PET quantitation and imaging of the non-pure positron-emitting iodine isotope 124I.

A series of PET studies using phantoms is presented to characterize the imaging and quantitative performance of the positron-emitting iodine isotope 124I. Measurements were performed on the 2D-PET scanner GE 4096+ as well as on the Siemens PET scanner HRR+ operated in both 2D and 3D modes. No specific correction was applied for the gamma-rays emitted together with the positrons. As compared to 18F, in studies with 124I there is a small loss of image resolution and contrast, and an increase in background. The quantitative results varied between different scanners and various acquisition as well as reconstruction modes, with an average relative difference of -6 +/- 13% (mean+/-SD) in respect of the phantom radioactivity as measured with gamma-ray spectroscopy. We conclude that quantitation of a radiopharmaceutical labelled with 124I is feasible and may be improved by the development of specific corrections.

[1]  G Brix,et al.  Performance evaluation of a whole-body PET scanner using the NEMA protocol. National Electrical Manufacturers Association. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  Icrp Radionuclide Transformations : Energy and Intensity of Emissions. , 1983 .

[3]  D. Newport,et al.  Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging , 1995 .

[4]  C. C. Watson,et al.  New, faster, image-based scatter correction for 3D PET , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[5]  Michel Defrise,et al.  Exact and approximate rebinning algorithms for 3-D PET data , 1997, IEEE Transactions on Medical Imaging.

[6]  M Defrise,et al.  Three-dimensional image reconstruction from complete projections , 1989, Physics in medicine and biology.

[7]  H. Herzog,et al.  SPECT studies of brain tumors with L-3-[123I] iodo-alpha-methyl tyrosine: comparison with PET, 124IMT and first clinical results. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  Z. Kovács,et al.  Excitation functions of 124Te(p, xn)124,123I reactions from 6 to 31 MeV with special reference to the production of 124I at a small cyclotron , 1995 .

[9]  C. Bohm,et al.  Correction for Scattered Radiation in a Ring Detector Positron Camera by Integral Transformation of the Projections , 1983, Journal of computer assisted tomography.

[10]  E. Rota Kops,et al.  Performance characteristics of an eight-ring whole body PET scanner. , 1990, Journal of computer assisted tomography.

[11]  K. Dutschka,et al.  N.c.a. radiosynthesis of [123,124I]beta-CIT, plasma analysis and pharmacokinetic studies with SPECT and PET. , 1995, Nuclear medicine and biology.

[12]  D. L. Morrison,et al.  Excitation Functions of ( p , xp ) Reactions , 1962 .

[13]  K S Pentlow,et al.  Quantitative imaging of iodine-124 with PET. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  H. Coenen,et al.  Excitation functions of 124Te(d,xn)124,125I reactions from threshold up to 14 MeV: comparative evaluation of nuclear routes for the production of 124I. , 2001, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.