Cerebral Blood Flow Measurement Using fMRI and PET: A Cross-Validation Study

An important aspect of functional magnetic resonance imaging (fMRI) is the study of brain hemodynamics, and MR arterial spin labeling (ASL) perfusion imaging has gained wide acceptance as a robust and noninvasive technique. However, the cerebral blood flow (CBF) measurements obtained with ASL fMRI have not been fully validated, particularly during global CBF modulations. We present a comparison of cerebral blood flow changes (ΔCBF) measured using a flow-sensitive alternating inversion recovery (FAIR) ASL perfusion method to those obtained using H2 15O PET, which is the current gold standard for in vivo imaging of CBF. To study regional and global CBF changes, a group of 10 healthy volunteers were imaged under identical experimental conditions during presentation of 5 levels of visual stimulation and one level of hypercapnia. The CBF changes were compared using 3 types of region-of-interest (ROI) masks. FAIR measurements of CBF changes were found to be slightly lower than those measured with PET (average ΔCBF of 21.5 ± 8.2% for FAIR versus 28.2 ± 12.8% for PET at maximum stimulation intensity). Nonetheless, there was a strong correlation between measurements of the two modalities. Finally, a t-test comparison of the slopes of the linear fits of PET versus ASL ΔCBF for all 3 ROI types indicated no significant difference from unity (P > .05).

[1]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[2]  R. Buxton,et al.  Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II) , 1998 .

[3]  G. Bruce Pike,et al.  The effect of global cerebral vasodilation on focal activation hemodynamics , 2006, NeuroImage.

[4]  Anne M. Smith,et al.  Absolute CBF and CBV measurements by MRI bolus tracking before and after acetazolamide challenge: Repeatabilily and comparison with PET in humans , 2005, NeuroImage.

[5]  P T Fox,et al.  Perfusion‐weighted imaging of interictal hypoperfusion in temporal lobe epilepsy using FAIR‐HASTE: Comparison with H215O PET measurements , 2001, Magnetic resonance in medicine.

[6]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[7]  Alan C. Evans,et al.  A General Statistical Analysis for fMRI Data , 2000, NeuroImage.

[8]  Magnus Dahlbom,et al.  PET system calibrations and corrections for quantitative and spatially accurate images , 1989 .

[9]  Alan C. Evans,et al.  Cerebral [15O]Water Clearance in Humans Determined by PET: I. Theory and Normal Values , 1996, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[10]  G. Crelier,et al.  Investigation of BOLD signal dependence on cerebral blood flow and oxygen consumption: The deoxyhemoglobin dilution model , 1999, Magnetic resonance in medicine.

[11]  G. Crelier,et al.  Linear coupling between cerebral blood flow and oxygen consumption in activated human cortex. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[12]  Alan C. Evans,et al.  Frequency-Dependent Changes in Cerebral Metabolic Rate of Oxygen during Activation of Human Visual Cortex , 1999, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[13]  P. Bandettini,et al.  QUIPSS II with thin‐slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling , 1999, Magnetic resonance in medicine.

[14]  Donald S. Williams,et al.  Tissue specific perfusion imaging using arterial spin labeling , 1994, NMR in biomedicine.

[15]  J. Ollinger Model-based scatter correction for fully 3D PET. , 1996, Physics in medicine and biology.

[16]  J W Belliveau,et al.  Borders of multiple visual areas in humans revealed by functional magnetic resonance imaging. , 1995, Science.

[17]  T. L. Davis,et al.  Calibrated functional MRI: mapping the dynamics of oxidative metabolism. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[18]  M. Blinkenberg,et al.  Regional Differences in the CBF and BOLD Responses to Hypercapnia: A Combined PET and fMRI Study , 2000, NeuroImage.

[19]  S G Kim,et al.  Perfusion imaging by a flow‐sensitive alternating inversion recovery (Fair) technique: Application to functional brain imaging , 1997, Magnetic resonance in medicine.

[20]  P. Johannsen,et al.  Cerebral Blood Flow Measurements by Magnetic Resonance Imaging Bolus Tracking: Comparison with [15O]H2O Positron Emission Tomography in Humans , 1998, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[21]  Gary H. Glover,et al.  Changes of Cerebral Blood Flow, Oxygenation, and Oxidative Metabolism during Graded Motor Activation , 2002, NeuroImage.

[22]  S Warach,et al.  A general kinetic model for quantitative perfusion imaging with arterial spin labeling , 1998, Magnetic resonance in medicine.

[23]  S C Strother,et al.  Comparison of matched BOLD and FAIR 4.0T-fMRI with [15O]water PET brain volumes. , 1999, Medical physics.

[24]  Jeff Duyn,et al.  H215O PET validation of steady‐state arterial spin tagging cerebral blood flow measurements in humans , 2000, Magnetic resonance in medicine.

[25]  Spatially‐confined arterial spin‐labeling with FAIR , 2005, Journal of magnetic resonance imaging : JMRI.

[26]  P ? ? ? ? ? ? ? % ? ? ? ? , 1991 .

[27]  Alan C. Evans,et al.  Anatomical mapping of functional activation in stereotactic coordinate space , 1992, NeuroImage.

[28]  Jack L. Lancaster,et al.  CBF changes during brain activation: fMRI vs. PET , 2004, NeuroImage.

[29]  R. Knight,et al.  Arterial spin labeling: Validity testing and comparison studies , 2005, Journal of magnetic resonance imaging : JMRI.

[30]  G. Crelier,et al.  Stimulus-Dependent BOLD and Perfusion Dynamics in Human V1 , 1999, NeuroImage.

[31]  Jan M Warnking,et al.  Bandwidth‐modulated adiabatic RF pulses for uniform selective saturation and inversion , 2004, Magnetic resonance in medicine.

[32]  W. Lin,et al.  Quantitative measurements of cerebral blood flow in patients with unilateral carotid artery occlusion: A PET and MR study , 2001, Journal of magnetic resonance imaging : JMRI.

[33]  G. Glover,et al.  A FAIR Study of Motor Cortex Activation under Normo- and Hypercapnia Induced by Breath Challenge , 1999, NeuroImage.

[34]  Alan C. Evans,et al.  The application of a masked orbiting transmission source for attenuation correction in PET. , 1989, Journal of Nuclear Medicine.

[35]  J. Mazziotta,et al.  Rapid Automated Algorithm for Aligning and Reslicing PET Images , 1992, Journal of computer assisted tomography.

[36]  David L. Thomas,et al.  Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques , 1999, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[37]  Brian N. Pasley,et al.  Analysis of oxygen metabolism implies a neural origin for the negative BOLD response in human visual cortex , 2007, NeuroImage.

[38]  D. Collins,et al.  Automatic 3D Intersubject Registration of MR Volumetric Data in Standardized Talairach Space , 1994, Journal of computer assisted tomography.

[39]  R. Buxton,et al.  Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling , 1997, NMR in biomedicine.

[40]  Jean Gotman,et al.  Hemodynamic and metabolic responses to activation, deactivation and epileptic discharges , 2005, NeuroImage.

[41]  Edward J. Hoffman,et al.  A study of data loss and mispositioning due to pileup in 2-D detectors in PET , 1990 .

[42]  Timothy J Carroll,et al.  Absolute Quantification of Cerebral Blood Flow with Magnetic Resonance, Reproducibility of the Method, and Comparison with H215O Positron Emission Tomography , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[43]  L O Hall,et al.  Review of MR image segmentation techniques using pattern recognition. , 1993, Medical physics.

[44]  Jan M Warnking,et al.  Reducing contamination while closing the gap: BASSI RF pulses in PASL , 2006, Magnetic resonance in medicine.

[45]  K Minematsu,et al.  Radioactive microsphere validation of a volume localized continuous saturation perfusion measurement , 1994, Magnetic resonance in medicine.