High-resolution dose–response screening using droplet-based microfluidics

A critical early step in drug discovery is the screening of a chemical library. Typically, promising compounds are identified in a primary screen and then more fully characterized in a dose–response analysis with 7–10 data points per compound. Here, we describe a robust microfluidic approach that increases the number of data points to approximately 10,000 per compound. The system exploits Taylor–Aris dispersion to create concentration gradients, which are then segmented into picoliter microreactors by droplet-based microfluidics. The large number of data points results in IC50 values that are highly precise (± 2.40% at 95% confidence) and highly reproducible (CV = 2.45%, n = 16). In addition, the high resolution of the data reveals complex dose–response relationships unambiguously. We used this system to screen a chemical library of 704 compounds against protein tyrosine phosphatase 1B, a diabetes, obesity, and cancer target. We identified a number of novel inhibitors, the most potent being sodium cefsulodine, which has an IC50 of 27 ± 0.83 μM.

[1]  A. deMello,et al.  A microdroplet dilutor for high-throughput screening. , 2011, Nature chemistry.

[2]  Ying Zhu,et al.  Automated microfluidic screening assay platform based on DropLab. , 2010, Analytical chemistry.

[3]  R. Bostwick,et al.  Advances in functional assays for high-throughput screening of ion channels targets , 2010, Expert opinion on drug discovery.

[4]  A. Theberge,et al.  Microdroplets in microfluidics: an evolving platform for discoveries in chemistry and biology. , 2010, Angewandte Chemie.

[5]  S. Yip,et al.  PTP1B: a double agent in metabolism and oncogenesis. , 2010, Trends in biochemical sciences.

[6]  D. Moras,et al.  Quantitative cell-based reporter gene assays using droplet-based microfluidics. , 2010, Chemistry & biology.

[7]  Jenifer Clausell-Tormos,et al.  An automated two-phase microfluidic system for kinetic analyses and the screening of compound libraries. , 2010, Lab on a chip.

[8]  Wilhelm T S Huck,et al.  Generation of picoliter droplets with defined contents and concentration gradients from the separation of chemical mixtures. , 2010, Analytical chemistry.

[9]  A. Combs Recent advances in the discovery of competitive protein tyrosine phosphatase 1B inhibitors for the treatment of diabetes, obesity, and cancer. , 2010, Journal of medicinal chemistry.

[10]  Youngeun Kim,et al.  2-layer based microfluidic concentration generator by hybrid serial and volumetric dilutions , 2010, Biomedical microdevices.

[11]  A. deMello,et al.  Droplet-based compartmentalization of chemically separated components in two-dimensional separations. , 2009, Chemical communications.

[12]  Lorenz M Mayr,et al.  Novel trends in high-throughput screening. , 2009, Current opinion in pharmacology.

[13]  N. Perrimon,et al.  Droplet microfluidic technology for single-cell high-throughput screening , 2009, Proceedings of the National Academy of Sciences.

[14]  Teck Chuan Lim,et al.  A microfluidic 3D hepatocyte chip for drug toxicity testing. , 2009, Lab on a chip.

[15]  Luis F. Olguin,et al.  Simultaneous measurement of reactions in microdroplets filled by concentration gradients. , 2009, Lab on a chip.

[16]  A. Griffiths,et al.  Reliable microfluidic on-chip incubation of droplets in delay-lines. , 2009, Lab on a chip.

[17]  S. Rhee,et al.  Multicompartmented microfluidic device for characterization of dose-dependent cadmium cytotoxicity in BALB/3T3 fibroblast cells , 2009, Biomedical microdevices.

[18]  Yiqiong Zhao,et al.  Compartmentalization of chemically separated components into droplets. , 2009, Angewandte Chemie.

[19]  Helene Andersson-Svahn,et al.  Detection and analysis of low-abundance cell-surface biomarkers using enzymatic amplification in microfluidic droplets. , 2009, Angewandte Chemie.

[20]  David S. W. Lim,et al.  Simultaneous generation of multiple aqueous droplets in a microfluidic device. , 2008, Analytica chimica acta.

[21]  A. Ahluwalia,et al.  A microfluidic gradient maker for toxicity testing of bupivacaine and lidocaine. , 2008, Toxicology in vitro : an international journal published in association with BIBRA.

[22]  E. Calabrese Hormesis and medicine. , 2008, British journal of clinical pharmacology.

[23]  Sam Michael,et al.  A robotic platform for quantitative high-throughput screening. , 2008, Assay and drug development technologies.

[24]  J. S. Johnson,et al.  Biocompatible surfactants for water-in-fluorocarbon emulsions. , 2008, Lab on a chip.

[25]  Scott D. Taylor,et al.  A re-examination of the difluoromethylenesulfonic acid group as a phosphotyrosine mimic for PTP1B inhibition. , 2008, Bioorganic & medicinal chemistry.

[26]  Christoph A. Merten,et al.  Droplet-based microfluidic platforms for the encapsulation and screening of Mammalian cells and multicellular organisms. , 2008, Chemistry & biology.

[27]  Sheng Zhang,et al.  PTP1B as a drug target: recent developments in PTP1B inhibitor discovery. , 2007, Drug discovery today.

[28]  Garry P Nolan,et al.  What's wrong with drug screening today. , 2007, Nature chemical biology.

[29]  Paul Yager,et al.  High-throughput screening of enzyme inhibition using an inhibitor gradient generated in a microchannel. , 2007, Lab on a chip.

[30]  Brian K Shoichet,et al.  Interpreting steep dose-response curves in early inhibitor discovery. , 2006, Journal of medicinal chemistry.

[31]  Adam Yasgar,et al.  Quantitative high-throughput screening: a titration-based approach that efficiently identifies biological activities in large chemical libraries. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[32]  Thomas R Downs,et al.  1,2,3,4-Tetrahydroisoquinolinyl sulfamic acids as phosphatase PTP1B inhibitors. , 2006, Bioorganic & medicinal chemistry letters.

[33]  Robert Nadon,et al.  Statistical practice in high-throughput screening data analysis , 2006, Nature Biotechnology.

[34]  Nam-Trung Nguyen,et al.  Mixing in microchannels based on hydrodynamic focusing and time-interleaved segmentation: modelling and experiment. , 2005, Lab on a chip.

[35]  S. Quake,et al.  Microfluidics: Fluid physics at the nanoliter scale , 2005 .

[36]  J. Carbeck,et al.  Diffusivity of solutes measured in glass capillaries using Taylor's analysis of dispersion and a commercial CE instrument. , 2005, Analytical chemistry.

[37]  Hans Lehrach,et al.  Cell-free protein expression and functional assay in nanowell chip format. , 2004, Analytical chemistry.

[38]  Helen Song,et al.  Millisecond kinetics on a microfluidic chip using nanoliters of reagents. , 2003, Journal of the American Chemical Society.

[39]  Alan Dove,et al.  Screening for content—the evolution of high throughput , 2003, Nature Biotechnology.

[40]  Andreas Sewing,et al.  Measuring intracellular calcium fluxes in high throughput mode. , 2003, Combinatorial chemistry & high throughput screening.

[41]  H. Stone,et al.  Formation of dispersions using “flow focusing” in microchannels , 2003 .

[42]  S. Vajjhala,et al.  A prototype microfluidic platform for miniaturization and automation of serial dilution and dose-response assays. , 2002, Assay and drug development technologies.

[43]  J. Ermolieff,et al.  Protein tyrosine phosphatase 1B inhibitors for diabetes , 2002, Nature Reviews Drug Discovery.

[44]  D. Lawrence,et al.  Acquisition of a Specific and Potent PTP1B Inhibitor from a Novel Combinatorial Library and Screening Procedure* , 2001, The Journal of Biological Chemistry.

[45]  R. Peters,et al.  Permeability of single nuclear pores. , 1999, Biophysical journal.

[46]  Thomas D. Y. Chung,et al.  A Simple Statistical Parameter for Use in Evaluation and Validation of High Throughput Screening Assays , 1999, Journal of biomolecular screening.

[47]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[48]  Y. Keng,et al.  Suramin Is an Active Site-directed, Reversible, and Tight-binding Inhibitor of Protein-tyrosine Phosphatases* , 1998, The Journal of Biological Chemistry.

[49]  P. Righetti,et al.  Use of Taylor-Aris Dispersion for Measurement of a Solute Diffusion Coefficient in Thin Capillaries , 1994, Science.

[50]  R. Aris On the dispersion of a solute in a fluid flowing through a tube , 1956, Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences.

[51]  G. Taylor Conditions under which dispersion of a solute in a stream of solvent can be used to measure molecular diffusion , 1954, Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences.

[52]  Geoffrey Ingram Taylor,et al.  The dispersion of matter in turbulent flow through a pipe , 1954, Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences.

[53]  G. Taylor Dispersion of soluble matter in solvent flowing slowly through a tube , 1953, Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences.

[54]  A. Griffiths On the Movement of a Coloured Index along a Capillary Tube, and its Application to the Measurement of the Circulation of Water in a Closed Circuit , 1910 .

[55]  Petr Kuzmic,et al.  Practical Robust Fit of Enzyme Inhibition Data , 2004, Numerical Computer Methods, Part D.

[56]  A. Hill,et al.  The possible effects of the aggregation of the molecules of haemoglobin on its dissociation curves , 1910 .