Rapid optimization of MRM-MS instrument parameters by subtle alteration of precursor and product m/z targets.

Multiple reaction monitoring (MRM) is a highly sensitive method of targeted mass spectrometry (MS) that can be used to selectively detect and quantify peptides based on the screening of specified precursor peptide-to-fragment ion transitions. MRM-MS sensitivity depends critically on the tuning of instrument parameters, such as collision energy and cone voltage, for the generation of maximal product ion signal. Although generalized equations and values exist for such instrument parameters, there is no clear indication that optimal signal can be reliably produced for all types of MRM transitions using such an algorithmic approach. To address this issue, we have devised a workflow functional on both Waters Quattro Premier and ABI 4000 QTRAP triple quadrupole instruments that allows rapid determination of the optimal value of any programmable instrument parameter for each MRM transition. Here, we demonstrate the strategy for the optimizations of collision energy and cone voltage, but the method could be applied to other instrument parameters, such as declustering potential, as well. The workflow makes use of the incremental adjustment of the precursor and product m/z values at the hundredth decimal place to create a series of MRM targets at different collision energies that can be cycled through in rapid succession within a single run, avoiding any run-to-run variability in execution or comparison. Results are easily visualized and quantified using the MRM software package Mr. M to determine the optimal instrument parameters for each transition.

[1]  Sándor Suhai,et al.  Fragmentation pathways of protonated peptides. , 2005, Mass spectrometry reviews.

[2]  R. Aebersold,et al.  High Sensitivity Detection of Plasma Proteins by Multiple Reaction Monitoring of N-Glycosites*S , 2007, Molecular & Cellular Proteomics.

[3]  James C. Marsters,et al.  Selective Detection of Membrane Proteins Without Antibodies , 2002, Molecular & Cellular Proteomics.

[4]  Nichole L. King,et al.  Development and validation of a spectral library searching method for peptide identification from MS/MS , 2007, Proteomics.

[5]  Leigh Anderson,et al.  Quantitative Mass Spectrometric Multiple Reaction Monitoring Assays for Major Plasma Proteins* , 2006, Molecular & Cellular Proteomics.

[6]  Vicki H. Wysocki,et al.  Influence of Peptide Composition, Gas-Phase Basicity, and Chemical Modification on Fragmentation Efficiency: Evidence for the Mobile Proton Model , 1996 .

[7]  S. Carr,et al.  Quantitative, Multiplexed Assays for Low Abundance Proteins in Plasma by Targeted Mass Spectrometry and Stable Isotope Dilution*S , 2007, Molecular & Cellular Proteomics.

[8]  David M Bunk,et al.  Development and evaluation of a reference measurement procedure for the determination of total 3,3',5-triiodothyronine in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry. , 2004, Analytical chemistry.

[9]  D. Lauffenburger,et al.  Multiple reaction monitoring for robust quantitative proteomic analysis of cellular signaling networks , 2007, Proceedings of the National Academy of Sciences.

[10]  Damon May,et al.  MRMer, an Interactive Open Source and Cross-platform System for Data Extraction and Visualization of Multiple Reaction Monitoring Experiments*S⃞ , 2008, Molecular & Cellular Proteomics.

[11]  Eugene A. Kapp,et al.  Mining a tandem mass spectrometry database to determine the trends and global factors influencing peptide fragmentation. , 2003, Analytical chemistry.

[12]  Sándor Suhai,et al.  Towards understanding the tandem mass spectra of protonated oligopeptides. 1: Mechanism of amide bond cleavage , 2004, Journal of the American Society for Mass Spectrometry.

[13]  George C Tseng,et al.  Statistical characterization of the charge state and residue dependence of low-energy CID peptide dissociation patterns. , 2005, Analytical chemistry.

[14]  V. Wysocki,et al.  Mobile and localized protons: a framework for understanding peptide dissociation. , 2000, Journal of mass spectrometry : JMS.

[15]  R. Kostiainen,et al.  Liquid chromatography/atmospheric pressure ionization-mass spectrometry in drug metabolism studies. , 2003, Journal of mass spectrometry : JMS.

[16]  M. Lee,et al.  LC/MS applications in drug development. , 2002, Mass spectrometry reviews.

[17]  Ruedi Aebersold,et al.  The standard protein mix database: a diverse data set to assist in the production of improved Peptide and protein identification software tools. , 2008, Journal of proteome research.