Wire Gabion for Protecting Bridge Piers

As a new alternative countermeasure to riprap for scour protection around bridge piers, wire gabions were investigated experimentally for failure mechanisms, effects of significant parameters on failure and its sizing in a clear-water condition. The dominating failure mechanism was found to be a shear failure. Based on the experimental data, the controlling factors for the stability of wire gabions as a scour countermeasure at the pier are flow depth relative to pier diameter, length to thickness ratio, coverage, alignment and placement depth of wire gabions. An equation for sizing of a wire gabion is proposed in terms of Froude number and factors reflecting both the effect and limit of significant parameters. Comparison of the equation with those of ripraps shows that smaller wire gabions than ripraps provide an equivalent protection implying cost effective and improved stability.