Local heating of human skin by millimeter waves: A kinetics study

Heating rates of human skin exposed locally to 42.25 GHz mm waves, coming from a waveguide (WG) opening or a YAV device designed for therapeutic application, were studied in vivo using infrared (IR) thermography. For both radiators, the power density distribution was described by a circularly symmetrical Gaussian type function on the exposed skin surface. Insertion of a small thermocouple (d = 0.1 mm) in the exposed area did not produce any significant artifact, either in the power density distribution or kinetics measurement, providing it was perpendicular to the E vector. The heating kinetics in the skin exposed with either the WG opening or the YAV device were well fitted to solutions of the 2-D bio-heat transfer equation for homogeneous tissue. Changes in irradiating beam size (1-8 mm) had no detectable effect on the initial (0.3-3.0 s) phase of the heating kinetics. However, the amplitude of the kinetics decreased substantially with decreasing the beam size. As the temperature rise in the time interval necessary for reliable measurement of the initial temperature rise rate was very small, an accurate experimental determination of specific absorption rate (SAR) becomes practically impossible at the low intensities normally used in our experiments. The correct SAR values may be found from fitting of the model to the heating kinetics. Bioelectromagnetics 24:571-581, 2003.

[1]  J. Jaeger Conduction of heat in tissue supplied with blood , 1952 .

[2]  Lisa X. Xu,et al.  Estimation of blood perfusion using phase shift in temperature response to sinusoidal heating at the skin surface , 1999, IEEE Transactions on Biomedical Engineering.

[3]  K. Foster,et al.  Effect of Surface Cooling and Blood Flow on the Microwave Heating of Tissue , 1978, IEEE Transactions on Biomedical Engineering.

[4]  T. Walters,et al.  Heating and pain sensation produced in human skin by millimeter waves: comparison to a simple thermal model. , 2000, Health physics.

[5]  H. A. Luther,et al.  Applied numerical methods , 1969 .

[6]  Stanislav I. Alekseev,et al.  Distortion of millimeter-wave absorption in biological media due to presence of thermocouples and other objects , 2001, IEEE Transactions on Biomedical Engineering.

[7]  R. Adair,et al.  Biophysical limits on athermal effects of RF and microwave radiation , 2003, Bioelectromagnetics.

[8]  P. A. Mason,et al.  Skin heating effects of millimeter-wave irradiation-thermal modeling results , 2000 .

[9]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .

[10]  M C Ziskin,et al.  Reflection and absorption of millimeter waves by thin absorbing films. , 2000, Bioelectromagnetics.

[11]  Robert B. Roemer,et al.  A Mathematical Model of the Human Temperature Regulatory System - Transient Cold Exposure Response , 1976, IEEE Transactions on Biomedical Engineering.

[12]  K R Foster,et al.  Heating of tissues by microwaves: a model analysis. , 1998, Bioelectromagnetics.

[13]  P. Riu,et al.  Heating of tissue by near-field exposure to a dipole: a model analysis , 1999, IEEE Transactions on Biomedical Engineering.

[14]  J. Crank,et al.  A practical method for numerical evaluation of solutions of partial differential equations of the heat-conduction type , 1947 .

[15]  M C Ziskin,et al.  Millimeter waves thermally alter the firing rate of the Lymnaea pacemaker neuron. , 1997, Bioelectromagnetics.

[16]  W. Wulff,et al.  The Energy Conservation Equation for Living Tissue , 1974 .

[17]  H. N. Kritikos,et al.  Potential Temperature Rise Induced by Electromagnetic Field in Brain Tissues , 1979, IEEE Transactions on Biomedical Engineering.

[18]  O. Gandhi,et al.  Absorption of Millimeter Waves by Human Beings and its Biological Implications , 1986 .

[19]  E.P. Khizhnyak,et al.  Heating patterns in biological tissue phantoms caused by millimeter wave electromagnetic irradiation , 1994, IEEE Transactions on Biomedical Engineering.