Simultaneous BOLD/perfusion measurement using dual-echo FAIR and UNFAIR: sequence comparison at 1.5T and 3.0T.

Functional MRI (fMRI) studies designed for simultaneously measuring Blood Oxygenation Level Dependent (BOLD) and Cerebral Blood Flow (CBF) signal often employ the standard Flow Alternating Inversion Recovery (FAIR) technique. However, some sensitivity is lost in the BOLD data due to inherent T1 relaxation. We sought to minimize the preceding problem by employing a modified UN-inverted FAIR (UNFAIR) technique, which (in theory) should provide identical CBF signal as FAIR with minimal degradation of the BOLD signal. UNFAIR BOLD maps acquired from human subjects (n = 8) showed significantly higher mean z-score of approximately 17% (p < 0.001), and number of activated voxels at 1.5T. On the other hand, the corresponding FAIR perfusion maps were superior to the UNFAIR perfusion maps as reflected in a higher mean z-score of approximately 8% (p = 0.013), and number of activated voxels. The reduction in UNFAIR sensitivity for perfusion is attributed to increased motion sensitivity related to its higher background signal, and, T2 related losses from the use of an extra inversion pulse. Data acquired at 3.0T demonstrating similar trends are also presented.

[1]  G. Crelier,et al.  Stimulus-Dependent BOLD and Perfusion Dynamics in Human V1 , 1999, NeuroImage.

[2]  M O Leach,et al.  Implementation and evaluation of frequency offset corrected inversion (FOCI) pulses on a clinical MR system , 1997, Magnetic resonance in medicine.

[3]  D. Weinberger,et al.  Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST) , 2000, Magnetic resonance in medicine.

[4]  S G Kim,et al.  Multi‐slice perfusion‐based functional MRI using the FAIR technique: comparison of CBF and BOLD effects , 1997, NMR in biomedicine.

[5]  Hoult,et al.  Selective spin inversion in nuclear magnetic resonance and coherent optics through an exact solution of the Bloch-Riccati equation. , 1985, Physical review. A, General physics.

[6]  J. Helpern,et al.  Perfusion imaging by un-inverted flow-sensitive alternating inversion recovery (UNFAIR). , 1997, Magnetic resonance imaging.

[7]  R. Ordidge,et al.  Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy , 1996, Magnetic resonance in medicine.

[8]  D. Tank,et al.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation. , 1990, Proceedings of the National Academy of Sciences of the United States of America.

[9]  J. Duyn,et al.  High‐sensitivity single‐shot perfusion‐weighted fMRI † , 2001, Magnetic resonance in medicine.

[10]  Yihong Yang,et al.  Multislice perfusion imaging in human brain using the C‐FOCI inversion pulse: Comparison with hyperbolic secant , 1999, Magnetic resonance in medicine.

[11]  J L Tanabe,et al.  MR perfusion imaging in human brain using the UNFAIR technique , 1999, Journal of magnetic resonance imaging : JMRI.

[12]  Seong-Gi Kim Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping , 1995, Magnetic resonance in medicine.

[13]  T. L. Davis,et al.  Mr perfusion studies with t1‐weighted echo planar imaging , 1995, Magnetic resonance in medicine.

[14]  R B Buxton,et al.  Slice profile effects in adiabatic inversion: Application to multislice perfusion imaging , 1997, Magnetic resonance in medicine.

[15]  S. Ogawa Brain magnetic resonance imaging with contrast-dependent oxygenation , 1990 .

[16]  Egill Rostrup,et al.  Determination of relative CMRO2 from CBF and BOLD changes: Significant increase of oxygen consumption rate during visual stimulation , 1999, Magnetic resonance in medicine.