Factors related to Periotest values in endosseal implants: a 9-year follow-up.

Periotest values (PTV) of successful endosseal implants of 2 one-stage implant systems. TPS and ITI, were followed from 3 months to 9 years in order to determine the factors that contribute to the values. 128 TPS screw implants were inserted in the lower jaw of 34 subjects, (mean age 55 years), for retaining overdentures. 108 ITI implants were inserted in the upper and lower jaws in 50 subjects (mean age 42 years), for retaining overdentures, crowns and bridges. PTVs were first measured after the osseointegration period and thereafter annually. First of all there was a difference between the 2 implant systems. Mean PTVs of TPS bicortical screws were significantly lower (P < 0.05) than those of ITI implants (screws, hollow-screws, hollow-cylinders). Factors which significantly contributed to PTVs of ITI implants were jaw (upper/lower), implant length and region of the jaw in which the implant was inserted. PTVs of ITI implants in the lower jaw were lower than in the upper jaw (P < 0.05). The length of implant had no effect on PTVs in the lower jaw, but in the upper jaw, PTVs of ITI 8-10-mm implants were lower than 12-mm implants (P < 0.05). PTVs of implants inserted in the anterior region of the upper jaw were higher than those in the posterior region (P < 0.05). In conclusion, bone quality and implant length had a statistically significant effect on implant mobility in long-term follow-up. PTVs of various implant systems, however, differ, a fact that must be taken into account in evaluating the success of implants.

[1]  J. Ottervanger,et al.  Clinical evaluation of mandibular overdentures supported by multiple-bar fabrication: a follow-up study of two implant systems. , 1995, The International journal of oral & maxillofacial implants.

[2]  R. Haas,et al.  Examination of the damping behavior of IMZ implants. , 1995, The International journal of oral & maxillofacial implants.

[3]  R. Mericske-Stern,et al.  Periotest measurements and osseointegration of mandibular ITI implants supporting overdentures. A one-year longitudinal study. , 1995, Clinical oral implants research.

[4]  M. Hartikainen,et al.  Prosthetic possibilities using endosseal implants as anchorages--an epidemiological study in 65-year-old subjects. , 1995, Journal of oral rehabilitation.

[5]  M. Hartikainen,et al.  General and local contraindications for endosseal implants--an epidemiological panoramic radiograph study in 65-year-old subjects. , 1995, Community dentistry and oral epidemiology.

[6]  H Spiekermann,et al.  A 10-year follow-up study of IMZ and TPS implants in the edentulous mandible using bar-retained overdentures. , 1995, The International journal of oral & maxillofacial implants.

[7]  G Faulkner,et al.  Assessment of the periotest device in baseline mobility measurements of craniofacial implants. , 1995, The International journal of oral & maxillofacial implants.

[8]  T. Kaneko Relationship between the stiffness of the dental implant-bone system and the duration of the implant-tapping rod contact. , 1994, Medical engineering & physics.

[9]  A. Raustia,et al.  Clinical and radiologic assessment of possibilities for endosseous implants and osseointegrated prostheses in 55-year-old edentulous subjects. , 1994, Acta odontologica Scandinavica.

[10]  K. Oikarinen,et al.  Influence of arch bar splinting on periodontium and mobility of fixed teeth. , 1994, Acta odontologica Scandinavica.

[11]  J. Medige,et al.  Assessment of oral implant mobility. , 1993, The Journal of prosthetic dentistry.

[12]  K. Oikarinen,et al.  Failures in the osseointegration of endosseous implants. , 1993, The International journal of oral & maxillofacial implants.

[13]  D van Steenberghe,et al.  A study of 589 consecutive implants supporting complete fixed prostheses. Part I: Periodontal aspects. , 1992, The Journal of prosthetic dentistry.

[14]  J. Andreasen,et al.  Rigidity of various fixation methods used as dental splints. , 1992, Endodontics & dental traumatology.

[15]  K. Oikarinen,et al.  Mobility and percussion sound of healthy upper incisors and canines. , 1992, Endodontics & dental traumatology.

[16]  M. Quirynen,et al.  Periodontal aspects of osseointegrated fixtures supporting an overdenture. A 4-year retrospective study. , 1991, Journal of clinical periodontology.

[17]  D van Steenberghe,et al.  Periotest: an objective clinical diagnosis of bone apposition toward implants. , 1991, The International journal of oral & maxillofacial implants.

[18]  J. Lahti,et al.  Prognosis of permanent teeth in the line of mandibular fractures. , 1990, Endodontics & dental traumatology.

[19]  C Aparicio,et al.  Periotest method as a measure of osseointegrated oral implant stability. , 1990, The International journal of oral & maxillofacial implants.

[20]  D. Misiek,et al.  Titanium plasma-sprayed (TPS) screw implants for the reconstruction of the edentulous mandible. , 1986, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[21]  G Zarb,et al.  The long-term efficacy of currently used dental implants: a review and proposed criteria of success. , 1986, The International journal of oral & maxillofacial implants.

[22]  A Tallgren,et al.  The continuing reduction of the residual alveolar ridges in complete denture wearers: a mixed-longitudinal study covering 25 years. , 2003, The Journal of prosthetic dentistry.