Evaluating and Upgrading Welded Steel Moment-Frame Buildings Using FEMA-351
暂无分享,去创建一个
In July 2000, the SAC Joint Venture (a joint venture of the Structural Engineers Association of California, the Applied Technology Council, and California Universities for Research in Earthquake Engineering) prepared a series of recommendations regarding welded steel moment-frame design, evaluation, and upgrade procedures. FEMA-351, Recommended Seismic Evaluation and Upgrade Criteria for Existing Welded Steel Moment-Frame Buildings, was developed to evaluate the probable performance of existing steel moment-frame buildings in future earthquakes and to provide guidance or upgrading these buildings. The procedures introduced in FEMA-351 allow the determination of the level of confidence a structure will be able to achieve based on a specified performance objective, using simplified analytical methods. Simplified procedures for estimating the probable post-earthquake repair costs and nonstructural damage, based on the losses incurred in the 1994 Northridge earthquake, are presented as well. This paper provides a brief chapter-by-chapter overview of the information contained in FEMA-351 and emphasizes the performance evaluation procedures by stepping through the process using an example building.
[1] W. J. Hall,et al. Recommended Seismic Evaluation and Upgrade Criteria for Existing Welded Steel Moment-Frame Buildings , 2000 .
[2] W. J. Hall,et al. Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings , 2001 .
[3] Lawrence D. Reaveley,et al. Recommended Specifications and Quality Assurance Guidelines for Steel Moment-Frame Construction for Seismic Applications , 2000 .