Fully Actuated Body-Mounted Robotic System for MRI-Guided Lower Back Pain Injections: Initial Phantom and Cadaver Studies

This letter reports the improved design, system integration, and initial experimental evaluation of a fully actuated body-mounted robotic system for real-time MRI-guided lower back pain injections. The 6-DOF robot is composed of a 4-DOF needle alignment module and a 2-DOF remotely actuated needle driver module, which together provide a fully actuated manipulator that can operate inside the scanner bore during imaging. The system minimizes the need to move the patient in and out of the scanner during a procedure, and thus may shorten the procedure time and streamline the clinical workflow. The robot is devised with a compact and lightweight structure that can be attached directly to the patient's lower back via straps. This approach minimizes the effect of patient motion by allowing the robot to move with the patient. The robot is integrated with an image-based surgical planning module. A dedicated clinical workflow is proposed for robot-assisted lower back pain injections under real-time MRI guidance. Targeting accuracy of the system was evaluated with a real-time MRI-guided phantom study, demonstrating the mean absolute errors (MAE) of the tip position to be 1.50 <inline-formula><tex-math notation="LaTeX">$\pm$</tex-math></inline-formula> 0.68 mm and of the needle angle to be 1.56 <inline-formula><tex-math notation="LaTeX">$\pm \; \text{0.93}^\circ$</tex-math></inline-formula>. An initial cadaver study was performed to validate the feasibility of the clinical workflow, indicating the maximum error of the position to be less than 1.90 mm and of the angle to be less than 3.14 <inline-formula><tex-math notation="LaTeX">$^\circ$</tex-math></inline-formula>.

[1]  Kevin Cleary,et al.  An integrated MR imaging coil and body-mounted robot for MR-guided pediatric arthrography: SNR and phantom study , 2019, Medical Imaging.

[2]  Mehran Anvari,et al.  An image‐guided automated robot for MRI breast biopsy , 2016, The international journal of medical robotics + computer assisted surgery : MRCAS.

[3]  Faye Y. Wu,et al.  An MRI Coil-Mounted Multi-Probe Robotic Positioner for Cryoablation , 2013 .

[4]  Ge Fang,et al.  Design of a Percutaneous MRI-Guided Needle Robot With Soft Fluid-Driven Actuator , 2020, IEEE Robotics and Automation Letters.

[5]  Iulian Iordachita,et al.  A Fully Actuated Body-Mounted Robotic Assistant for MRI-Guided Low Back Pain Injection , 2020, 2020 IEEE International Conference on Robotics and Automation (ICRA).

[6]  Nobuhiko Hata,et al.  System Integration and Preliminary Clinical Evaluation of a Robotic System for MRI-Guided Transperineal Prostate Biopsy , 2019, J. Medical Robotics Res..

[7]  Kevin Cleary,et al.  MRI Robots for Needle-Based Interventions: Systems and Technology , 2018, Annals of Biomedical Engineering.

[8]  Mihailo Ristic,et al.  Needle-Guiding Robot for Laser Ablation of Liver Tumors Under MRI Guidance , 2016, IEEE/ASME Transactions on Mechatronics.

[9]  Hao Su,et al.  Robotic System for MRI-Guided Stereotactic Neurosurgery , 2015, IEEE Transactions on Biomedical Engineering.

[10]  L F Wilson,et al.  Back pain in children and adolescents. , 2014, The bone & joint journal.

[11]  Alexandre Moreau-Gaudry,et al.  Evaluation of the Needle Positioning Accuracy of a Light Puncture Robot Under MRI Guidance: Results of a Clinical Trial on Healthy Volunteers , 2018, CardioVascular and Interventional Radiology.

[12]  Ming Li,et al.  MRI robot for prostate focal laser ablation: a phantom study , 2019, Medical Imaging.

[13]  Kemal Tuncali,et al.  Configurable Automatic Detection and Registration of Fiducial Frames for Device-to-Image Registration in MRI-Guided Prostate Interventions , 2013, MICCAI.

[14]  J. Carrino,et al.  MRI‐guided interventions of the musculoskeletal system , 2008, Journal of magnetic resonance imaging : JMRI.

[15]  Di Wu,et al.  Remotely Actuated Needle Driving Device for MRI-Guided Percutaneous Interventions , 2019, 2019 International Symposium on Medical Robotics (ISMR).

[16]  Gabor Fichtinger,et al.  Augmented reality visualization with image overlay for MRI-guided intervention: accuracy for lumbar spinal procedures with a 1.5-T MRI system. , 2012, AJR. American journal of roentgenology.

[17]  Dan Stoianovici,et al.  MR Safe Robot, FDA Clearance, Safety and Feasibility of Prostate Biopsy Clinical Trial , 2017, IEEE/ASME Transactions on Mechatronics.

[18]  Nobuhiko Hata,et al.  Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy , 2015, IEEE/ASME Transactions on Mechatronics.

[19]  Kevin Cleary,et al.  Body-mounted robotic assistant for MRI-guided low back pain injection , 2020, International Journal of Computer Assisted Radiology and Surgery.

[20]  Jan Fritz,et al.  Management of chronic low back pain: rationales, principles, and targets of imaging-guided spinal injections. , 2007, Radiographics : a review publication of the Radiological Society of North America, Inc.

[21]  Kemal Tuncali,et al.  Motion compensation for MRI-compatible patient-mounted needle guide device: estimation of targeting accuracy in MRI-guided kidney cryoablations. , 2018, Physics in medicine and biology.

[22]  Garnette R. Sutherland,et al.  The Development of Robotics for Interventional MRI , 2009 .

[23]  Jan Fritz,et al.  3-Tesla High-Field Magnetic Resonance Neurography for Guiding Nerve Blocks and Its Role in Pain Management. , 2015, Magnetic resonance imaging clinics of North America.

[24]  Jaydev P. Desai,et al.  Toward the Development of a Flexible Mesoscale MRI-Compatible Neurosurgical Continuum Robot , 2017, IEEE Transactions on Robotics.