Blood speed imaging with an intraluminal array

In applications in which Doppler processing is not possible, such as side-looking intravascular imaging systems, decorrelation methods can be used to estimate blood speed. Here, a method is presented measuring relative blood speed using an FIR filter bank to estimate temporal decorrelation rates. It can be implemented in a modern commercially available ultrasound imaging system with no additional hardware. Both simulations and experiments using an intraluminal scanner appropriate for coronary artery applications have tested the system. In this study, the FIR filter bank is contrasted with previous methods, and its utility is further demonstrated with real-time color flow images from a pig model.

[1]  N Bom,et al.  Images in cardiovascular medicine. Simultaneous morphological and functional assessment of a renal artery stent intervention with intravascular ultrasound. , 1998, Circulation.

[2]  M. O'Donnell,et al.  Synthetic phased arrays for intraluminal imaging of coronary arteries , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  G. Trahey,et al.  Angle Independent Ultrasonic Detection of Blood Flow , 1987, IEEE Transactions on Biomedical Engineering.

[4]  W.D. O'Brien,et al.  Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-a review , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  N. Bom,et al.  Temporal correlation of blood scattering signals from intravascular ultrasound , 1995, 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium.

[6]  J.R. Crowe,et al.  Coronary artery flow imaging with an intraluminal array , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[7]  Jeffrey W. Eberhard,et al.  A New Time Domain Technique for Velocity Measurements Using Doppler Ultrasound , 1985, IEEE Transactions on Biomedical Engineering.

[8]  P.W. Serruys,et al.  In vivo validation of blood flow estimation using the decorrelation of radiofrequency intravascular echo signals , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[9]  D. Baim,et al.  Defining coronary restenosis. Newer clinical and angiographic paradigms. , 1993, Circulation.

[10]  N Bom,et al.  Blood flow imaging and volume flow quantitation with intravascular ultrasound. , 1998, Ultrasound in medicine & biology.

[11]  V. L. Newhouse,et al.  Theory of Ultrasound Doppler-Spectra Velocimetry for Arbitrary Beam and Flow Configurations , 1986, IEEE 1986 Ultrasonics Symposium.

[12]  L. Hillis,et al.  Efficacy and safety of coronary balloon angioplasty and directional atherectomy. , 1990, Circulation.

[13]  O. Bonnefous,et al.  A New Velocity Estimator for Color Flow Mapping , 1986, IEEE 1986 Ultrasonics Symposium.

[14]  S. Ellis,et al.  Advances in coronary angioplasty: Endovascular stents , 1990 .

[15]  C. Kasai,et al.  Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique , 1985, IEEE 1985 Ultrasonics Symposium.

[16]  A. Heimdal,et al.  Vessel wall detection and blood noise reduction in intravascular ultrasound imaging , 1994, 1994 Proceedings of IEEE Ultrasonics Symposium.

[17]  D.N. Stephens,et al.  Synthetic phased array imaging of coronary arteries with an intraluminal array , 1995, 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium.

[18]  J. Bittl Directional coronary atherectomy versus balloon angioplasty. , 1993, The New England journal of medicine.

[19]  T. Arts,et al.  Comparison of the performance of the RF cross correlation and Doppler autocorrelation technique to estimate the mean velocity of simulated ultrasound signals. , 1993, Ultrasound in medicine & biology.

[20]  W. O’Brien,et al.  Flow velocity profile via time-domain correlation: error analysis and computer simulation , 1990, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.