rheumatologists measure shoulder movement? , 2002, Annals of the rheumatic diseases.

[2]  E. Bautz-Holter,et al.  Range of shoulder motion in patients with adhesive capsulitis; Intra-tester reproducibility is acceptable for group comparisons , 2008, BMC musculoskeletal disorders.

[3]  C. Terwee,et al.  Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer , 2004, BMC musculoskeletal disorders.

[4]  Richard W. Bohannon,et al.  Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity. , 1987, Physical therapy.

[5]  R. Buchbinder,et al.  A standardized protocol for measurement of range of movement of the shoulder using the Plurimeter-V inclinometer and assessment of its intrarater and interrater reliability. , 1998, Arthritis care and research : the official journal of the Arthritis Health Professions Association.

[6]  Jeremy S. Lewis,et al.  Intraobserver reliability of 4 physiologic movements of the shoulder in subjects with and without symptoms. , 2006, Archives of physical medicine and rehabilitation.

[7]  Joseph L. Fleiss,et al.  A NEW VIEW OF INTER‐OBSERVER AGREEMENT , 1963 .

[8]  G. Murrell,et al.  Reliability of five methods for assessing shoulder range of motion. , 2001, The Australian journal of physiotherapy.

[9]  J. M. Rothstein,et al.  Goniometric Reliability in a Clinical Setting , 1983 .

[10]  G Atkinson,et al.  Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine , 1998, Sports medicine.

[11]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[12]  Kathleenl N. Lohr,et al.  Assessing health status and quality-of-life instruments: Attributes and review criteria , 2002, Quality of Life Research.

[13]  M. Mullaney,et al.  Reliability of shoulder range of motion comparing a goniometer to a digital level , 2010, Physiotherapy theory and practice.

[14]  P. McNair,et al.  Reliability of a new hand-held dynamometer in measuring shoulder range of motion and strength. , 2011, Manual therapy.

[15]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[16]  Tony Malim,et al.  Perspectives in psychology , 1992 .

[17]  M. Kolber,et al.  The reliability and minimal detectable change of shoulder mobility measurements using a digital inclinometer , 2011, Physiotherapy theory and practice.

[18]  J M Rothstein,et al.  Goniometric reliability in a clinical setting. Shoulder measurements. , 1987, Physical therapy.