Analytical Study on the Heating Performance Improvement of a CO 2 Heat Pump Using Vapor Injection

ABSTRACT: In this study, a simulation model for a CO 2 heat pump using vapor injection was developed and validated. It was used to predict the improvement of the heating performance of the CO 2 heat pump at various operating conditions. The simulation results showed consistent results with the measured data. The heating performances of the vapor injection and non-injection heat pumps were compared by varying the outdoor temperature and compressor frequency. The heating capacity of the vapor injection heat pump was 40% higher than that of the non-injection heat pump at the outdoor temperature of -8℃. The performance of the vapor injection heat pump was consistently higher than that of the non-injection heat pump even when the compressor frequency was reduced to 35 Hz at the outdoor temperature of -3℃.Keywords: CO 2 heat pump(이산화탄소 열펌프), Vapor injection(가스인젝션), Simulation(시뮬레이션) †Corresponding author Tel.: +82-2-3290-3366; fax: +82-2-921-5439 E-mail address: yongckim@korea.ac.kr 기 호 설 명